208-230, 14, 2-1/2, 2, 12 to 12.8, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE B64-192
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,200; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 970; Min. Circuit Amps: 20.0; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 372;
Brand: Coleman Mfg #: PCG4A300752X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE B64-191
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,200; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 970; Min. Circuit Amps: 18.8; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 352;
Brand: Coleman Mfg #: PCG4A300502X4

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A B60-174
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHE24S41S1

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A B64-143
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,200; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 970; Min. Circuit Amps: 20.0; Max. Fuse Size: 30; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 343;
Brand: Coleman Mfg #: PCE4A3024

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B78-391
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.96; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TH4B2421S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Southwest Region Only B62-067
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 140; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: TW4B3022S

Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A B62-864
Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; BtuH Heating Input: 28,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.54; Min. Circuit Amps: 16.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TE4B3021S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only B62-066
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM TXV…
Brand: Coleman Mfg #: TW4B2422S

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B62-863
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 22,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.68; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth:…
Brand: Coleman Mfg #: TE4B2421S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A B76-580
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX140311

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B61-294
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 145; OEM TXV: B20-469; OEM…
Brand: Evcon Mfg #: RAC14L24B23S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-579
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140251

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B62-882
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 22,200; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.68; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth:…
Brand: Evcon Mfg #: REP14L24B21S

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal B90-040
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 875; Min. Circuit Amps: 15.0; Max. Fuse Size: 20; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPC1424H41

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal B90-041
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; Volts: 208/230; Phase: Single; Motor Type: EEM; Nom. CFM: 1,050; Min. Circuit Amps: 23.0; Max. Fuse Size: 35; Refrigerant: R410A; Width: 66"; Height: 30-1/2"; Depth: 33"; Wt. Lbs.: 350;
Brand: Goodman Mfg #: GPC1430H41

Heat Pump 14 SEER, Single-Phase, 2-1/2 Ton, R410A B79-086
Heat Pump 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 2-1/2; BtuH Cooling: 28,000; BtuH Heating Input: 31,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.87; Min. Circuit Amps: 17.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8;…
Brand: Goodman Mfg #: GSZ140311

Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal B90-046
Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 22,800; Volts: 208/230; Phase: Single; Motor Type: EEM; HSPF: 8.0; COP: 3.8; Nom. CFM: 800; Min. Circuit Amps: 21.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1424H41

Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A B62-883
Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; BtuH Heating Input: 28,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.54; Min. Circuit Amps: 16.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Evcon Mfg #: REP14L30B21S

Single Packaged Heat Pump 14 SEER, Single-Phase, 2.5 Ton, R410A, Horizontal B90-047
Single Packaged Heat Pump 14 SEER, Single-Phase, 2.5 Ton, R410A, Horizontal
SEER: 14; EER: 12; Nom. Tons: 2-1/2; BtuH Cooling: 28,400; BtuH Heating Input: 27,600; Volts: 208/230; Phase: Single; Motor Type: EEM; HSPF: 8.0; COP: 3.8; Nom. CFM: 950; Min. Circuit Amps: 23.0; Refrigerant: R410A; Width: 66"; Height: 30"; Depth: 34"; Wt. Lbs.: 315;
Brand: Goodman Mfg #: GPH1430H41

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R407C B79-031
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R407C
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R407C; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B15-137;…
Brand: Evcon Mfg #: GAW14L30C23S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R407C B79-030
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R407C
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.2; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R407C; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B15-137; OEM TXV…
Brand: Evcon Mfg #: GAW14L24C23S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-747
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140251

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A B76-749
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 180; OEM TXV: B14-850;
Brand: Amana Mfg #: ASX140311

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only B77-433
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TW4B2421S