96% AFUE Downflow/Horizontal Gas Furnace GC9S96 Series, Single-Stage, Multi-Speed, ECM L60-515
96% AFUE Downflow/Horizontal Gas Furnace GC9S96 Series, Single-Stage, Multi-Speed, ECM
AFUE: 96.0%; Configuration: Downflow/Horizontal; BtuH Input: 120,000; BtuH Output: 114,000; Nom. Tons: 5; Nom. CFM: 2,000; CFM @ 0.5" ESP: 1,602; Min. Circuit Amps: 16.9; Vent Size: 3"; Motor Type: ECM; Width: 24-1/2"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 156; Stages: Single-Stage; LoNox: No;
Brand: Goodman Mfg #: GC9S961205DN

96% AFUE Dowflow/Horizontal Gas Furnace GC9C96 Series, Two-Stage, Multi-Speed ECM L60-527
96% AFUE Dowflow/Horizontal Gas Furnace GC9C96 Series, Two-Stage, Multi-Speed ECM
AFUE: 96.0%; Configuration: Downflow/Horizontal; BtuH Input: 80,000; BtuH Output: 76,800; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,295; Min. Circuit Amps: 8.0; Vent Size: 2"-3"; Motor Type: ECM; Width: 17-1/2"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 118; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GC9C960803BN

80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX L60-450
80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 60,000; BtuH Output: 48,000; Nom. Tons: 4; Nom. CFM: 1,600; CFM @ 0.5" ESP: 1,631; Min. Circuit Amps: 12.45; Vent Size: 4"; Motor Type: ECM; Width: 17-1/2"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 108; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9S800604BX

Heat Pump 15.2 SEER2, Single-Phase, 4 Ton, R410A B65-703
Heat Pump 15.2 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 15.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH504810

80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX L60-444
80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 40,000; BtuH Output: 32,000; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,314; Min. Circuit Amps: 8.7; Vent Size: 4"; Motor Type: ECM; Width: 14"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 86; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9S800403AX

80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX L60-458
80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 80,000; BtuH Output: 64,000; Nom. Tons: 5; Nom. CFM: 2,000; CFM @ 0.5" ESP: 1,973; Min. Circuit Amps: 12.45; Vent Size: 4"; Motor Type: ECM; Width: 21"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 132; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9S800805CX

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A B66-331
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB406010

80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX L60-454
80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 80,000; BtuH Output: 64,000; Nom. Tons: 4; Nom. CFM: 1,600; CFM @ 0.5" ESP: 1,708; Min. Circuit Amps: 12.45; Vent Size: 4"; Motor Type: ECM; Width: 17-1/2"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 120; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9S800804BX

80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX L60-446
80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 60,000; BtuH Output: 48,000; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,354; Min. Circuit Amps: 8.7; Vent Size: 4"; Motor Type: ECM; Width: 14"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 90; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9S800603AX

80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX L60-460
80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 100,000; BtuH Output: 80,000; Nom. Tons: 5; Nom. CFM: 2,000; CFM @ 0.5" ESP: 1,981; Min. Circuit Amps: 12.45; Vent Size: 4"; Motor Type: ECM; Width: 21"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 132; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9S801005CX

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 4 Ton, R410A B65-954
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 14.3; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB404810

96% AFUE Dowflow/Horizontal Gas Furnace GC9C96 Series, Two-Stage, Multi-Speed ECM L60-528
96% AFUE Dowflow/Horizontal Gas Furnace GC9C96 Series, Two-Stage, Multi-Speed ECM
AFUE: 96.0%; Configuration: Downflow/Horizontal; BtuH Input: 100,000; BtuH Output: 96,000; Nom. Tons: 5; Nom. CFM: 2,000; CFM @ 0.5" ESP: 1,931; Min. Circuit Amps: 13.3; Vent Size: 2"-3"; Motor Type: ECM; Width: 21"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 140; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GC9C961005CN

96% AFUE Upflow/Horizontal Gas Furnace GM9C96 Series, Two-Stage, Multi-Speed ECM L60-516
96% AFUE Upflow/Horizontal Gas Furnace GM9C96 Series, Two-Stage, Multi-Speed ECM
AFUE: 96.0%; Configuration: Upflow/Horizontal; BtuH Input: 30,000; BtuH Output: 28,800; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,128; Min. Circuit Amps: 8.6; Vent Size: 2"-3"; Motor Type: ECM; Width: 14"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 106; Stages: Two-Stage; LoNox: No;
Brand: Goodman Mfg #: GM9C960303AN

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A B65-723
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A
SEER2: 17.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 24.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 216; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC703610

80% AFUE Downflow/Horizontal Gas Furnace GC9C80 Series, Two-Stage, Multi-Speed, LoNOX L60-493
80% AFUE Downflow/Horizontal Gas Furnace GC9C80 Series, Two-Stage, Multi-Speed, LoNOX
AFUE: 80.0%; Configuration: Downflow/Horizontal; BtuH Input: 80,000; BtuH Output: 64,000; Nom. Tons: 4; Nom. CFM: 1,600; CFM @ 0.5" ESP: 1,491; Min. Circuit Amps: 12.45; Vent Size: 4"; Motor Type: ECM; Width: 17-1/2"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 121; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GC9C800804BX

80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX L60-448
80% AFUE Upflow/Horizontal Gas Furnace GM9S80 Series, Multi-Speed, ECM, LoNOX
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 60,000; BtuH Output: 48,000; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,387; Min. Circuit Amps: 8.7; Vent Size: 4"; Motor Type: ECM; Width: 17-1/2"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 100; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9S800603BX

96% AFUE Dowflow/Horizontal Gas Furnace GC9C96 Series, Two-Stage, Multi-Speed ECM L60-525
96% AFUE Dowflow/Horizontal Gas Furnace GC9C96 Series, Two-Stage, Multi-Speed ECM
AFUE: 96.0%; Configuration: Downflow/Horizontal; BtuH Input: 40,000; BtuH Output: 38,400; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,276; Min. Circuit Amps: 8.0; Vent Size: 2"-3"; Motor Type: ECM; Width: 17-1/2"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 112; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GC9C960403BN

80% AFUE Downflow/Horizontal Gas Furnace GC9C80 Series, Two-Stage, Multi-Speed, LoNOX L60-491
80% AFUE Downflow/Horizontal Gas Furnace GC9C80 Series, Two-Stage, Multi-Speed, LoNOX
AFUE: 80.0%; Configuration: Downflow/Horizontal; BtuH Input: 60,000; BtuH Output: 48,000; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,289; Min. Circuit Amps: 8.7; Vent Size: 4"; Motor Type: ECM; Width: 14"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 107; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GC9C800603AX

80% AFUE Downflow/Horizontal Gas Furnace GC9C80 Series, Two-Stage, Multi-Speed, LoNOX L60-492
80% AFUE Downflow/Horizontal Gas Furnace GC9C80 Series, Two-Stage, Multi-Speed, LoNOX
AFUE: 80.0%; Configuration: Downflow/Horizontal; BtuH Input: 60,000; BtuH Output: 48,000; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,322; Min. Circuit Amps: 8.7; Vent Size: 4"; Motor Type: ECM; Width: 17-1/2"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 107; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GC9C800603BX

80% AFUE Upflow/Horizontal Gas Furnace GM9C80 Series, Two-Stage, Multi-Speed L60-488
80% AFUE Upflow/Horizontal Gas Furnace GM9C80 Series, Two-Stage, Multi-Speed
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 80,000; BtuH Output: 64,000; Nom. Tons: 5; Nom. CFM: 2,000; CFM @ 0.5" ESP: 2,020; Min. Circuit Amps: 15.32; Vent Size: 4"; Motor Type: ECM; Width: 24-1/2"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 129; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9C800805DX

80% AFUE Upflow/Horizontal Gas Furnace GM9C80 Series, Two-Stage, Multi-Speed L60-483
80% AFUE Upflow/Horizontal Gas Furnace GM9C80 Series, Two-Stage, Multi-Speed
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 60,000; BtuH Output: 48,000; Nom. Tons: 3; Nom. CFM: 1,200; CFM @ 0.5" ESP: 1,387; Min. Circuit Amps: 8.7; Vent Size: 4"; Motor Type: ECM; Width: 17-1/2"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 107; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9C800603BX

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-704
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 30.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH506010

92% AFUE  Upflow/Horizontal Gas Furnace GM9S92 Series, Single-Stage, Multi-Speed, ECM L60-500
92% AFUE Upflow/Horizontal Gas Furnace GM9S92 Series, Single-Stage, Multi-Speed, ECM
AFUE: 92.0%; Configuration: Upflow/Horizontal; BtuH Input: 80,000; BtuH Output: 73,680; Nom. Tons: 5; Nom. CFM: 2,000; CFM @ 0.5" ESP: 1,644; Min. Circuit Amps: 16.9; Vent Size: 2"-3"; Motor Type: ECM; Width: 21"; Height: 34-1/2"; Depth: 28-7/8"; Wt. Lbs.: 140; Stages: Single-Stage; LoNox: No;
Brand: Goodman Mfg #: GM9S920805CN

80% AFUE Upflow/Horizontal Gas Furnace GM9C80 Series, Two-Stage, Multi-Speed L60-486
80% AFUE Upflow/Horizontal Gas Furnace GM9C80 Series, Two-Stage, Multi-Speed
AFUE: 80.0%; Configuration: Upflow/Horizontal; BtuH Input: 80,000; BtuH Output: 64,000; Nom. Tons: 4; Nom. CFM: 1,600; CFM @ 0.5" ESP: 1,695; Min. Circuit Amps: 12.45; Vent Size: 4"; Motor Type: ECM; Width: 21"; Height: 33-3/8"; Depth: 28"; Wt. Lbs.: 129; Stages: Two-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GM9C800804CX