Heat Pump 18 SEER, Single-Phase, 3 Ton, R410A B64-392
Heat Pump 18 SEER, Single-Phase, 3 Ton, R410A
SEER: 18; EER: 10.4; Nom. Tons: 1-1/2–3; BtuH Cooling: 33,600; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; Min. Circuit Amps: 24.8; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/8"; Height: 24-5/16"; Depth:…
Brand: Bosch Mfg #: BOVB-36HDN1-M18M

Heat Pump 20 SEER, Single-Phase, 3 Ton, R410A B62-566
Heat Pump 20 SEER, Single-Phase, 3 Ton, R410A
SEER: 20; EER: 12.5; Nom. Tons: 1-1/2–3; BtuH Cooling: 34,600; BtuH Heating Input: 34,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; Min. Circuit Amps: 26.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/8"; Height: 24-5/16"; Depth:…
Brand: Bosch Mfg #: BOVA-36HDN1-M20G

Heat Pump 18 SEER, Single-Phase, 5 Ton, R410A B64-393
Heat Pump 18 SEER, Single-Phase, 5 Ton, R410A
SEER: 18; EER: 10.2; Nom. Tons: 3-1/2–5; BtuH Cooling: 55,000; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; Min. Circuit Amps: 38.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/8"; Height: 33-3/16"; Depth:…
Brand: Bosch Mfg #: BOVB-60HDN1-M18M

Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A B62-567
Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 12.5; Nom. Tons: 3-1/2–5; BtuH Cooling: 54,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; Min. Circuit Amps: 38.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/8"; Height: 33-3/16"; Depth:…
Brand: Bosch Mfg #: BOVA-60HDN1-M20G

Heat Pump 15 SEER, Single-Phase, 3 Ton, R410A B65-705
Heat Pump 15 SEER, Single-Phase, 3 Ton, R410A
SEER: 15; EER: 10.4; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; HSPF: 9.0; Min. Circuit Amps: 26.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 28"; Height: 24-15/16"; Depth: 28"; Wt. Lbs.: 134;
Brand: Bosch Mfg #: BOVA36HDN1M15G

Heat Pump 15 SEER, Single-Phase, 5 Ton, R410A B65-706
Heat Pump 15 SEER, Single-Phase, 5 Ton, R410A
SEER: 15; EER: 10.0; Nom. Tons: 5; BtuH Cooling: 50,000; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; HSPF: 9.0; Min. Circuit Amps: 39.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/8"; Height: 33-3/16"; Depth: 29-1/8"; Wt. Lbs.: 186;
Brand: Bosch Mfg #: BOVA60HDN1M15G

Heat Pump 15 SEER, Single-Phase, 2 Ton, R410A B65-707
Heat Pump 15 SEER, Single-Phase, 2 Ton, R410A
SEER: 15; EER: 11.2; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; HSPF: 9.0; Min. Circuit Amps: 22.9; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 28"; Height: 24-15/16"; Depth: 28"; Wt. Lbs.: 126;
Brand: Bosch Mfg #: BOVA24HDN1M15G

Heat Pump 20 SEER, Single-Phase, 3 Ton, R410A, Connected B66-242
Heat Pump 20 SEER, Single-Phase, 3 Ton, R410A, Connected
SEER: 20; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 34,600; BtuH Heating Input: 34,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; Min. Circuit Amps: 26.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/8"; Height: 24.938"; Depth: 29…
Brand: Bosch Mfg #: BOVB-36HDN1-M20G

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-149
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 3; BtuH Cooling: 34,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.72; Min. Circuit Amps: 21.99; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3622S

Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A, Connected B66-243
Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A, Connected
SEER: 19; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; Min. Circuit Amps: 38.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 33-1/5"; Height: 33-1/5"; Depth: 29…
Brand: Bosch Mfg #: BOVB-60HDN1-M20G

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B61-218
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3621S

Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A B61-217
Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.22; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3021S

Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A B61-216
Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.22; Min. Circuit Amps: 15.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B2421S

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B61-220
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.04; Min. Circuit Amps: 25.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B4821S

Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A B61-219
Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 28.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B4221S

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Heat Pump 20 SEER, Single-Phase, Modulating, 3 Ton, R410A B79-690
Heat Pump 20 SEER, Single-Phase, Modulating, 3 Ton, R410A
SEER: 20; EER: 14.15; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 11.0; COP: 3.0; Min. Circuit Amps: 25.7; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 32"; Height: 40-1/4"; Depth:…
Brand: Coleman Mfg #: HC20B3621S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 3 Ton, R410A B60-670
Heat Pump 19 SEER, Single-Phase, Two-Stage, 3 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 4.2; Min. Circuit Amps: 21.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B3621S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 2 Ton, R410A B60-669
Heat Pump 19 SEER, Single-Phase, Two-Stage, 2 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.08; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 31-3/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: HC19B2421S

Heat Pump 16 SEER, Single-Phase, 1-1/2 Ton, R410A B61-215
Heat Pump 16 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 14.0; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: CH6B1821S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 4 Ton, R410A B60-671
Heat Pump 19 SEER, Single-Phase, Two-Stage, 4 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 4.1; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B4821S

Heat Pump 20 SEER, Single-Phase, Modulating, 2 Ton, R410A B79-689
Heat Pump 20 SEER, Single-Phase, Modulating, 2 Ton, R410A
SEER: 20; EER: 13.5; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 11.0; COP: 3.86; Min. Circuit Amps: 17.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 32"; Height: 40-1/4"; Depth:…
Brand: Coleman Mfg #: HC20B2421S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A B60-672
Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 3.86; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B6021S

Heat Pump 20 SEER, Single-Phase, Modulating, 4 Ton, R410A B79-691
Heat Pump 20 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 20; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.26; Min. Circuit Amps: 28.6; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC20B4821S