94 Results

1, 3-1/2, 2, Goodman

Dual Fuel Packaged Unit 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, 8.0 HSPF B77-163
Dual Fuel Packaged Unit 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, 8.0 HSPF
SEER: 14; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 60,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 21.2; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 420;
Brand: Goodman Mfg #: GPD1424060M41

Single Packaged Heat Pump GPHM5 Series, 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A, Multi-Position B66-351
Single Packaged Heat Pump GPHM5 Series, 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A, Multi-Position
SEER2: 15.2; EER2: 11.4; Nom. Tons: 3-1/2; BtuH Cooling: 40,500; BtuH Heating Input: 38,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.8; COP: 3.6; Nom. CFM: 1,300; Min. Circuit Amps: 31.7; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 492;
Brand: Goodman Mfg #: GPHM54241

Single Packaged Air Conditioner 15 SEER, Single-Phase, 3-1/2 Ton, R410A, Horizontal B77-200
Single Packaged Air Conditioner 15 SEER, Single-Phase, 3-1/2 Ton, R410A, Horizontal
SEER: 15; EER: 12; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,300; Min. Circuit Amps: 28.0; Max. Fuse Size: 45; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 350;
Brand: Goodman Mfg #: GPC1542H41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B75-672
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 22,800; BtuH Heating Input: 60,000; BtuH Heating Output: 47,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 19.5; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 370;
Brand: Goodman Mfg #: GPG1624060M41

Single Packaged Heat Pump GPHM5 Series, 15.2 SEER2, Single-Phase, 2 Ton, R410A, Multi-Position B66-348
Single Packaged Heat Pump GPHM5 Series, 15.2 SEER2, Single-Phase, 2 Ton, R410A, Multi-Position
SEER2: 15.2; EER2: 11.4; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.68; Nom. CFM: 850; Min. Circuit Amps: 18.7; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 376;
Brand: Goodman Mfg #: GPHM52441

Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx B64-920
Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 40,000; BtuH Heating Output: 31,000; Volts: 208/230; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 14.4; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 412;
Brand: Goodman Mfg #: GPU1424040M41

Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, 81% AFUE, R410A, Ultra LowNOx B64-923
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, 81% AFUE, R410A, Ultra LowNOx
SEER: 14; EER: 11; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; BtuH Heating Input: 80,000; BtuH Heating Output: 64,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,300; Min. Circuit Amps: 29.2; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 523;
Brand: Goodman Mfg #: GPU1442080M41

Single Packaged Air Conditioner 15 SEER, Single-Phase, 2 Ton, R410A, Horizontal B77-197
Single Packaged Air Conditioner 15 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 15; EER: 12; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 875; Min. Circuit Amps: 15.0; Max. Fuse Size: 20; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 300;
Brand: Goodman Mfg #: GPC1524H41

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 3.5 Ton, R410A B91-674
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 3.5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 171; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130421

Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 2T, R410A, Horizontal B66-115
Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 2T, R410A, Horizontal
SEER2: 15.2; EER2: 11.4; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.73; Nom. CFM: 875; Min. Circuit Amps: 21.3; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPHH52441

Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 3.5T, R410A, Horizontal B66-118
Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 3.5T, R410A, Horizontal
SEER2: 15.2; EER2: 11.4; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 40,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.54; Nom. CFM: 1,300; Min. Circuit Amps: 30.6; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPHH54241

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-224
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.74; Min. Circuit Amps: 15.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth:…
Brand: Goodman Mfg #: DSZC160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-217
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 181; OEM TXV: B18-099;
Brand: Goodman Mfg #: DSXC160241

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-678
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.8; Max. Fuse Size: 36; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 189; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX140431

Heat Pump GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A B75-928
Heat Pump GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.57; Min. Circuit Amps: 14.6; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth:…
Brand: Goodman Mfg #: VSZ140241

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A B75-921
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX140241

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A B61-812
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 2.5 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 113; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX130241

Heat Pump GMC Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-931
Heat Pump GMC Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.44; Min. Circuit Amps: 22; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: VSZ140421

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-924
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.8; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 189; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX140421

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-187
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 17; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.96; Min. Circuit Amps: 13.5; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160241SUB

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A B76-583
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 136; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX140251

Heat Pump GMC Series, 13 SEER, Single-Phase, 3.5 Ton, R410A B91-681
Heat Pump GMC Series, 13 SEER, Single-Phase, 3.5 Ton, R410A
SEER: 13; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 38-3/4"; Depth: 29"; Wt. Lbs.:…
Brand: Goodman Mfg #: VSZ130421
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare