121 Results

1, Y, Goodman, HVAC Equipment

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-685
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH506010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-952
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 224; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXB403610

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-950
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 169; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-953
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB404210

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-951
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2-1/2; BtuH Cooling: 28,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 224; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXB403010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 4 Ton, R410A B65-954
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 14.3; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB404810

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A B65-723
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A
SEER2: 17.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 24.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 216; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC703610

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-949
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.9; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 144; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB401810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-955
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 305; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB406010

Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-612
Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.4; Min. Circuit Amps: 19.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC160361

Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-607
Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 5.65; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC180241

Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-608
Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 34,800; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 4.65; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC180361

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-611
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.96; Min. Circuit Amps: 13.5; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160241

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-609
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 49,500; BtuH Heating Input: 51,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.76; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180481

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-613
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 5.16; Min. Circuit Amps: 26.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160481

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3 Ton, R410A B65-682
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 15.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXH503610

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A B65-680
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXH502410

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 4 Ton, R410A B65-684
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 15.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH504810

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-681
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXH503010

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-683
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH504210

Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A B75-914
Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.39; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 34-1/2"; Depth:…
Brand: Goodman Mfg #: GSZ140241

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 2-1/2 Ton, 81% AFUE, R410A, Multi-Position B66-151
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 2-1/2 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 2-1/2; BtuH Cooling: 28,600; BtuH Heating Input: 60,000; BtuH Heating Output: 48,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,000; Min. Circuit Amps: 22.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 420;
Brand: Goodman Mfg #: GPGM33006041
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare