25 Results

1, 3, Y, Goodman, Daikin, HVAC Equipment

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-952
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 224; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXB403610

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A B65-723
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A
SEER2: 17.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 24.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 216; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC703610

Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-612
Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.4; Min. Circuit Amps: 19.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC160361

Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-608
Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 34,800; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 4.65; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC180361

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3 Ton, R410A B65-682
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 15.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXH503610

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B66-154
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 22.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 458;
Brand: Goodman Mfg #: GPGM33608041

Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A B64-281
Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.28; Min. Circuit Amps: 19.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth:…
Brand: Goodman Mfg #: GSZ140361

Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B66-165
Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 15.2; EER2: 11.2; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 25.8; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 490;
Brand: Goodman Mfg #: GPGM53608041

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B66-153
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 60,000; BtuH Heating Output: 48,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 22.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 453;
Brand: Goodman Mfg #: GPGM33606041

Dual Fuel Packaged Unit 13.4 SEER2, Single-Phase, 3 Ton, R410A, 81% AFUE, 6.7 HSPF2 B66-171
Dual Fuel Packaged Unit 13.4 SEER2, Single-Phase, 3 Ton, R410A, 81% AFUE, 6.7 HSPF2
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; Nom. CFM: 1,050; Min. Circuit Amps: 25.1; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 440;
Brand: Goodman Mfg #: GPDM33608041

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B77-554
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.99; Min. Circuit Amps: 18.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZ160361

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-604
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 36-1/2"; Depth: 35-3/4"; Wt. Lbs.: 201; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC160361

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B73-976
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160361

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B75-682
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 20.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 182; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160371

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-600
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 238; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC180361

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A B64-185
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A
SEER: 20; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 35,400; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 4.14; Min. Circuit Amps: 29.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth:…
Brand: Goodman Mfg #: GVZC200361

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B66-152
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 40,000; BtuH Heating Output: 32,400; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 22.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 449;
Brand: Goodman Mfg #: GPGM33604041

Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A B64-181
Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A
SEER: 20; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 20.6; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 221; OEM TXV: B18-927;
Brand: Goodman Mfg #: GVXC200361

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B75-674
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 62,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 24.4; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 470;
Brand: Goodman Mfg #: GPG1636080M41

Air Conditioning Condensing Unit GSXV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A B66-757
Air Conditioning Condensing Unit GSXV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A
SEER2: 19.2; Nom. Tons: 3; BtuH Cooling: 32,800; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 20.6; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 221; OEM TXV: B18-927;
Brand: Goodman Mfg #: GSXV903610

Heat Pump GSZV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A B66-761
Heat Pump GSZV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A
SEER2: 19.2; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 34,200; Volts: 208/230; Phase: Single; HSPF2: 8.2; COP: 3.6; Min. Circuit Amps: 29.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth: 35-1/2"; Wt. Lbs.:…
Brand: Goodman Mfg #: GSZV903610

Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Multi-Position B77-258
Single Packaged Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 33,600; BtuH Heating Input: 33,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 24.9; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 438;
Brand: Goodman Mfg #: GPH1636M41

Dual Fuel Packaged Unit 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE, 8.0 HSPF B77-165
Dual Fuel Packaged Unit 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE, 8.0 HSPF
SEER: 14; Nom. Tons: 3; BtuH Cooling: 35,200; BtuH Heating Input: 80,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 24.2; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 440;
Brand: Goodman Mfg #: GPD1436080M41

Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 3T, R410A, Horizontal B66-117
Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 3T, R410A, Horizontal
SEER2: 15.2; EER2: 11.4; Nom. Tons: 3; BtuH Cooling: 34,800; BtuH Heating Input: 32,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.74; Nom. CFM: 1,200; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPHH53641
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare