215 Results

5, 2, Goodman

96% AFUE Upflow/Horizontal Gas Furnace GMES96 Series, Single-Stage, Multi-Speed, ECM, Ultra LoNOx L95-230
96% AFUE Upflow/Horizontal Gas Furnace GMES96 Series, Single-Stage, Multi-Speed, ECM, Ultra LoNOx
AFUE: 96.0%; Configuration: Upflow/Horizontal; BtuH Input: 80,000; BtuH Output: 76,800; Nom. Tons: 5; Nom. CFM: 2,000; CFM @ 0.5" ESP: 2,149; Min. Circuit Amps: 16.1; Vent Size: 2" - 3"; Motor Type: ECM; Width: 21"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 145; Stages: Single-Stage; LoNox: Yes;
Brand: Goodman Mfg #: GMES960805CU

96% AFUE Upflow/Horizontal Gas Furnace VMES96 Series, Single-Stage, Multi-Speed, ECM L95-479
96% AFUE Upflow/Horizontal Gas Furnace VMES96 Series, Single-Stage, Multi-Speed, ECM
AFUE: 96.0%; Configuration: Upflow/Horizontal; BtuH Input: 100,000; BtuH Output: 96,100; Nom. Tons: 5; Nom. CFM: 2000; Min. Circuit Amps: 13.7; Vent Size: 4"; Motor Type: ECM; Width: 21"; Height: 34-1/2"; Depth: 28-7/8"; Wt. Lbs.: 140; Stages: Single-Stage; LoNox: No;
Brand: Goodman Mfg #: VMES961005CN

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B98-350
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130601

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B73-806
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 211; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130611

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A B66-581
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 13.4; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 125; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN3N2410

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A B66-586
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.4; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 227; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN3N6010

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-966
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; Nom. Tons: 5; BtuH Cooling: 55,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN406010

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-579
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140251

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A B75-912
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140601

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-961
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 138; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-950
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 169; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-957
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXM402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-955
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 305; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB406010

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A B65-680
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXH502410

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-685
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH506010

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B73-974
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 142; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B60-820
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 132; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B74-721
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 57,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 291; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160611

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-603
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 32-1/2"; Depth: 29-1/4"; Wt. Lbs.: 180; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-217
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 181; OEM TXV: B18-099;
Brand: Goodman Mfg #: DSXC160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare