554 Results

2-1/2, 1-1/2, HVAC Equipment

Ceiling Fan Coil HX Series, Uncased, Horizontal Recessed, 1-1/2 Ton, 5kW L93-383
Ceiling Fan Coil HX Series, Uncased, Horizontal Recessed, 1-1/2 Ton, 5kW
Nom. Tons: 1-1/2; Nom. CFM: 600; Rows: 4; Volts: 240; Conn. Size: 5/8"; Conn. Size HW: 5/8"; Drain Conn.: 3/4"; kW: 5; Width: 37-1/4"; Height: 10"; Depth: 21"; Wt. Lbs.: 60;
Brand: First Co Mfg #: 19HX5

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-962
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2-1/2; BtuH Cooling: 28,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 156; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXN403010

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A B65-960
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 1-1/2 Ton, R410A
SEER2: 14.3; Nom. Tons: 1-1/2; BtuH Cooling: 17,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 8.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27"; Depth: 26"; Wt. Lbs.: 118; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN401810

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A B61-448
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24"; Height: 32"; Depth: 19"; Wt. Lbs.: 180;
Brand: First Co Mfg #: 30WCXA12-AB

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 1-1/2 Ton, R410A B61-444
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 1-1/2 Ton, R410A
Nom. Tons: 1-1/2; SEER: 12; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24"; Height: 32"; Depth: 19"; Wt. Lbs.: 170;
Brand: First Co Mfg #: 18WCX12-AB

Ceiling Fan Coil HX Series, Uncased, Horizontal Recessed, 2-1/2 Ton, 5kW L93-387
Ceiling Fan Coil HX Series, Uncased, Horizontal Recessed, 2-1/2 Ton, 5kW
Nom. Tons: 2-1/2; Nom. CFM: 1,000; Rows: 4; Volts: 240; Conn. Size: 7/8"; Conn. Size HW: 7/8"; Drain Conn.: 3/4"; kW: 5; Width: 43-1/4"; Height: 10"; Depth: 21"; Wt. Lbs.: 71;
Brand: First Co Mfg #: 30HX5

Evaporator Coil CHPTA Series, Cased Horizontal with TXV - AlumaFin7 B65-570
Evaporator Coil CHPTA Series, Cased Horizontal with TXV - AlumaFin7
Nom. Tons: 1-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 22"; Height: 17-1/2"; Depth: 21"; Wt. Lbs.: 52; Description: Cased; Configuration: Horizontal; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Goodman Mfg #: CHPTA1822B4

Evaporator Coil CAPTA Series, Cased, Upflow/Downflow with TXV - AlumaFin7 B65-266
Evaporator Coil CAPTA Series, Cased, Upflow/Downflow with TXV - AlumaFin7
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14"; Height: 22"; Depth: 21"; Wt. Lbs.: 44; Description: Cased; Configuration: Upflow / Downflow; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Goodman Mfg #: CAPTA3022A4

Evaporator Coil Full Cased, Upflow/Downflow, "A" Type, TXV B65-002
Evaporator Coil Full Cased, Upflow/Downflow, "A" Type, TXV
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14-1/2"; Height: 25-1/2"; Depth: 21-1/2"; Wt. Lbs.: 41; Description: Cased; Configuration: Upflow / Downflow; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Coleman Mfg #: XAFA30DBAN1

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B61-865
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 17-1/2"; Height: 22"; Depth: 21"; Wt. Lbs.: 45; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA3022B6

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B62-367
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14"; Height: 22"; Depth: 21"; Wt. Lbs.: 41; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA3022A6

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B60-890
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 1-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14"; Height: 18"; Depth: 21"; Wt. Lbs.: 33; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Color: Grey; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA1818A6

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B61-866
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 21"; Height: 22"; Depth: 21"; Wt. Lbs.: 50; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA3022C6

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B62-816
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14"; Height: 22"; Depth: 21"; Wt. Lbs.: 41; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA2922A6

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B62-817
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 17-1/2"; Height: 22"; Depth: 21"; Wt. Lbs.: 45; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA2922B6

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B60-891
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 1-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 17-1/2"; Height: 18"; Depth: 21"; Wt. Lbs.: 38; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Color: Grey; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA1818B6

Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7 B62-818
Evaporator Coil CAPFA Series - Cased, Upflow/Downflow - AlumaFin7
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 21"; Height: 22"; Depth: 21"; Wt. Lbs.: 50; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Coil Type: Cased; TXV Included: No;
Brand: Goodman Mfg #: CAPFA2922C6

Manufactured Housing Coil CM Series Uncased Downflow B78-867
Manufactured Housing Coil CM Series Uncased Downflow
Nom. Tons: 2-1/2; Metering Device: R410A TXV; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 17-3/4"; Height: 19-1/2"; Depth: 19-5/8"; Wt. Lbs.: 40;
Brand: Aspen Manufacturing Mfg #: CM30C34-177L-000

Cased Upflow/Downflow Evaporator Coil - CC Series Coleman/Evcon Matches - Champagne Paint B61-977
Cased Upflow/Downflow Evaporator Coil - CC Series Coleman/Evcon Matches - Champagne Paint
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14-1/2"; Height: 16"; Depth: 21-1/2"; Wt. Lbs.: 44; Description: Cased; Configuration: Upflow / Downflow; Metering Device: TXV; Color: Champagne; Coil Type: Cased; TXV Included: Yes;
Brand: Aspen Manufacturing Mfg #: CC30A34-145L-055

Cased Upflow/Downflow Evaporator Coil - CC Series Coleman/Evcon Matches - Champagne Paint B61-979
Cased Upflow/Downflow Evaporator Coil - CC Series Coleman/Evcon Matches - Champagne Paint
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 17-1/2"; Height: 16"; Depth: 21-1/2"; Wt. Lbs.: 44; Description: Cased; Configuration: Upflow / Downflow; Metering Device: TXV; Color: Champagne; Coil Type: Cased; TXV Included: Yes;
Brand: Aspen Manufacturing Mfg #: CC30A34-175L-055

Ceiling Fan Coil CDX-HW Series, Uncased, Horizontal Recessed, 1-1/2 Ton, Hot Water L93-409
Ceiling Fan Coil CDX-HW Series, Uncased, Horizontal Recessed, 1-1/2 Ton, Hot Water
Nom. Tons: 1-1/2; Nom. CFM: 710; Rows: 3; Volts: 120; Conn. Size: 5/8"; Conn. Size HW: 5/8"; Drain Conn.: 3/4"; Width: 21"; Height: 10"; Depth: 38"; Wt. Lbs.: 62;
Brand: First Co Mfg #: 19CDX-HW

Cased Upflow/Downflow Evaporator Coil - CC Series Coleman/Evcon Matches - Champagne Paint B61-976
Cased Upflow/Downflow Evaporator Coil - CC Series Coleman/Evcon Matches - Champagne Paint
Nom. Tons: 2-1/2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14-1/2"; Height: 16"; Depth: 21-1/2"; Wt. Lbs.: 44; Description: Cased; Configuration: Upflow / Downflow; Metering Device: Flowrater; Color: Champagne; Coil Type: Cased; TXV Included: No;
Brand: Aspen Manufacturing Mfg #: CC30A3G-145L-055

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A B65-534
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2-1/2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 13.4; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 165; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCE2B30S21S

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A B61-449
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26"; Height: 28"; Depth: 19"; Wt. Lbs.: 180;
Brand: First Co Mfg #: 30WCXA12-BB
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare