Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-966
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; Nom. Tons: 5; BtuH Cooling: 55,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN406010

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-538
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 30.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-3/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for C…
Brand: Coleman Mfg #: TCE2B60S21S

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-685
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH506010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-955
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 305; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB406010

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-557
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 30.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC14360B21S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A B60-668
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659;…
Brand: Coleman Mfg #: AC19B6021S

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-688
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2"; Depth: 38-1/4"; Wt. Lbs.: 270;
Brand: Coleman Mfg #: AC21B6021S

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B98-350
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130601

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B62-070
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 29.1; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 190; OEM TXV: B19-660;…
Brand: Coleman Mfg #: TC3B6022S

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 5 Ton, R410A B65-725
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 5 Ton, R410A
SEER2: 17.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC706010

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A B66-586
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.4; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 227; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN3N6010

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B77-529
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-660; OEM…
Brand: Evcon Mfg #: RAC13L60B23S

Horizontal Discharge Air Conditioning Condensing Unit 18.5 SEER2, Single-Phase, Modulating, 5 Ton, R410A B66-302
Horizontal Discharge Air Conditioning Condensing Unit 18.5 SEER2, Single-Phase, Modulating, 5 Ton, R410A
SEER2: 18.5; EER2: 10.0; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 35.0; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 37-3/8"; Height: 54-5/8"; Depth: 13-3/8"; Wt. Lbs.: 207; OEM TXV: B19-659; OEM TXV for X…
Brand: Coleman Mfg #: HMCG22B601S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 5 Ton, R410A B78-423
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 5 Ton, R410A
SEER: 17; EER: 12; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4"; Depth: 34-1/4"; Wt. Lbs.: 265; OEM TXV: B20-463; OEM TXV…
Brand: Coleman Mfg #: CC7B6021S

Air Conditioning Condensing Unit LX Series, 15.2 SEER2, Single-Phase, 5 Ton, R410A B66-280
Air Conditioning Condensing Unit LX Series, 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; EER2: 12.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.0; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 255; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TCF2B60T21S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only B77-431
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TC4B6021S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A B75-912
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-602
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 326; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180601

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B77-536
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 220; OEM TXV: B19-660; OEM TXV for…
Brand: Evcon Mfg #: RAC14L60B23S

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A B91-676
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130601

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southwest Region Only B77-438
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 205; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TW4B6021S

Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 5 Ton, R410A B91-944
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 250; OEM TXV: B19-660; OEM TXV for…
Brand: Coleman Mfg #: TCHD60S41S3
FTL Finance