297 Results

5, 4, Coleman, HVAC Equipment

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 4 Ton, R410A B65-537
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 4; BtuH Cooling: 47,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 24; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-3/4"; Height: 33-1/4"; Depth: 35-1/4"; Wt. Lbs.: 210; OEM TXV: B19-659; OEM TXV for C…
Brand: Coleman Mfg #: TCE2B48S21S

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-538
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 30.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-3/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for C…
Brand: Coleman Mfg #: TCE2B60S21S

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A B79-687
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 20; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.6; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 43-1/4"; Depth: 38-1/4"; Wt. Lbs.: 264;
Brand: Coleman Mfg #: AC21B4821S

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-688
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2"; Depth: 38-1/4"; Wt. Lbs.: 270;
Brand: Coleman Mfg #: AC21B6021S

Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 4 Ton, R410A B73-602
Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34"; Height: 40"; Depth: 42-1/4"; Wt. Lbs.: 250; OEM TXV: B18-133;
Brand: Coleman Mfg #: AC6B048F4C

Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 5 Ton, R410A B71-663
Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34"; Height: 40"; Depth: 42-1/4"; Wt. Lbs.: 235; OEM TXV: B17-087;
Brand: Coleman Mfg #: AC6B060F3C

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A B60-667
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A
SEER: 19; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: AC19B4821S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A B60-668
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659;…
Brand: Coleman Mfg #: AC19B6021S

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 4 Ton, R410A B91-943
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 12.25; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 27.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240; OEM TXV: B19-659; OEM TXV for…
Brand: Coleman Mfg #: TCHD48S41S3

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 5 Ton, R410A B91-944
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 250; OEM TXV: B19-660; OEM TXV for…
Brand: Coleman Mfg #: TCHD60S41S3

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A B60-176
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE48S41S1

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A B77-418
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 28.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 165; OEM TXV: B19-659; OEM TXV…
Brand: Coleman Mfg #: TC3B4821S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A B66-461
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER2: 13.4; EER2: 11.00; Nom. Tons: 4; BtuH Cooling: 47,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-1/4"; Height: 33-1/4"; Depth: 35-1/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM TXV for X Series Coils: B19-659;
Brand: Coleman Mfg #: TCD2B48S21S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A, Fin Tube B79-332
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A, Fin Tube
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 210; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TF3B4821S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B62-070
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 29.1; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 190; OEM TXV: B19-660;…
Brand: Coleman Mfg #: TC3B6022S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B66-462
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER2: 13.4; EER2: 11.00; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: PSC; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for X Series Coils: B19-659;
Brand: Coleman Mfg #: TCD2B60S21S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A B79-354
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 4; Volts: 208/230; Phase: Three; Min. Circuit Amps: 18.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD48B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A B79-355
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 4; Volts: 460; Phase: Three; Min. Circuit Amps: 8.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-3/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD48B41S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-356
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.2; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-357
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 460; Phase: Three; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B41S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only B77-430
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC4B4821S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only B77-437
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TW4B4821S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Fin Tube, Southeast Region Only B77-445
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 256; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TF4B6021S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only B77-431
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TC4B6021S