Category Brand EER Enclosure HP Mounting NEMA Frame
Nom. Tons Phase
RPM SEER Volts Country of Origin
348 Results

OEM Replacement Draft Inducer Blowers, Blowers & Draft Inducers, Motors, Through the Wall Condensing Units & Heat Pumps, Specialty, HVAC Equipment

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2 Ton, R410A B61-446
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2 Ton, R410A
Nom. Tons: 2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24"; Height: 32"; Depth: 19"; Wt. Lbs.: 175;
Brand: First Co Mfg #: 24WCX12-AB

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2 Ton, R410A B61-447
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2 Ton, R410A
Nom. Tons: 2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26"; Height: 28"; Depth: 19"; Wt. Lbs.: 175;
Brand: First Co Mfg #: 24WCX12-BB

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A B61-448
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24"; Height: 32"; Depth: 19"; Wt. Lbs.: 180;
Brand: First Co Mfg #: 30WCXA12-AB

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 1-1/2 Ton, R410A B61-444
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 1-1/2 Ton, R410A
Nom. Tons: 1-1/2; SEER: 12; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24"; Height: 32"; Depth: 19"; Wt. Lbs.: 170;
Brand: First Co Mfg #: 18WCX12-AB

Replacement for Lennox Draft Inducer Blower X82-117
Replacement for Lennox Draft Inducer Blower
HP: 1/15; Volts: 115; RPM: 3400; Speeds: 1; F/L Amps: 2.35; Rot.: CCW; Bearing Type: Ball; Safety Switch: No; Replaces: 7021-11634; Wt. Lbs.: 7.10;
Brand: Fasco Mfg #: A211

Replacement for Trane Draft Inducer Blowers X82-148
Replacement for Trane Draft Inducer Blowers
HP: 1/12; Volts: 208-230; RPM: 3500; F/L Amps: 0.65; Rot.: CW; Bearing Type: Ball; Safety Switch: No; Replaces: 7062-3971; Wt. Lbs.: 6.00;
Brand: Fasco Mfg #: A272

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A B61-449
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26"; Height: 28"; Depth: 19"; Wt. Lbs.: 180;
Brand: First Co Mfg #: 30WCXA12-BB

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 1-1/2 Ton, R410A B61-445
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 1-1/2 Ton, R410A
Nom. Tons: 1-1/2; SEER: 12; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26"; Height: 28"; Depth: 19"; Wt. Lbs.: 165;
Brand: First Co Mfg #: 18WCX12-BB

Replacement for Rheem Draft Inducer Blower X89-593
Replacement for Rheem Draft Inducer Blower
HP: 1/30; Volts: 120; RPM: 3000; Speeds: 1; F/L Amps: 1.71; Rot.: CCWLE; Bearing Type: Ball; Safety Switch: No; Replaces: Rheem 70-22838-02, 70-24157-03 and 117847-07; Wt. Lbs.: 6.75;
Brand: Packard Mfg #: 66847

Replacement for Rheem Inducer Blower X89-570
Replacement for Rheem Inducer Blower
HP: 1/20; Volts: 115; RPM: 3450; F/L Amps: 0.75; Rot.: CWSE; Bearing Type: Slv; Safety Switch: No; Replaces: 7062-3861; Wt. Lbs.: 5.00;
Brand: Fasco Mfg #: A136

Replacement for Trane Draft Inducer Blowers X89-577
Replacement for Trane Draft Inducer Blowers
HP: 1/50; Volts: 115; RPM: 3000; F/L Amps: 0.95; Rot.: CWSE; Bearing Type: Slv; Safety Switch: No; Replaces: 7021-8428, 7021-8013, 7021-8924, 7021-9639, 7021-9055; Wt. Lbs.: 4.50;
Brand: Fasco Mfg #: A143

Replacement for Rheem Draft Inducer Blower X89-992
Replacement for Rheem Draft Inducer Blower
HP: 1/50; Volts: 208/230; RPM: 3200; F/L Amps: 0.62; Rot.: CW; Bearing Type: Slv; Safety Switch: No; Replaces: 70-23641-81; Wt. Lbs.: 5.80;
Brand: Fasco Mfg #: A241

Replacement for Lennox Draft Inducer Blower X89-984
Replacement for Lennox Draft Inducer Blower
HP: 1/30; Volts: 115; RPM: 3000; Speeds: 1; F/L Amps: 1.95; Rot.: CCW; Bearing Type: Slv; Safety Switch: No; Replaces: 313L5501; Wt. Lbs.: 7.20;
Brand: Fasco Mfg #: A200

