16 Results

5, 4, 11 to 11.9, Goodman, Split Systems, Residential Unitary, HVAC Equipment

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A B98-349
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 175; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130481

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B98-350
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130601

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B75-918
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.72; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: GSZ140481

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B75-919
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140601

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A B75-911
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140481

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A B75-912
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140601

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 4 Ton, R410A B91-675
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 175; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130481

Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A B91-676
Air Conditioning Condensing Unit GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX130601

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B75-677
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 26; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140491

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B73-806
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 211; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130611

Heat Pump GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A B75-932
Heat Pump GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9; COP: 4.72; Min. Circuit Amps: 24.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: VSZ140481

Heat Pump GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A B75-933
Heat Pump GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: VSZ140601

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A B75-926
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX140601

Heat Pump GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A B75-679
Heat Pump GMC Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: VSZ140491

Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A B75-925
Air Conditioning Condensing Unit GMC Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Goodman Mfg #: VSX140481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B74-721
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 57,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 291; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160611
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare