5, 3-1/2, 12 to 12.8, HVAC Equipment

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-231
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601002X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-232
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 548;
Brand: Coleman Mfg #: PCG6B601252X4

Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A, Connected B66-243
Heat Pump 20 SEER, Single-Phase, 5 Ton, R410A, Connected
SEER: 19; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,500; BtuH Heating Input: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; Min. Circuit Amps: 38.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 33-1/5"; Height: 33-1/5"; Depth: 29…
Brand: Bosch Mfg #: BOVB-60HDN1-M20G

Single Packaged Heat Pump 20 SEER,12.5 EER, Single-Phase, 5 Ton, R410A B62-620
Single Packaged Heat Pump 20 SEER,12.5 EER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,000; BtuH Heating Input: 57,000; Volts: 208/230; Phase: Single; HSPF: 10.0; COP: 3.8; Nom. CFM: 1,800; Min. Circuit Amps: 41.9; Refrigerant: R410A; Width: 44-13/16"; Height: 51-7/16"; Depth: 51-9/16"; Wt. Lbs.: 561;
Brand: Bosch Mfg #: BRB-60HWD1N1-M19

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump LX Series, 14 SEER, Three-Phase, 5 Ton, R410A B79-366
Heat Pump LX Series, 14 SEER, Three-Phase, 5 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 5; HSPF: 9.00; COP: 3.88; Min. Circuit Amps: 21.22; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-1/2"; Depth: 34-1/4"; Wt. Lbs.: 256;
Brand: Coleman Mfg #: THE60B31S

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-230
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 537;
Brand: Coleman Mfg #: PCG6B600652X4

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-688
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.75; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2"; Depth: 38-1/4"; Wt. Lbs.: 270;
Brand: Coleman Mfg #: AC21B6021S

Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-610
Heat Pump 18 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 18; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.44; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC180601

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A B62-223
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 12; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 21.9; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC13L42B24S

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B61-262
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.3; COP: 3.86; Min. Circuit Amps: 25.5; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height:…
Brand: Coleman Mfg #: TH4B4223S

Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-692
Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.78; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height:…
Brand: Coleman Mfg #: HC20B6021S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-910
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 189; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140421

Heat Pump LX Series, 14 SEER, Three-Phase, 5 Ton, R410A B79-367
Heat Pump LX Series, 14 SEER, Three-Phase, 5 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 5; HSPF: 9.00; COP: 3.88; Min. Circuit Amps: 10.33; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-1/2"; Depth: 34-1/4"; Wt. Lbs.: 256;
Brand: Coleman Mfg #: THE60B41S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-662
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 55,500; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.88; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4"; Depth:…
Brand: Coleman Mfg #: TH4B6022S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3-1/2 Ton, R410A B78-421
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 17; EER: 12.75; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 220; OEM TXV: B19-658; OEM…
Brand: Coleman Mfg #: CC7B4221S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 5 Ton, R410A B78-423
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 5 Ton, R410A
SEER: 17; EER: 12; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4"; Depth: 34-1/4"; Wt. Lbs.: 265; OEM TXV: B20-463; OEM TXV…
Brand: Coleman Mfg #: CC7B6021S

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B77-536
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 220; OEM TXV: B19-660; OEM TXV for…
Brand: Evcon Mfg #: RAC14L60B23S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-664
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.92; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-1/2";…
Brand: Evcon Mfg #: RHP14L60B23S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A B73-977
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.5; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 206; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160421

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A B61-260
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A
EER: 12.25; Nom. Tons: 3-1/2; Volts: 208/230; Phase: Three; Min. Circuit Amps: 15.29; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD42B32S

Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A B61-265
Heat Pump LX Series, 14 SEER, Three-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; HSPF: 9.00; COP: 3.62; Min. Circuit Amps: 16.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 230;
Brand: Coleman Mfg #: THE42B32S