294 Results

1, 5, 4, 3, Split Systems, Residential Unitary, HVAC Equipment

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B77-554
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.99; Min. Circuit Amps: 18.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZ160361

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-150
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.76; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: RHP14L36B23S

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-604
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 36-1/2"; Depth: 35-3/4"; Wt. Lbs.: 201; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC160361

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A B75-912
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140601

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B73-976
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160361

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-556
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.75; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160481

Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A B66-466
Air Conditioning Condensing Unit RAC134 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 13.4; EER2: 11.25; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-659; OEM…
Brand: Evcon Mfg #: RAC13436B21S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B62-868
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.70; Min. Circuit Amps: 29.1; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4";…
Brand: Coleman Mfg #: TE4B6021S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B75-682
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 20.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 182; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160371

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-663
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.62; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: RHP14L48B23S

Horizontal Discharge Air Conditioning Condensing Unit 17 SEER2, Single-Phase, Modulating, 3 Ton, R410A B66-300
Horizontal Discharge Air Conditioning Condensing Unit 17 SEER2, Single-Phase, Modulating, 3 Ton, R410A
SEER2: 17.0; EER2: 10.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 23.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 5/8"; Refrigerant: R410A; Width: 35-3/8"; Height: 29-1/2"; Depth: 13-3/8"; Wt. Lbs.: 117; OEM TXV: B19-657; OEM TXV for X…
Brand: Coleman Mfg #: HMCG22B361S

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-600
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 238; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC180361

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3 Ton, R410A B76-581
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX140371

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-664
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.92; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-1/2";…
Brand: Evcon Mfg #: RHP14L60B23S

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B78-401
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.9; COP: 3.76; Min. Circuit Amps: 20.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Evcon Mfg #: RHP14L35B23S

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B66-565
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 282; OEM…
Brand: Coleman Mfg #: THF2B60T21S

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410a B66-140
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410a
SEER2: 14.3; EER2: 11; Nom. Tons: 5; BtuH Cooling: 55,000; BtuH Heating Input: 54,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 7.5; COP: 3.6; Min. Circuit Amps: 30.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 46"; Depth:…
Brand: Evcon Mfg #: RHP14360B21S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B77-535
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 35-1/4"; Wt. Lbs.: 215; OEM TXV: B19-659; OEM…
Brand: Evcon Mfg #: RAC14L48B23S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B73-978
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX160481

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-602
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 326; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180601

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B62-867
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 45,500; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.58; Min. Circuit Amps: 24.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Coleman Mfg #: TE4B4821S

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-601
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 298; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180481
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare