29 Results

16, 5, 4, Split Systems, Residential Unitary, HVAC Equipment

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B61-220
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.04; Min. Circuit Amps: 25.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B4821S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-613
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 5.16; Min. Circuit Amps: 26.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160481

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-556
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.75; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B73-978
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX160481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-605
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 263; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B60-824
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.7; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX16S481

Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 5 Ton, R410A B78-409
Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 16; EER: 10; Nom. Tons: 5; BtuH Cooling: 56,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.22; Min. Circuit Amps: 34.7; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH16B6021S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A B91-188
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.7; COP: 4.54; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4";…
Brand: Amana Mfg #: ASZC160481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B73-985
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 241; OEM TXV: B18-726;
Brand: Amana Mfg #: ASX160481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-986
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301; OEM TXV: B18-727;
Brand: Amana Mfg #: ASX160601

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A B91-181
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC160481

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-549
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.5; COP: 4.75; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Amana Mfg #: ASZ160481

Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 4 Ton, R410A B78-408
Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 16; EER: 10; Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.28; Min. Circuit Amps: 35.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH16B4821S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Ton, R410A B91-189
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.1; COP: 4.45; Min. Circuit Amps: 37.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4";…
Brand: Amana Mfg #: ASZC160601

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Ton, R410A B91-182
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 37.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 296; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC160601

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-550
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.5; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Amana Mfg #: ASZ160601

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B91-227
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.35; COP: 4.45; Min. Circuit Amps: 37.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: DSZC160601

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B91-226
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.75; COP: 4.54; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: DSZC160481

Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 4 Ton, R410A B73-602
Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34"; Height: 40"; Depth: 42-1/4"; Wt. Lbs.: 250; OEM TXV: B18-133;
Brand: Coleman Mfg #: AC6B048F4C