184 Results

1, 5, 3-1/2, 2, Goodman, Evcon, HVAC Equipment

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-961
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 138; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-964
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 3-1/2; BtuH Cooling: 39,500; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 226; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN404210

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-966
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; Nom. Tons: 5; BtuH Cooling: 55,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN406010

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 2 Ton, R410A B66-326
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.6; Min. Circuit Amps: 11.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 35-11/16"; Depth: 29";…
Brand: Goodman Mfg #: GSZB402410

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3-1/2 Ton, R410A B66-329
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.6; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-13/16";…
Brand: Goodman Mfg #: GSZB404210

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-957
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXM402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-552
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 2; BtuH Cooling: 23,200; Volts: 208/230; Phase: Single; Min. Circuit Amps: 15.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-657; OEM TXV for C Series…
Brand: Evcon Mfg #: RAC14324B21S

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-685
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH506010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-950
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 169; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-953
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB404210

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A B66-331
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB406010

Heat Pump 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-702
Heat Pump 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2";…
Brand: Goodman Mfg #: GSZH504210

Heat Pump 15.2 SEER2, Single-Phase, 2 Ton, R410A B65-699
Heat Pump 15.2 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH502410

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-704
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 30.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH506010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-555
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-1/4"; Height: 36-1/4"; Depth: 35-1/4"; Wt. Lbs.: 215; OEM TXV: B19-659; OEM TXV for…
Brand: Evcon Mfg #: RAC14342B21S

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-955
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 305; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB406010

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-557
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 30.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC14360B21S

Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-607
Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 5.65; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC180241

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-611
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.96; Min. Circuit Amps: 13.5; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160241

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A B65-680
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXH502410

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-683
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH504210

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B75-914
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.39; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140241