Replacement for Trane Draft Inducer Blowers X82-150
Replacement for Trane Draft Inducer Blowers
HP: 1/24; Volts: 208-230; RPM: 3500; F/L Amps: 0.28; Rot.: CW; Bearing Type: Ball; Safety Switch: No; Replaces: 7062-3973; Wt. Lbs.: 4.20;
Brand: Fasco Mfg #: A274

Replacement for Trane Draft Inducer Blowers X82-149
Replacement for Trane Draft Inducer Blowers
HP: 1/8; Volts: 208-230; RPM: 3500; F/L Amps: 0.62; Rot.: CW; Bearing Type: Ball; Safety Switch: No; Replaces: 7062-3972; Wt. Lbs.: 6.00;
Brand: Fasco Mfg #: A273

Replacement for Trane Draft Inducer Blowers X82-147
Replacement for Trane Draft Inducer Blowers
HP: 1/18; Volts: 208-230; RPM: 3500; F/L Amps: 0.62; Rot.: CW; Bearing Type: Ball; Safety Switch: No; Replaces: 7062-3969; Wt. Lbs.: 10.30;
Brand: Fasco Mfg #: A271

Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 2 Ton, R410A B63-654
Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 2 Ton, R410A
Nom. Tons: 2; SEER: 14; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 29-1/2"; Height: 23"; Depth: 22"; Wt. Lbs.: 140;
Brand: First Co Mfg #: 24WCX14-CB

Thru-The-Wall Package Unit First Pak Series, Gas Heat, 80% AFUE, 13 SEER, R410A B64-908
Thru-The-Wall Package Unit First Pak Series, Gas Heat, 80% AFUE, 13 SEER, R410A
Type: Gas Heat; Volts: 208/230V; BtuH Cooling: 24,000; BtuH Heating: 50,000; Air Delivery CFM: 770; Amps Cooling: 21; Width: 27-7/8"; Height: 43-1/4"; Depth: 31-3/8"; Wt. Lbs.: 364;
Brand: First Co Mfg #: FPG50N8C24A

Replacement for Carrier Draft Inducer Blower X83-723
Replacement for Carrier Draft Inducer Blower
Motor Type: Shaded Pole; Volts: 115; RPM: 3200; Speeds: 1; F/L Amps: 1.8; Rot.: CWSE; Bearing Type: Ball; Safety Switch: No; Replaces: 318984-753; Wt. Lbs.: 8.8;
Brand: Packard Mfg #: 66753

Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1-1/2 Ton, R410A B63-653
Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1-1/2 Ton, R410A
Nom. Tons: 1-1/2; SEER: 14; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 29-1/2"; Height: 23"; Depth: 22"; Wt. Lbs.: 134;
Brand: First Co Mfg #: 18WCX14-CB

Thru-The-Wall Package Unit First Pak Series, Gas Heat, 80% AFUE, 12 SEER, R410A B64-912
Thru-The-Wall Package Unit First Pak Series, Gas Heat, 80% AFUE, 12 SEER, R410A
Type: Gas Heat; Volts: 208/230V; BtuH Cooling: 30,000; BtuH Heating: 60,000; Air Delivery CFM: 950; Amps Cooling: 25; Width: 27-7/8"; Height: 43-1/4"; Depth: 31-3/8"; Wt. Lbs.: 367;
Brand: First Co Mfg #: FPG60N8C30A

Thru-the-Wall Condensing Unit 3000 Series, Single-Phase, 2 Ton, R410A B66-541
Thru-the-Wall Condensing Unit 3000 Series, Single-Phase, 2 Ton, R410A
Volts: 208-230/1; BtuH Cooling: 22600; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCP4243000A

Replacement for Intercity Draft Inducer Blower X89-974
Replacement for Intercity Draft Inducer Blower
HP: 1/15; Volts: 115; RPM: 3200; F/L Amps: 2.3; Rot.: CCW; Bearing Type: Ball; Safety Switch: No; Replaces: 1010312, 1010526, 1010928, 1011095, 1011097, 1011409 and 1164280; Wt. Lbs.: 7.00;
Brand: Fasco Mfg #: A170

Thru-the-Wall Condensing Unit 1000 Series, Single-Phase, 2 Ton, R410A B66-540
Thru-the-Wall Condensing Unit 1000 Series, Single-Phase, 2 Ton, R410A
Volts: 208-230/1; BtuH Cooling: 22600; Width: 26-1/4"; Height: 28-5/8"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCP4241000A
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare