UNITED STATES, 3, 1, 5, 3, HVAC Equipment

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-963
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt. Lbs.: 188; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXN403610

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-966
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; Nom. Tons: 5; BtuH Cooling: 55,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN406010

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-258
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 208/230; Phase: Three; Min. Circuit Amps: 14.34; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B32S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-356
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.2; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A B79-357
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 5; Volts: 460; Phase: Three; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205;
Brand: Coleman Mfg #: TCD60B41S

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-226
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,200; Min. Circuit Amps: 23.2; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 466;
Brand: Coleman Mfg #: PCG6A360752X4

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3 Ton, R410A B66-328
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.5; Min. Circuit Amps: 21.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB403610

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-232
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 548;
Brand: Coleman Mfg #: PCG6B601252X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-202
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 475;
Brand: Coleman Mfg #: PCG4B601002X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V B64-206
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 17.7; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 383;
Brand: Coleman Mfg #: PCG4A361003X4

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-685
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXH506010

Heat Pump 15.2 SEER2, Single-Phase, 3 Ton, R410A B65-701
Heat Pump 15.2 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 15.2; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 22.8; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH503610

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A B61-259
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3 Ton, R410A
EER: 12.25; Nom. Tons: 3; Volts: 460; Phase: Three; Min. Circuit Amps: 7.85; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 160;
Brand: Coleman Mfg #: TCD36B42S

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-952
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 224; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXB403610

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-231
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 59,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,825; Min. Circuit Amps: 38.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 541;
Brand: Coleman Mfg #: PCG6B601002X4

Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A B66-331
Heat Pump GSZB4 Series, 14.3 SEER2, 7.5HSPF2, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF2: 7.5; COP: 3.7; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-10/16"; Depth:…
Brand: Goodman Mfg #: GSZB406010

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A B65-723
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 3 Ton, R410A
SEER2: 17.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 24.1; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 216; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXC703610

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 208/230V B64-212
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 25.2; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600653X4

Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A B65-704
Heat Pump 15.2 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 15.2; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 7.8; Min. Circuit Amps: 30.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt.…
Brand: Goodman Mfg #: GSZH506010

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A B74-111
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301;
Brand: Daikin Mfg #: DX13SA0603

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-149
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.75; Nom. Tons: 3; BtuH Cooling: 34,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.72; Min. Circuit Amps: 21.99; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3622S

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-955
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 305; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXB406010

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A B74-112
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 460; Phase: Three; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301;
Brand: Daikin Mfg #: DX13SA0604

Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A B61-218
Heat Pump 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B3621S