16 Results

5, 4, 2, 13 to 13.2, Goodman

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-611
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.96; Min. Circuit Amps: 13.5; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160241

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-609
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 49,500; BtuH Heating Input: 51,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.76; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180481

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-613
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 5.16; Min. Circuit Amps: 26.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160481

Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A B77-552
Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.94; Min. Circuit Amps: 14.7; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-603
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 32-1/2"; Depth: 29-1/4"; Wt. Lbs.: 180; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC160241

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-556
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.75; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160481

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-602
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 326; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180601

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-601
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 298; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-605
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 263; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B60-820
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 132; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B60-824
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.7; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX16S481

Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Horizontal B76-931
Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 16; EER: 13; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 875; Min. Circuit Amps: 21.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1624H41

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B91-226
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.75; COP: 4.54; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: DSZC160481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-217
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 181; OEM TXV: B18-099;
Brand: Goodman Mfg #: DSXC160241

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-187
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 17; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.96; Min. Circuit Amps: 13.5; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160241SUB