53 Results

1, 2, Goodman, HVAC Equipment

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-579
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140251

Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B66-163
Single Packaged Gas/Electric Air Conditioner 15.2 SEER2, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 15.2; EER2: 11.2; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 60,000; BtuH Heating Output: 48,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 18.4; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 370;
Brand: Goodman Mfg #: GPGM52406041

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal B90-040
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 875; Min. Circuit Amps: 15.0; Max. Fuse Size: 20; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPC1424H41

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B60-820
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 132; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S241

Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B77-256
Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 376;
Brand: Goodman Mfg #: GPH1624M41

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A B64-184
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A
SEER: 20; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,800; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 3.7; Min. Circuit Amps: 15.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2";…
Brand: Goodman Mfg #: GVZC200241

Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A B64-180
Air Conditioning Condensing Unit 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A
SEER: 20; Nom. Tons: 2; BtuH Cooling: 24,200; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 15.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 210; OEM TXV: B18-926;
Brand: Goodman Mfg #: GVXC200241

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position B76-780
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 14.6; Max. Fuse Size: 20; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 319;
Brand: Goodman Mfg #: GPC1424M41

Single Packaged Heat Pump GPHH3 Series, 13.4 SEER2, Single-Phase, 2T, R410A, Horizontal B66-002
Single Packaged Heat Pump GPHH3 Series, 13.4 SEER2, Single-Phase, 2T, R410A, Horizontal
SEER2: 13.4; EER2: 10.6; Nom. Tons: 2; BtuH Cooling: 23,400; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.6; Nom. CFM: 875; Min. Circuit Amps: 20.8; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPHH32441

Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal B90-046
Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: EEM; HSPF: 8.0; COP: 3.8; Nom. CFM: 800; Min. Circuit Amps: 21.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1424H41

Heat Pump GSZM4 Series, 14.3 SEER2, 7.5HSPF2, 2 Ton, R410A B66-333
Heat Pump GSZM4 Series, 14.3 SEER2, 7.5HSPF2, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.6; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 35-11/16"; Depth: 29";…
Brand: Goodman Mfg #: GSZM402410

Single Packaged Air Conditioner GPCH3 Series, 13.4 SEER2, Single-Phase, 2T, R410A, Horizontal B65-995
Single Packaged Air Conditioner GPCH3 Series, 13.4 SEER2, Single-Phase, 2T, R410A, Horizontal
SEER2: 13.4; EER2: 10.6; Nom. Tons: 2; BtuH Cooling: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 875; Min. Circuit Amps: 14.4; Max. Fuse Size: 20; Refrigerant: R410A; Width: 66"; Height: 22"; Depth: 34'; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPCH32441

Single Packaged Air Conditioner GPCM3 Series, 13.4 SEER2, 2 Ton, R410A, Multi-Position B66-336
Single Packaged Air Conditioner GPCM3 Series, 13.4 SEER2, 2 Ton, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 2; BtuH Cooling: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 21,6; Max. Fuse Size: 35; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 319;
Brand: Goodman Mfg #: GPCM32441

Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Horizontal B76-931
Single Packaged Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 16; EER: 13; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.8; Nom. CFM: 875; Min. Circuit Amps: 21.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1624H41

Air Conditioning Condensing Unit GSXV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A B66-756
Air Conditioning Condensing Unit GSXV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A
SEER2: 19.2; Nom. Tons: 2; BtuH Cooling: 22,600; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; Min. Circuit Amps: 15.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 210; OEM TXV: B18-926;
Brand: Goodman Mfg #: GSXV902410

Heat Pump GSZV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A B66-760
Heat Pump GSZV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 2 Ton, R410A
SEER2: 19.2; Nom. Tons: 2; BtuH Cooling: 23,200; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; HSPF2: 8.2; COP: 3.53; Min. Circuit Amps: 15.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.:…
Brand: Goodman Mfg #: GSZV902410

Dual Fuel Packaged Unit 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, 8.0 HSPF B77-163
Dual Fuel Packaged Unit 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE, 8.0 HSPF
SEER: 14; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 60,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 21.2; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 420;
Brand: Goodman Mfg #: GPD1424060M41

Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position B75-672
Single Packaged Gas/Electric Air Conditioner 16 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Multi-Position
SEER: 16; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 22,800; BtuH Heating Input: 60,000; BtuH Heating Output: 47,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 800; Min. Circuit Amps: 19.5; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 370;
Brand: Goodman Mfg #: GPG1624060M41

Single Packaged Heat Pump GPHM5 Series, 15.2 SEER2, Single-Phase, 2 Ton, R410A, Multi-Position B66-348
Single Packaged Heat Pump GPHM5 Series, 15.2 SEER2, Single-Phase, 2 Ton, R410A, Multi-Position
SEER2: 15.2; EER2: 11.4; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.68; Nom. CFM: 850; Min. Circuit Amps: 18.7; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 376;
Brand: Goodman Mfg #: GPHM52441

Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx B64-920
Gas/Electric Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, 81% AFUE, R410A, Ultra LowNOx
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,000; BtuH Heating Input: 40,000; BtuH Heating Output: 31,000; Volts: 208/230; Phase: Single; Nom. CFM: 800; Min. Circuit Amps: 14.4; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 412;
Brand: Goodman Mfg #: GPU1424040M41

Single Packaged Air Conditioner 15 SEER, Single-Phase, 2 Ton, R410A, Horizontal B77-197
Single Packaged Air Conditioner 15 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 15; EER: 12; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 875; Min. Circuit Amps: 15.0; Max. Fuse Size: 20; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 300;
Brand: Goodman Mfg #: GPC1524H41

Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 2T, R410A, Horizontal B66-115
Single Packaged Heat Pump GPHH5 Series, 15.2 SEER2, Single-Phase, 2T, R410A, Horizontal
SEER2: 15.2; EER2: 11.4; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.73; Nom. CFM: 875; Min. Circuit Amps: 21.3; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPHH52441

Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-224
Heat Pump 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.74; Min. Circuit Amps: 15.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth:…
Brand: Goodman Mfg #: DSZC160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B91-217
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 181; OEM TXV: B18-099;
Brand: Goodman Mfg #: DSXC160241