102 Results

16, 12, 5, 3, 2-1/2, HVAC Equipment

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A B61-448
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24"; Height: 32"; Depth: 19"; Wt. Lbs.: 180;
Brand: First Co Mfg #: 30WCXA12-AB

Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A B61-449
Air Conditioning Condensing Unit Thru-The-Wall-12 SEER, Single-Phase, 2-1/2 Ton, R410A
Nom. Tons: 2-1/2; SEER: 12; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26"; Height: 28"; Depth: 19"; Wt. Lbs.: 180;
Brand: First Co Mfg #: 30WCXA12-BB

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-226
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,200; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360752X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-232
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 548;
Brand: Coleman Mfg #: PCG6B601252X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-231
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601002X4

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B61-218
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3621S

Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A B61-217
Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.22; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3021S

Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-612
Heat Pump 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 4.4; Min. Circuit Amps: 19.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZC160361

Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A B61-614
Heat Pump 16 SEER, Two-Stage, Single-Phase, 5 Tons, R410A
SEER: 16; EER: 12.50; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.83; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZC160601

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-230
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 537;
Brand: Coleman Mfg #: PCG6B600652X4

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B73-975
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 149; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160301

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B77-554
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.99; Min. Circuit Amps: 18.9; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 40"; Depth:…
Brand: Goodman Mfg #: GSZ160361

Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A B61-350
Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A
Nom. Tons: 2.5; SEER: 12; EER: 10.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 24-1/8"; Height: 32"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-430-3010

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B75-681
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 155; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160311

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A B61-604
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 3 Tons, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-3/4"; Height: 36-1/2"; Depth: 35-3/4"; Wt. Lbs.: 201; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC160361

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B77-557
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.45; Min. Circuit Amps: 37.0; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 40";…
Brand: Goodman Mfg #: GSZ160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B73-976
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160361

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A B73-979
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 54,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 29.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 279; OEM TXV: B18-727;
Brand: Goodman Mfg #: GSX160601

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B75-682
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 20.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 182; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX160371

Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A B77-553
Heat Pump 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.73; Min. Circuit Amps: 18.0; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160301

Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A B64-149
Single Packaged Air Conditioner 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,275; Min. Circuit Amps: 23.2; Max. Fuse Size: 35; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 461;
Brand: Coleman Mfg #: PCE6A3624

Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A B61-347
Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A
Nom. Tons: 2.5; SEER: 12; EER: 10.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 26-1/4"; Height: 28-5/8"; Depth: 18-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-430-1010

Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A B61-353
Air Conditioning Condensing Unit Thru-The-Wall 12 SEER, Single-Phase, 2.5 TON, R410A
Nom. Tons: 2.5; SEER: 12; EER: 10.5; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 30"; Height: 23"; Depth: 22-1/2"; Wt. Lbs.: 180;
Brand: National Comfort Products Mfg #: NCPE-430-4010
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare