21 Results

4, 3, Split Systems, Commercial, HVAC Equipment

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A B79-354
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 4; Volts: 208/230; Phase: Three; Min. Circuit Amps: 18.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD48B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-258
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 208/230; Phase: Three; Min. Circuit Amps: 14.34; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B32S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-259
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 460; Phase: Three; Min. Circuit Amps: 7.85; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B42S

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A B74-085
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.3; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 190;
Brand: Daikin Mfg #: DX13SA0483

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A B74-084
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 28-3/4"; Depth: 29"; Wt. Lbs.: 196;
Brand: Daikin Mfg #: DX13SA0363

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A B74-086
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.3; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 460; Phase: Three; Min. Circuit Amps: 8.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 189;
Brand: Daikin Mfg #: DX13SA0484

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A B78-971
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 460; Phase: Three; Min. Circuit Amps: 7.9; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 28-3/4"; Depth: 29"; Wt. Lbs.: 196;
Brand: Daikin Mfg #: DX13SA0364

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A B79-355
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 4; Volts: 460; Phase: Three; Min. Circuit Amps: 8.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-3/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD48B41S

Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A B61-263
Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 3; HSPF: 8.55; COP: 3.48; Min. Circuit Amps: 12.58; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE36B32S

Heat Pump LX Series, 14 SEER, Three-Phase, 4 Ton, R410A B79-364
Heat Pump LX Series, 14 SEER, Three-Phase, 4 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 4; HSPF: 9.00; COP: 3.58; Min. Circuit Amps: 18.42; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 235;
Brand: Coleman Mfg #: THE48B31S

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 208/230V B91-946
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 208/230V
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: 3; Min. Circuit Amps: 17.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215;
Brand: Coleman Mfg #: TCHD36S43S3

Heat Pump LX Series, 14 SEER, Three-Phase, 4 Ton, R410A B79-365
Heat Pump LX Series, 14 SEER, Three-Phase, 4 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 4; HSPF: 9.00; COP: 3.58; Min. Circuit Amps: 8.66; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 235;
Brand: Coleman Mfg #: THE48B41S

Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A B61-264
Heat Pump LX Series, 14 SEER, Three-Phase, 3 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 3; HSPF: 8.55; COP: 3.48; Min. Circuit Amps: 7.05; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE36B42S

3 Ton Heat Pump 14 SEER 3 Phase 208/230V B79-501
3 Ton Heat Pump 14 SEER 3 Phase 208/230V
SEER: 14; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 32,800; Volts: 208/230; Phase: Three; HSPF: 8.5; COP: 4.46; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 232;
Brand: Daikin Mfg #: DZ14SA0363

4 Ton Heat Pump 14 SEER 3 Phase 208/230V B79-503
4 Ton Heat Pump 14 SEER 3 Phase 208/230V
SEER: 14; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 45,000; BtuH Heating Input: 44,500; Volts: 208/230; Phase: Three; HSPF: 9.0; COP: 4.72; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Width: 29"; Height: 34-1/4"; Depth: 29"; Wt. Lbs.: 235;
Brand: Daikin Mfg #: DZ14SA0483

4 Ton Heat Pump 14 SEER 3 Phase 460V B79-504
4 Ton Heat Pump 14 SEER 3 Phase 460V
EER: 12.5; Nom. Tons: 4; BtuH Cooling: 45,000; BtuH Heating Input: 44,500; Volts: 460; Phase: Three; HSPF: 9.0; COP: 4.72; Min. Circuit Amps: 8.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29"; Height: 34-1/4"; Depth: 29"; Wt. Lbs.: 234;
Brand: Daikin Mfg #: DZ14SA0484

3 TON Heat Pump 14 SEER 3 Phase 460V B79-502
3 TON Heat Pump 14 SEER 3 Phase 460V
SEER: 14; EER: 11.5; Nom. Tons: 3.0; BtuH Cooling: 34,600; BtuH Heating Input: 32,800; Volts: 460; Phase: 3; HSPF: 8.2; COP: 2.4; Min. Circuit Amps: 7.8; Max. Fuse Size: 15; Liquid Conn.: 3/8; Refrigerant: R-410A; Width: 29; Height: 32-1/4; Depth: 29; Wt. Lbs.: 194;
Brand: Daikin Mfg #: DZ14SA0364

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 208/230V B91-947
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 208/230V
SEER: 13; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: 3; Min. Circuit Amps: 21.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240;
Brand: Coleman Mfg #: TCHD48S43S3

Horizontal Discharge Air Conditioning Condenisng Unit 14 SEER, Three-Phase, 3 Ton, R410A, 460V B60-179
Horizontal Discharge Air Conditioning Condenisng Unit 14 SEER, Three-Phase, 3 Ton, R410A, 460V
SEER: 14; EER: 12.20; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 460; Phase: 3; Min. Circuit Amps: 8.0; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215;
Brand: Coleman Mfg #: TCHE36S44S1

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 460V B91-951
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 460V
SEER: 13; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 460; Phase: 3; Min. Circuit Amps: 10.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240;
Brand: Coleman Mfg #: TCHD48S44S3

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 460V B91-950
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 460V
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 460; Phase: 3; Min. Circuit Amps: 8.8; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215;
Brand: Coleman Mfg #: TCHD36S44S3
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare