Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B66-163
Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 15.2; EER2: 11.2; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 60,000; BtuH Heating Output: 48,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 18.4; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 370;
Brand: Goodman Mfg #: GPGM52406041

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal B90-040
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 875; Min. Circuit Amps: 15.0; Max. Fuse Size: 20; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPC1424H41

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A B79-087
Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 33,000; BtuH Heating Input: 34,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.57; Min. Circuit Amps: 18.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZ140371

Single Packaged Heat Pump 14 SEER, Single-Phase, 3 Tons, R410A, Multi-Position B76-803
Single Packaged Heat Pump 14 SEER, Single-Phase, 3 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 34,400; BtuH Heating Input: 33,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,200; Min. Circuit Amps: 26.6; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 400;
Brand: Goodman Mfg #: GPH1436M41

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 5 Ton, 80% AFUE, R410A, Multi-Position B77-559
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 5 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 100,000; BtuH Heating Output: 78,000; Volts: 208/230; Phase: Single; Motor Type: EEM; Min. Circuit Amps: 35.0; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 538;
Brand: Goodman Mfg #: GPG1461100M41

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A B91-676
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B60-820
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 132; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S241

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A B64-185
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A
SEER: 20; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 35,400; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 4.14; Min. Circuit Amps: 29.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth:…
Brand: Goodman Mfg #: GVZC200361

Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, Multi-Position B76-782
Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 26.2; Max. Fuse Size: 40; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 365;
Brand: Goodman Mfg #: GPC1436M41

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 5 Ton, 80% AFUE, R410A, Multi-Position B77-560
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 5 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 120,000; BtuH Heating Output: 94,000; Volts: 208/230; Phase: Single; Motor Type: EEM; Min. Circuit Amps: 35.0; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 543;
Brand: Goodman Mfg #: GPG1461120M41

Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, Horizontal B90-042
Single Packaged Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 3; BtuH Cooling: 35,600; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 1,200; Min. Circuit Amps: 26.7; Max. Fuse Size: 40; Refrigerant: R410A; Width: 66"; Height: 35-1/2"; Depth: 33"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPC1436H41

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B66-152
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 40,000; BtuH Heating Output: 32,400; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 22.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 449;
Brand: Goodman Mfg #: GPGM33604041

Single Packaged Gas/Electric  Air Conditioner 14 SEER, Single-Phase, 3 Ton, 80% AFUE, R410A, Multi-Position B76-792
Single Packaged Gas/Electric Air Conditioner 14 SEER, Single-Phase, 3 Ton, 80% AFUE, R410A, Multi-Position
SEER: 14; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 64,000; Volts: 208/230; Phase: Single; Motor Type: EEM; Min. Circuit Amps: 23.0; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 459;
Brand: Goodman Mfg #: GPG1436080M41

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A B64-187
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A
SEER: 20; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 52,000; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 3.68; Min. Circuit Amps: 30.6; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth:…
Brand: Goodman Mfg #: GVZC200601

Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B77-256
Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 376;
Brand: Goodman Mfg #: GPH1624M41

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B60-822
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX16S361

Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A B64-181
Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 3 Ton, R410A
SEER: 20; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 20.6; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 221; OEM TXV: B18-927;
Brand: Goodman Mfg #: GVXC200361

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A B64-184
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A
SEER: 20; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,800; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 3.7; Min. Circuit Amps: 15.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2";…
Brand: Goodman Mfg #: GVZC200241

Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A B64-180
Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A
SEER: 20; Nom. Tons: 2; BtuH Cooling: 24,200; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 15.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 210; OEM TXV: B18-926;
Brand: Goodman Mfg #: GVXC200241

Single Packaged Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A, Horizontal B90-051
Single Packaged Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A, Horizontal
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 54,500; Volts: 208/230; Phase: Single; Motor Type: EEM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,700; Min. Circuit Amps: 40.0; Refrigerant: R410A; Width: 66"; Height: 38-3/4"; Depth: 34"; Wt. Lbs.: 400;
Brand: Goodman Mfg #: GPH1460H41

Single Packaged Heat Pump GPHH3 Series, 13.4 SEER2, Single-Phase, 3T, R410A, Horizontal B66-004
Single Packaged Heat Pump GPHH3 Series, 13.4 SEER2, Single-Phase, 3T, R410A, Horizontal
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 35,200; BtuH Heating Input: 32,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.7; Nom. CFM: 1,200; Min. Circuit Amps: 26.0; Refrigerant: R410A; Width: 66"; Height: 35"; Depth: 34"; Wt. Lbs.: 375;
Brand: Goodman Mfg #: GPHH33641

Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, Multi-Position B76-785
Single Packaged Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,700; Min. Circuit Amps: 40.3; Max. Fuse Size: 60; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 458;
Brand: Goodman Mfg #: GPC1460M41

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B76-780
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 14.6; Max. Fuse Size: 20; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 319;
Brand: Goodman Mfg #: GPC1424M41