356 Results

1, 5, 3, HVAC Equipment

Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A B60-672
Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 3.86; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B6021S

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A B60-175
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE36S41S1

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-201
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600652X4

Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A B79-692
Heat Pump 20 SEER, Single-Phase, Modulating, 5 Ton, R410A
SEER: 20; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.78; Min. Circuit Amps: 33.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height:…
Brand: Coleman Mfg #: HC20B6021S

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position B66-154
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 3 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,200; Min. Circuit Amps: 22.8; Refrigerant: R410A; Width: 47"; Height: 32"; Depth: 51"; Wt. Lbs.: 458;
Brand: Goodman Mfg #: GPGM33608041

Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A, Multi-Position B66-344
Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 3 Ton, R410A, Multi-Position
SEER2: 13.4; Nom. Tons: 3; BtuH Cooling: 34,200; BtuH Heating Input: 33,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.58; Nom. CFM: 1,200; Min. Circuit Amps: 24.4; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 400;
Brand: Goodman Mfg #: GPHM33641

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3 Ton, R410A B98-347
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 3 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 3; BtuH Cooling: 36,800; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 118; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX130361

Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A B64-281
Heat Pump 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 4.28; Min. Circuit Amps: 19.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth:…
Brand: Goodman Mfg #: GSZ140361

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE B64-193
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,165; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 359;
Brand: Coleman Mfg #: PCG4A360502X4

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 3 Ton, R410A B66-583
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 13.4; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 153; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXN3N3610

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-745
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 32,600; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; HSPF2: 8.2; COP: 3.42; Min. Circuit Amps: 20.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 31-3/4"; Height: 33-1/4";…
Brand: Coleman Mfg #: THE2B36T21S

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B98-350
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130601

Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A B75-919
Heat Pump 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/2";…
Brand: Goodman Mfg #: GSZ140601

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B62-070
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 29.1; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 190; OEM TXV: B19-660;…
Brand: Coleman Mfg #: TC3B6022S

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A B65-959
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 3 Ton, R410A
SEER2: 14.3; Nom. Tons: 3; BtuH Cooling: 34,400; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 202; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSXM403610

Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 5 Ton, R410A B65-725
Air Conditioning Condensing Unit 17.2 SEER2, Two-Stage, Single-Phase, 5 Ton, R410A
SEER2: 17.2; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 41-5/8"; Depth: 35-1/2"; Wt. Lbs.: 283; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXC706010

Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 5 Ton, R410A, Multi-Position B66-347
Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 5 Ton, R410A, Multi-Position
SEER2: 13.4; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 55,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.38; Nom. CFM: 1,850; Min. Circuit Amps: 37.5; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 495;
Brand: Goodman Mfg #: GPHM36041

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3 Ton, R410A B62-222
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 3; BtuH Cooling: 35,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 19.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24; Height: 33-1/4"; Depth: 24; Wt. Lbs.: 145; OEM TXV: B19-657; OEM TXV for C Series Coils:…
Brand: Evcon Mfg #: RAC13L36B24S

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410A B65-748
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 14.3; Nom. Tons: 5; BtuH Cooling: 55,000; BtuH Heating Input: 54,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; HSPF2: 8.2; COP: 3.6; Min. Circuit Amps: 30.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 46";…
Brand: Coleman Mfg #: THE2B60T21S

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A B64-414
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 3 Ton, R410A
SEER: 18; EER: 10; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.4; Min. Circuit Amps: 23; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 37-3/8"; Height: 33"; Depth:…
Brand: Coleman Mfg #: HMH72B361S

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A B66-586
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.4; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 227; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN3N6010

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A B77-529
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-660; OEM…
Brand: Evcon Mfg #: RAC13L60B23S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A B78-420
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3 Ton, R410A
SEER: 17; EER: 12.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 175; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: CC7B3621S

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 3 Ton, R410a B66-137
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 3 Ton, R410a
SEER2: 14.3; EER2: 11; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 32,600; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 7.5; COP: 3.42; Min. Circuit Amps: 20.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 31-3/4"; Height: 33-1/4";…
Brand: Evcon Mfg #: RHP14336B21S