26 Results

5, 4, 2 to 5, 1-1/2 to 3, 13 to 13.2, Residential Unitary, HVAC Equipment

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B61-220
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.04; Min. Circuit Amps: 25.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B4821S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A B60-667
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A
SEER: 19; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: AC19B4821S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A B60-668
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659;…
Brand: Coleman Mfg #: AC19B6021S

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-609
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 49,500; BtuH Heating Input: 51,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.76; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180481

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A B79-687
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 20; EER: 13; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.6; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 43-1/4"; Depth: 38-1/4"; Wt. Lbs.: 264;
Brand: Coleman Mfg #: AC21B4821S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-613
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 5.16; Min. Circuit Amps: 26.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC160481

Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A B60-672
Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 3.86; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B6021S

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-556
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.75; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160481

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-602
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 326; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180601

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-601
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 18; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.3; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 298; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC180481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B61-605
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 37"; Depth: 35-3/4"; Wt. Lbs.: 263; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160481

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-606
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B60-824
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.7; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX16S481

Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Single-Phase, 4 Ton, R410A B64-769
Single Packaged Air Conditioner Up To 17.1 SEER/13 EER, Single-Phase, 4 Ton, R410A
SEER: 17; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: Direct Drive; Nom. CFM: 1,500; Min. Circuit Amps: 34.3; Refrigerant: R410A; Width: 74"; Height: 39-7/8"; Depth: 48-5/16"; Wt. Lbs.: 590;
Brand: Daikin Mfg #: DRC0481D000001S

Air Conditioning Condensing Unit 20 SEER, Inverter Drive, Variable-Speed, 4 Ton, R410A B77-237
Air Conditioning Condensing Unit 20 SEER, Inverter Drive, Variable-Speed, 4 Ton, R410A
SEER: 20; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 30.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-3/4"; Depth: 35-1/2"; Wt. Lbs.: 268; OEM TXV: B18-928;
Brand: Amana Mfg #: AVXC200481

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A B91-188
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.7; COP: 4.54; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4";…
Brand: Amana Mfg #: ASZC160481

Air Conditioning Condensing Unit 20 SEER, Inverter Drive, Variable-Speed, 5 Ton, R410A B77-238
Air Conditioning Condensing Unit 20 SEER, Inverter Drive, Variable-Speed, 5 Ton, R410A
SEER: 20; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 53,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-3/4"; Depth: 35-1/2"; Wt. Lbs.: 31; OEM TXV: B18-929;
Brand: Amana Mfg #: AVXC200601

Air Conditioning Condensing Unit 18 SEER, Single-Phase, 4 Ton, R410A B60-196
Air Conditioning Condensing Unit 18 SEER, Single-Phase, 4 Ton, R410A
SEER: 18; EER: 13.25; Nom. Tons: 4; BtuH Cooling: 47,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 276; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC180481

Heat Pump 20 SEER, Variable-Speed, 4 Ton, R410A B78-379
Heat Pump 20 SEER, Variable-Speed, 4 Ton, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 4.52; Min. Circuit Amps: 29.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4";…
Brand: Amana Mfg #: AVZC200481

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-549
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.5; COP: 4.75; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Amana Mfg #: ASZ160481

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 4 Ton, R410A B60-970
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 4 Ton, R410A
SEER: 17; EER: 13.25; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: CC17B4821S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A B91-226
Heat Pump 16 SEER, Two-Stage, Single-Phase, 4 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.75; COP: 4.54; Min. Circuit Amps: 27.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height:…
Brand: Goodman Mfg #: DSZC160481

Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Ton, R410A B91-191
Heat Pump 18 SEER, Two-Stage, Single-Phase, 4 Ton, R410A
SEER: 18; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 47,000; BtuH Heating Input: 47,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.5; COP: 4.8; Min. Circuit Amps: 29.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4";…
Brand: Amana Mfg #: ASZC180481
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.