12 Results

18, 1, Goodman, Coleman, HVAC Equipment

Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-607
Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 5.65; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC180241

Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-608
Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 34,800; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 4.65; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC180361

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-609
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 49,500; BtuH Heating Input: 51,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.76; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180481

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A B64-414
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A
SEER: 18; EER: 10; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.4; Min. Circuit Amps: 23; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 37-3/8"; Height: 33"; Depth:…
Brand: Coleman Mfg #: HMH72B361S

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 4 Ton, R410A B64-415
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 18; EER: 10.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 3.34; Min. Circuit Amps: 36; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 37-3/8"; Height: 54-5/8";…
Brand: Coleman Mfg #: HMH72B481S

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-599
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 236; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC180241

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-600
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 238; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC180361

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-602
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 326; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180601

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-601
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 298; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180481

Echelon™ Heat Pump 18 SEER, Single-Phase, 2 Ton, R410A B75-599
Echelon™ Heat Pump 18 SEER, Single-Phase, 2 Ton, R410A
SEER: 18; EER: 14; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.8; COP: 4.0; Min. Circuit Amps: 17.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 34"; Height: 40"; Depth:…
Brand: Coleman Mfg #: HC8B024F4C

Echelon™ Heat Pump 18 SEER, Single-Phase, 5 Ton, R410A B75-602
Echelon™ Heat Pump 18 SEER, Single-Phase, 5 Ton, R410A
SEER: 18; EER: 12; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 3.86; Min. Circuit Amps: 36.9; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34"; Height: 40"; Depth:…
Brand: Coleman Mfg #: HC8B060F4C
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare