Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-960
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 8.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27"; Depth: 26"; Wt. Lbs.: 118; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN401810

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 1-1/2 Ton, R410A B66-325
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.5; Min. Circuit Amps: 8.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 35-11/16"; Depth:…
Brand: Goodman Mfg #: GSZB401810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-956
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.9; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27"; Depth: 26"; Wt. Lbs.: 126; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXM401810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-949
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.9; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 144; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB401810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-551
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 1-1/2; BtuH Cooling: 17,600; Volts: 208/230; Phase: Single; Min. Circuit Amps: 11.8; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-657; OEM TXV for C…
Brand: Evcon Mfg #: RAC14318B21S

Heat Pump 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-698
Heat Pump 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 12.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 29"; Wt. Lbs.:…
Brand: Goodman Mfg #: GSZH501810

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-679
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 11.9; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27"; Depth: 26"; Wt. Lbs.: 126; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXH501810

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 1-1/2 Ton, R410A B66-580
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 13.4; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 8.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27"; Depth: 26"; Wt. Lbs.: 117; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN3N1810

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 1-1/2 Ton, R410A B98-344
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 8.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 102; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130181

Heat Pump 14 SEER, Single-Phase, 1-1/2 Ton, R410A B75-913
Heat Pump 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.6; Min. Circuit Amps: 8.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140181

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 1-1/2 Ton, R410A B61-288
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 13; EER: 12.75; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 12.9; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 120; OEM TXV: B19-657; OEM TXV…
Brand: Evcon Mfg #: RAC13L18B23S 

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 1-1/2 Ton, R410A B61-450
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 8.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 126; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140181

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 1-1/2 Ton, R410A B73-973
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 12.4; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 145; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160181

Heat Pump LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A B78-398
Heat Pump LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.82; Min. Circuit Amps: 12.0; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height:…
Brand: Evcon Mfg #: RHP14L18B23S

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410a B66-134
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410a
SEER2: 14.3; EER2: 12; Nom. Tons: 1.5; BtuH Cooling: 17,200; BtuH Heating Input: 16,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 7.5; COP: 3.76; Min. Circuit Amps: 9.1; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4";…
Brand: Evcon Mfg #: RHP14318B21S

Heat Pump 14 SEER, Single-Phase, 1-1/2 Ton, R410A B79-084
Heat Pump 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 1-1/2; BtuH Cooling: 17,400; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.26; Min. Circuit Amps: 12.4; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140191

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 1-1/2 Ton, R410A B76-578
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 12.0; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140191

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A B61-293
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 13.25; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 12.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 30"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Evcon Mfg #: RAC14L18B23S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 1-1/2 Ton, R410A B60-819
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 8.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 135; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S181

Heat Pump 16 SEER, Single-Phase, 1-1/2 Ton, R410A B77-551
Heat Pump 16 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.95; Min. Circuit Amps: 12.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 36-3/8";…
Brand: Goodman Mfg #: GSZ160181

Heat Pump LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A B62-881
Heat Pump LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,600; BtuH Heating Input: 16,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.55; COP: 3.50; Min. Circuit Amps: 10.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4";…
Brand: Evcon Mfg #: REP14L18B21S

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 1.5 Ton, R410A B91-670
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 1.5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 9.1; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 102; OEM TXV: B18-099;
Brand: Goodman Mfg #: VSX130181

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 1-1/2 Ton, R410A B66-133
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 8.9; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 30"; Depth: 24"; Wt. Lbs.: 120; OEM TXV: B19-657; OEM TXV for C…
Brand: Evcon Mfg #: RAC13L18B24S

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A B66-281
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 15.2; EER2: 12.5; Nom. Tons: 1-1/2; BtuH Cooling: 17,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 13.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 140; OEM TXV:…
Brand: Evcon Mfg #: RAC15018B21S