Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-962
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2-1/2; BtuH Cooling: 28,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 156; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXN403010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-964
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 3-1/2; BtuH Cooling: 39,500; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 226; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN404210

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 4 Ton, R410A B65-965
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 13.8; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 226; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN404810

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-966
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; Nom. Tons: 5; BtuH Cooling: 55,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN406010

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 2-1/2 Ton, R410A B66-327
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 2-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.9; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 39-8/16"; Depth:…
Brand: Goodman Mfg #: GSZB403010

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3-1/2 Ton, R410A B66-329
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.6; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-13/16";…
Brand: Goodman Mfg #: GSZB404210

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-685
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH506010

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 4 Ton, R410A B66-330
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 4 Ton, R410A
SEER2: 14.3; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-7/16"; Depth:…
Brand: Goodman Mfg #: GSZB404810

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-958
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXM403010

Heat Pump 15.2 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-700
Heat Pump 15.2 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2";…
Brand: Goodman Mfg #: GSZH503010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-953
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 3-1/2; BtuH Cooling: 40,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB404210

Heat Pump 15.2 SEER2, Single-Phase, 4 Ton, R410A B65-703
Heat Pump 15.2 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 15.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH504810

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A B66-331
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB406010

Heat Pump 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A B65-702
Heat Pump 15.2 SEER2, Single-Phase, 3-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 23.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2";…
Brand: Goodman Mfg #: GSZH504210

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-951
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2-1/2; BtuH Cooling: 28,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 224; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXB403010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 4 Ton, R410A B65-954
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 14.3; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB404810

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-704
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 30.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH506010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-955
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 305; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB406010

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-609
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 49,500; BtuH Heating Input: 51,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.76; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180481

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-613
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 5.16; Min. Circuit Amps: 26.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160481

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 4 Ton, R410A B65-684
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 15.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH504810

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-681
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXH503010