Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-356
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.2; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-357
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 460; Phase: Three; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B41S

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A B74-111
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301;
Brand: Daikin Mfg #: DX13SA0603

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A B74-112
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 460; Phase: Three; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301;
Brand: Daikin Mfg #: DX13SA0604

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A B74-084
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 14.1; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 28-3/4"; Depth: 29"; Wt. Lbs.: 196;
Brand: Daikin Mfg #: DX13SA0363

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A B78-971
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 3 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 460; Phase: Three; Min. Circuit Amps: 7.9; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 28-3/4"; Depth: 29"; Wt. Lbs.: 196;
Brand: Daikin Mfg #: DX13SA0364

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 208/230V B91-946
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 208/230V
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: 3; Min. Circuit Amps: 17.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215;
Brand: Coleman Mfg #: TCHD36S43S3

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 5 Ton, R410A, 208/230V B91-948
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 5 Ton, R410A, 208/230V
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: 3; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 250;
Brand: Coleman Mfg #: TCHD60S43S3

Single Packaged Air Conditioner 13 SEER, Three-Phase, 5 Ton, R410A, Multi-Position B74-134
Single Packaged Air Conditioner 13 SEER, Three-Phase, 5 Ton, R410A, Multi-Position
SEER: 13; EER: 10.9; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Three; Motor Type: EEM; Nom. CFM: 1,750; Min. Circuit Amps: 29.0; Max. Fuse Size: 40; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 445; BtuH Heating Input: 60,000;
Brand: Daikin Mfg #: DP13CM6043

Single Packaged Air Conditioner 13 SEER, Three-Phase, 3 Ton, R410A, Multi-Position B74-132
Single Packaged Air Conditioner 13 SEER, Three-Phase, 3 Ton, R410A, Multi-Position
SEER: 13; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 35,000; Volts: 208/230; Phase: Three; Motor Type: EEM; Nom. CFM: 1,180; Min. Circuit Amps: 17.5; Max. Fuse Size: 25; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 365; BtuH Heating Input: 36,000;
Brand: Daikin Mfg #: DP13CM3643

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 460V B91-950
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 3 Ton, R410A, 460V
SEER: 13; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 460; Phase: 3; Min. Circuit Amps: 8.8; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215;
Brand: Coleman Mfg #: TCHD36S44S3