17 Results

1, 14 to 14.75, HVAC Equipment

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 3 Ton, R410A B60-666
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 3 Ton, R410A
SEER: 19; EER: 14.75; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 265; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: AC19B3621S

Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-607
Heat Pump 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 5.65; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC180241

Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-608
Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 34,800; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 4.65; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZC180361

Heat Pump 20 SEER, Single-Phase, Modulating, 3 Ton, R410A B79-690
Heat Pump 20 SEER, Single-Phase, Modulating, 3 Ton, R410A
SEER: 20; EER: 14.15; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 11.0; COP: 3.0; Min. Circuit Amps: 25.7; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 32"; Height: 40-1/4"; Depth:…
Brand: Coleman Mfg #: HC20B3621S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 3 Ton, R410A B60-670
Heat Pump 19 SEER, Single-Phase, Two-Stage, 3 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 4.2; Min. Circuit Amps: 21.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B3621S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 2 Ton, R410A B60-669
Heat Pump 19 SEER, Single-Phase, Two-Stage, 2 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.08; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 31-3/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: HC19B2421S

Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 2 Ton, R410A B79-685
Air Conditioning Condensing Unit 20 SEER, Single-Phase, Modulating, 2 Ton, R410A
SEER: 20; EER: 14; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 32"; Height: 40-1/4"; Depth: 35-1/2"; Wt. Lbs.: 194;
Brand: Coleman Mfg #: AC21B2421S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 4 Ton, R410A B60-671
Heat Pump 19 SEER, Single-Phase, Two-Stage, 4 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 4.1; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B4821S

Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-599
Air Conditioning Condensing Unit 18 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 18; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 236; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC180241

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B62-130
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 14; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 19.62; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160; OEM TXV: B19-657; OEM TXV for C Series…
Brand: Evcon Mfg #: RAW14L36B23S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 2 Ton, R410A B60-968
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 2 Ton, R410A
SEER: 17; EER: 14; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 40-1/4"; Depth: 34-1/2"; Wt. Lbs.: 195; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: CC17B2421S

Heat Pump 20 SEER, Variable-Speed, 3 Ton, R410A B78-378
Heat Pump 20 SEER, Variable-Speed, 3 Ton, R410A
SEER: 18; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 35,400; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.0; COP: 4.84; Min. Circuit Amps: 29.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-1/4";…
Brand: Amana Mfg #: AVZC200361

Air Conditioning Condensing Unit 20 SEER, Inverter Drive, Variable-Speed, 2 Ton, R410A B77-235
Air Conditioning Condensing Unit 20 SEER, Inverter Drive, Variable-Speed, 2 Ton, R410A
SEER: 20; EER: 14.5; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.2; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 208; OEM TXV: B18-926;
Brand: Amana Mfg #: AVXC200241

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A B60-969
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A
SEER: 17; EER: 14; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 265; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: CC17B3621S

Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Ton, R410A B91-190
Heat Pump 18 SEER, Two-Stage, Single-Phase, 3 Ton, R410A
SEER: 18; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.5; COP: 4.64; Min. Circuit Amps: 21.9; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4";…
Brand: Amana Mfg #: ASZC180361

Echelon™ Heat Pump 18 SEER, Single-Phase, 2 Ton, R410A B75-599
Echelon™ Heat Pump 18 SEER, Single-Phase, 2 Ton, R410A
SEER: 18; EER: 14; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.8; COP: 4.0; Min. Circuit Amps: 17.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 34"; Height: 40"; Depth:…
Brand: Coleman Mfg #: HC8B024F4C

18 SEER Heat Pump 2 Ton B60-965
18 SEER Heat Pump 2 Ton
SEER: 18; EER: 14; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,00; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 4.26; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 10"; Depth:…
Brand: Amana Mfg #: ASZC180241
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare