496 Results

14, Training, Testing, Tools & Training, Test Instruments, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V B64-211
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 20.2; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 460;
Brand: Coleman Mfg #: PCG4B481253X4

Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A B64-281
Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.28; Min. Circuit Amps: 19.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth:…
Brand: Goodman Mfg #: GSZ140361

Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1-1/2 Ton, R410A B63-653
Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1-1/2 Ton, R410A
Nom. Tons: 1-1/2; SEER: 14; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 29-1/2"; Height: 23"; Depth: 22"; Wt. Lbs.: 134;
Brand: First Co Mfg #: 18WCX14-CB

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V B64-216
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 7.6; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 379;
Brand: Coleman Mfg #: PCG4A360754X4

Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A B64-152
Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 16.1; Max. Fuse Size: 20; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 350;
Brand: Coleman Mfg #: PCE4A3634

Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, Multi-Position B79-260
Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 46,500; Volts: 208/230; Phase: Three; Motor Type: EEM; Nom. CFM: 1,600; Min. Circuit Amps: 23.2; Max. Fuse Size: 35; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 435; BtuH Heating Input: 48,000;
Brand: Daikin Mfg #: DP14CM4843

Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-917
Heat Pump 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.44; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: GSZ140421

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only B77-430
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC4B4821S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-193
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,165; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 359;
Brand: Coleman Mfg #: PCG4A360502X4

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B75-918
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.72; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: GSZ140481

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B75-919
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140601

Heat Pump 14 SEER, Single-Phase, 1-1/2 Ton, R410A B75-913
Heat Pump 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.6; Min. Circuit Amps: 8.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140181

Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A B78-392
Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 13; Nom. Tons: 2-1/2; BtuH Cooling: 28,800; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.06; Min. Circuit Amps: 18.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3021S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 460V B64-222
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 460V
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 12.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 475;
Brand: Coleman Mfg #: PCG4B601004X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 460V B64-223
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 460V
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 12.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PCG4B601254X4

Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, Multi-Position B79-259
Single Packaged Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 35,000; Volts: 208/230; Phase: Three; Motor Type: PSC; Nom. CFM: 1,200; Min. Circuit Amps: 18.2; Max. Fuse Size: 25; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 365; BtuH Heating Input: 36,000;
Brand: Daikin Mfg #: DP14CM3643

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southeast & Northern Region Only B61-255
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.3; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TC4B4222S

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B78-391
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.96; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TH4B2421S

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-661
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.25; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.66; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Coleman Mfg #: TH4B4822S

Single Packaged Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410A, Multi-Position B79-261
Single Packaged Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Three; Motor Type: EEM; Nom. CFM: 1,700; Min. Circuit Amps: 28.9; Max. Fuse Size: 40; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 445; BtuH Heating Input: 60,000;
Brand: Daikin Mfg #: DP14CM6043

Heat Pump LX Series, 14 SEER, Three-Phase, 2-1/2 Ton, R410A B79-359
Heat Pump LX Series, 14 SEER, Three-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 2-1/2; HSPF: 9.00; COP: 3.36; Min. Circuit Amps: 5.93; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 176;
Brand: Coleman Mfg #: THE30B41S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A B75-908
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX140301

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V B64-208
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,350; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 402;
Brand: Coleman Mfg #: PCG4A421003X4