190 Results

1, 5, 3, 1-1/2, Goodman, Evcon, Daikin, HVAC Equipment

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-963
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt. Lbs.: 188; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXN403610

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-966
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; Nom. Tons: 5; BtuH Cooling: 55,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN406010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-960
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 8.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27"; Depth: 26"; Wt. Lbs.: 118; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN401810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-554
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 3; BtuH Cooling: 35,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 31-1/4"; Height: 33-1/4"; Depth: 35-1/4"; Wt. Lbs.: 185; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC14336B21S

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3 Ton, R410A B66-328
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.5; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB403610

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-685
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH506010

Heat Pump 15.2 SEER2, Single-Phase, 3 Ton, R410A B65-701
Heat Pump 15.2 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 15.2; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 22.8; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH503610

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 1-1/2 Ton, R410A B66-325
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.5; Min. Circuit Amps: 8.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 35-11/16"; Depth:…
Brand: Goodman Mfg #: GSZB401810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-952
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 224; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXB403610

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-956
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.9; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27"; Depth: 26"; Wt. Lbs.: 126; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXM401810

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A B66-331
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB406010

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A B65-723
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A
SEER2: 17.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 24.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 216; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC703610

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-949
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.9; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 144; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB401810

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-704
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 30.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH506010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-551
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 1-1/2; BtuH Cooling: 17,600; Volts: 208/230; Phase: Single; Min. Circuit Amps: 11.8; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-657; OEM TXV for C…
Brand: Evcon Mfg #: RAC14318B21S

Heat Pump 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-698
Heat Pump 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 12.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 29"; Wt. Lbs.:…
Brand: Goodman Mfg #: GSZH501810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-955
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 305; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB406010

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-557
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 30.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC14360B21S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-612
Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.4; Min. Circuit Amps: 19.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC160361

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-296
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 155; OEM TXV: B19-657; OEM TXV…
Brand: Evcon Mfg #: RAC14L36B23S

Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-608
Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 34,800; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 4.65; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC180361

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3 Ton, R410A B65-682
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 15.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXH503610
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare