Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 4 Ton, R410A B73-602
Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34"; Height: 40"; Depth: 42-1/4"; Wt. Lbs.: 250; OEM TXV: B18-133;
Brand: Coleman Mfg #: AC6B048F4C

Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 5 Ton, R410A B71-663
Air Conditioning Condensing Unit Echelon™, 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34"; Height: 40"; Depth: 42-1/4"; Wt. Lbs.: 235; OEM TXV: B17-087;
Brand: Coleman Mfg #: AC6B060F3C

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A B60-667
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A
SEER: 19; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: AC19B4821S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A B60-668
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659;…
Brand: Coleman Mfg #: AC19B6021S

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A B79-687
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 20; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.6; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 43-1/4"; Depth: 38-1/4"; Wt. Lbs.: 264;
Brand: Coleman Mfg #: AC21B4821S

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-688
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2"; Depth: 38-1/4"; Wt. Lbs.: 270;
Brand: Coleman Mfg #: AC21B6021S

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A B74-878
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 225; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX130481

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B74-879
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 57,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 209; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX130601

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B74-880
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.5; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 231; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX130611

Air Conditioning Condensing Unit Up to  15 SEER, Single-Phase, 4 Ton, R410A B76-764
Air Conditioning Condensing Unit Up to 15 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX140481

Air Conditioning Condensing Unit Up to  15 SEER, Single-Phase, 5 Ton, R410A B76-765
Air Conditioning Condensing Unit Up to 15 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 192; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX140601

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B76-778
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.72; Min. Circuit Amps: 24.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Amana Mfg #: ANZ140481

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B78-388
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.39; Min. Circuit Amps: 26.0; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Amana Mfg #: ANZ140491

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B76-779
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Amana Mfg #: ANZ140601

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A B99-216
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 46,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 217; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX130481

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B73-809
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 171; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX130611

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A B76-753
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX140481

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A B76-754
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX140601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B73-985
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 241; OEM TXV: B18-726;
Brand: Amana Mfg #: ASX160481

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-986
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301; OEM TXV: B18-727;
Brand: Amana Mfg #: ASX160601

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A B91-181
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 282; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC160481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Ton, R410A B91-182
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 37.2; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 296; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC160601

Air Conditioning Condensing Unit 18 SEER, Single-Phase, 4 Ton, R410A B60-196
Air Conditioning Condensing Unit 18 SEER, Single-Phase, 4 Ton, R410A
SEER: 18; EER: 13.25; Nom. Tons: 4; BtuH Cooling: 47,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 276; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC180481

Air Conditioning Condensing Unit 18 SEER, Single-Phase, 5 Ton, R410A B60-197
Air Conditioning Condensing Unit 18 SEER, Single-Phase, 5 Ton, R410A
SEER: 18; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.0; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC180601
FTL Finance