66 Results

5, 4, 2-1/2, 12 to 12.8, Goodman, Daikin, Aspen Manufacturing, HVAC Equipment

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B73-975
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 149; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160301

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B75-681
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 155; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160311

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A B76-580
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX140311

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B73-978
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX160481

Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Multi-Position B77-257
Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; BtuH Heating Input: 28,400; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,050; Min. Circuit Amps: 22.2; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 385;
Brand: Goodman Mfg #: GPH1630M41

5 Ton Heat Pump 14 SEER 3 Phase 208/230V B79-505
5 Ton Heat Pump 14 SEER 3 Phase 208/230V
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,000; Volts: 208/230; Phase: Three; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 21.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/4"; Depth: 35-1/2";…
Brand: Daikin Mfg #: DZ14SA0603

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal B90-041
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 1,050; Min. Circuit Amps: 23.0; Max. Fuse Size: 35; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 350;
Brand: Goodman Mfg #: GPC1430H41

Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, Horizontal B90-044
Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 4; BtuH Cooling: 46,000; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 1,600; Min. Circuit Amps: 32.0; Max. Fuse Size: 50; Refrigerant: R410A; Width: 66"; Height: 38-1/2"; Depth: 33"; Wt. Lbs.: 365;
Brand: Goodman Mfg #: GPC1448H41

Heat Pump 14 SEER, Single-Phase, 2-1/2 Ton, R410A B79-086
Heat Pump 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2-1/2; BtuH Cooling: 28,000; BtuH Heating Input: 31,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.87; Min. Circuit Amps: 17.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8;…
Brand: Goodman Mfg #: GSZ140311

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, Horizontal B90-045
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 57,500; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 1,600; Min. Circuit Amps: 40.0; Max. Fuse Size: 60; Refrigerant: R410A; Width: 66"; Height: 35-1/2"; Depth: 33"; Wt. Lbs.: 370;
Brand: Goodman Mfg #: GPC1460H41

Single Packaged Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A, Multi-Position B77-260
Single Packaged Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 1,600; Min. Circuit Amps: 33.7; Refrigerant: R410A; Width: 47"; Height: 42-1/4"; Depth: 51"; Wt. Lbs.: 490;
Brand: Goodman Mfg #: GPH1648M41

4 Ton Heat Pump 14 SEER 3 Phase 208/230V B79-503
4 Ton Heat Pump 14 SEER 3 Phase 208/230V
SEER: 14; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 45,000; BtuH Heating Input: 44,500; Volts: 208/230; Phase: Three; HSPF: 9.0; COP: 4.72; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Width: 29"; Height: 34-1/4"; Depth: 29"; Wt. Lbs.: 235;
Brand: Daikin Mfg #: DZ14SA0483

5 Ton Heat Pump 14 SEER 3 Phase 460V B79-506
5 Ton Heat Pump 14 SEER 3 Phase 460V
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,000; Volts: 460; Phase: Three; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/4"; Depth: 35-1/2"; Wt.…
Brand: Daikin Mfg #: DZ14SA0604

Single Packaged Heat Pump 14 SEER, Single-Phase, 2.5 Ton, R410A, Horizontal B90-047
Single Packaged Heat Pump 14 SEER, Single-Phase, 2.5 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; BtuH Heating Input: 27,600; Volts: 208/230; Phase: Single; Motor Type: EEM; HSPF: 8.0; COP: 3.8; Nom. CFM: 950; Min. Circuit Amps: 23.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1430H41

Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal B76-932
Single Packaged Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal
SEER: 16; EER: 12.5; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; BtuH Heating Input: 27,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 1,050; Min. Circuit Amps: 23.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1630H41

4 Ton Heat Pump 14 SEER 3 Phase 460V B79-504
4 Ton Heat Pump 14 SEER 3 Phase 460V
EER: 12.5; Nom. Tons: 4; BtuH Cooling: 45,000; BtuH Heating Input: 44,500; Volts: 460; Phase: Three; HSPF: 9.0; COP: 4.72; Min. Circuit Amps: 8.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29"; Height: 34-1/4"; Depth: 29"; Wt. Lbs.: 234;
Brand: Daikin Mfg #: DZ14SA0484

Gas/Electric Packaged Air Conditioner Up to 17 IEER/13EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, High Heat B64-750
Gas/Electric Packaged Air Conditioner Up to 17 IEER/13EER, 81% Thermal Efficiency, Three-Phase, 5 Ton, R510A, High Heat
SEER: 16.5; EER: 12.1; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 140,000; BtuH Heating Output: 113,400; Volts: 460V; Phase: Three; Motor Type: Direct Drive; Nom. CFM: 2,000; Min. Circuit Amps: 16.4; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 655;
Brand: Daikin Mfg #: DRG0604DH00001S

Gas/Electric Packaged Air Conditioner 17 SEER/12.8 EER, 81% AFUE, Single-Phase, 4 Ton, R410A, Medium Heat B63-288
Gas/Electric Packaged Air Conditioner 17 SEER/12.8 EER, 81% AFUE, Single-Phase, 4 Ton, R410A, Medium Heat
SEER: 17.0; EER: 12.8; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 115,000; BtuH Heating Output: 93,200; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; Nom. CFM: 1,600; Min. Circuit Amps: 34.3; Refrigerant: R410A; Width: 74"; Height: 43-1/2"; Depth: 48-5/16"; Wt. Lbs.: 647;
Brand: Daikin Mfg #: DRG0481DM00001S

Single Packaged Air Conditioner 15 SEER/Up To 13 EER, Single-Phase, 5 Ton, R410A B77-175
Single Packaged Air Conditioner 15 SEER/Up To 13 EER, Single-Phase, 5 Ton, R410A
SEER: 15; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; Nom. CFM: 2,000; Min. Circuit Amps: 40.2; Refrigerant: R410A; Width: 74-1/16"; Height: 42-21/25"; Depth: 48-49/250"; Wt. Lbs.: 544;
Brand: Daikin Mfg #: DTC060XXX1DXXX

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2-1/2 Ton, 81% AFUE, R410A, Multi-Position B75-673
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2-1/2 Ton, 81% AFUE, R410A, Multi-Position
SEER: 15.5; EER: 12.0; Nom. Tons: 2-1/2; BtuH Cooling: 28,600; BtuH Heating Input: 80,000; BtuH Heating Output: 62,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 950; Min. Circuit Amps: 21.7; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 397;
Brand: Goodman Mfg #: GPG1630080M41