39 Results

5, Heat Pumps, Split Systems, Residential Unitary, HVAC Equipment

Heat Pump 15 SEER, Single-Phase, 5 Ton, R410A B65-706
Heat Pump 15 SEER, Single-Phase, 5 Ton, R410A
SEER: 15; EER: 10.0; Nom. Tons: 5; BtuH Cooling: 50,000; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; HSPF: 9.0; Min. Circuit Amps: 39.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/8"; Height: 33-3/16"; Depth: 29-1/8"; Wt. Lbs.: 186;
Brand: Bosch Mfg #: BOVA60HDN1M15G

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A B66-331
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB406010

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-704
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 30.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH506010

Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A, Connected B66-243
Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A, Connected
SEER: 19; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; Min. Circuit Amps: 38.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 33-1/5"; Height: 33-1/5"; Depth: 29…
Brand: Bosch Mfg #: BOVB-60HDN1-M20G

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A B60-672
Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 3.86; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B6021S

Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-692
Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.78; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height:…
Brand: Coleman Mfg #: HC20B6021S

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B75-919
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140601

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-748
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,000; BtuH Heating Input: 54,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; HSPF2: 8.2; COP: 3.6; Min. Circuit Amps: 30.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 46";…
Brand: Coleman Mfg #: THE2B60T21S

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 5 Ton, R410A B64-416
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 17; EER: 8.5; Nom. Tons: 5; BtuH Cooling: 58,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 3.24; Min. Circuit Amps: 37; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 37-3/8"; Height: 54-5/8"; Depth:…
Brand: Coleman Mfg #: HMH72B601S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-662
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 55,500; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.88; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4"; Depth:…
Brand: Coleman Mfg #: TH4B6022S

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B62-868
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.70; Min. Circuit Amps: 29.1; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4";…
Brand: Coleman Mfg #: TE4B6021S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-664
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.92; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-1/2";…
Brand: Evcon Mfg #: RHP14L60B23S

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B66-565
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 282; OEM…
Brand: Coleman Mfg #: THF2B60T21S

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410a B66-140
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410a
SEER2: 14.3; EER2: 11; Nom. Tons: 5; BtuH Cooling: 55,000; BtuH Heating Input: 54,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 7.5; COP: 3.6; Min. Circuit Amps: 30.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 46"; Depth:…
Brand: Evcon Mfg #: RHP14360B21S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B62-887
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.70; Min. Circuit Amps: 29.1; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4";…
Brand: Evcon Mfg #: REP14L60B21S

Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A B64-187
Heat Pump 20 SEER, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A
SEER: 20; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 52,000; Volts: 208/230; Phase: Single; Motor Type: Variable-Speed; COP: 3.68; Min. Circuit Amps: 30.6; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth:…
Brand: Goodman Mfg #: GVZC200601

Inverter Drive Side Discharge Heat Pump 16.2 SEER2, Single-Phase, 5 Ton, Variable-Speed B66-628
Inverter Drive Side Discharge Heat Pump 16.2 SEER2, Single-Phase, 5 Ton, Variable-Speed
SEER2: 16.2; Nom. Tons: 5; BtuH Cooling: 53,000; BtuH Heating Input: 54,500; Volts: 208/230; Phase: Single; HSPF2: 8.5; COP: 2.9; Min. Circuit Amps: 36.2; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 36-5/8"; Height: 27-3/8"; Depth: 13-3/4"; Wt. Lbs.: 179;
Brand: Amana Mfg #: ASZS606010

Heat Pump ASZN4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A B66-360
Heat Pump ASZN4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A
SEER2: 14.3; EER2: 7.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Amana Mfg #: ASZN406010

Heat Pump 15.2 SEER, Single-Phase, 5 Ton, R410A B65-714
Heat Pump 15.2 SEER, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; HSPF2: 7.8; COP: 3.7; Min. Circuit Amps: 30.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.:…
Brand: Amana Mfg #: ASZH506010

Heat Pump GSZV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A B66-763
Heat Pump GSZV9 Series, 19.2 SEER2, Variable-Speed, Inverter Drive, Single-Phase, 5 Ton, R410A
SEER2: 19.2; Nom. Tons: 5; BtuH Cooling: 52,500; BtuH Heating Input: 52,500; Volts: 208/230; Phase: Single; HSPF2: 8.2; COP: 3.5; Min. Circuit Amps: 30.6; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4"; Depth: 35-1/2"; Wt. Lbs.:…
Brand: Goodman Mfg #: GSZV906010
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare