Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A B77-418
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 28.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 165; OEM TXV: B19-659; OEM TXV…
Brand: Coleman Mfg #: TC3B4821S

Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A B75-918
Heat Pump 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.5; COP: 4.72; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 29"; Height: 36-1/4";…
Brand: Goodman Mfg #: GSZ140481

Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 4 Ton, R410A, Multi-Position B66-346
Single Packaged Heat Pump GPHM3 Series, 13.4 SEER2, Single-Phase, 4 Ton, R410A, Multi-Position
SEER2: 13.4; Nom. Tons: 4; BtuH Cooling: 47,500; BtuH Heating Input: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; COP: 3.54; Nom. CFM: 1,600; Min. Circuit Amps: 31.9; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 495;
Brand: Goodman Mfg #: GPHM34841

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 4 Ton, R410A B65-556
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 4; BtuH Cooling: 47,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 24; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-1/4"; Height: 33-1/4"; Depth: 35-1/4"; Wt. Lbs.: 210; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC14348B21S

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 4 Ton, R410A B65-747
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 14.3; Nom. Tons: 4; BtuH Cooling: 45,000; BtuH Heating Input: 43,500; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; HSPF2: 8.2; COP: 3.6; Min. Circuit Amps: 26.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-3/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: THE2B48T21S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A B77-528
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 28.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 175; OEM TXV: B19-659; OEM TXV…
Brand: Evcon Mfg #: RAC13L48B23S

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 4 Ton, R410A B66-585
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 13.4; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 24.4; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt. Lbs.: 215; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN3N4810

Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 4 Ton, R410A B64-415
Horizontal Discharge Heat Pump 17 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 18; EER: 10.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 46,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 3.34; Min. Circuit Amps: 36; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 37-3/8"; Height: 54-5/8";…
Brand: Coleman Mfg #: HMH72B481S

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position B66-159
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 4; BtuH Cooling: 46,250; BtuH Heating Input: 100,000; BtuH Heating Output: 81,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,525; Min. Circuit Amps: 32.3; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 528;
Brand: Goodman Mfg #: GPGM34810041

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-661
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.25; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.66; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Coleman Mfg #: TH4B4822S

Single Packaged Gas/Electric  Air Conditioner 13.4 SEER2, Single-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position B66-158
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 4 Ton, 81% AFUE, R410A, Multi-Position
SEER2: 13.4; EER2: 10.6; Nom. Tons: 4; BtuH Cooling: 46,250; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,525; Min. Circuit Amps: 32.3; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 523;
Brand: Goodman Mfg #: GPGM34808041

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 4 Ton, R410A B78-422
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 4 Ton, R410A
SEER: 17; EER: 12.75; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 25.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 220; OEM TXV: B19-659; OEM TXV…
Brand: Coleman Mfg #: CC7B4821S

Horizontal Discharge Air Conditioning Condensing Unit 16.5 SEER2, Single-Phase, Modulating, 4 Ton, R410A B66-301
Horizontal Discharge Air Conditioning Condensing Unit 16.5 SEER2, Single-Phase, Modulating, 4 Ton, R410A
SEER2: 16.5; EER2: 10.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 35.0; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 37-3/8"; Height: 54-5/8"; Depth: 13-3/8"; Wt. Lbs.: 206; OEM TXV: B19-659; OEM TXV for X…
Brand: Coleman Mfg #: HMCG22B481S

Heat Pump 15.2 SEER2, Single-Phase, 4 Ton, R410A B66-564
Heat Pump 15.2 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 15.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 243; OEM…
Brand: Coleman Mfg #: THF2B48T21S

Air Conditioning Condensing Unit LX Series, 15.2 SEER2, Single-Phase, 4 Ton, R410A B66-279
Air Conditioning Condensing Unit LX Series, 15.2 SEER2, Single-Phase, 4 Ton, R410A
SEER2: 15.2; EER2: 12.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.8; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 250; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TCF2B48T21S

Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 4 Ton, 81% AFUE, R410A, Ultra LoNOx B66-178
Single Packaged Gas/Electric Air Conditioner 13.4 SEER2, Single-Phase, 4 Ton, 81% AFUE, R410A, Ultra LoNOx
SEER2: 13.4; EER2: 10.6; Nom. Tons: 4; BtuH Cooling: 46,250; BtuH Heating Input: 80,000; BtuH Heating Output: 64,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,525; Min. Circuit Amps: 32.3; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 533;
Brand: Goodman Mfg #: GPUM34808041

Heat Pump LX Series, 14.3 SEER2, Single-Phase, 4 Ton, R410a B66-139
Heat Pump LX Series, 14.3 SEER2, Single-Phase, 4 Ton, R410a
SEER2: 14.3; EER2: 11; Nom. Tons: 4; BtuH Cooling: 45,000; BtuH Heating Input: 43,500; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 7.5; COP: 3.62; Min. Circuit Amps: 26.1; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-3/4"; Height: 39-1/2";…
Brand: Evcon Mfg #: RHP14348B21S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A B75-911
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140481

Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A B77-556
Heat Pump 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 4.75; Min. Circuit Amps: 26.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 34-5/8";…
Brand: Goodman Mfg #: GSZ160481

Dual Fuel Packaged Unit 13.4 SEER2, Single-Phase, 4 Ton, R410A, 81% AFUE, 6.7 HSPF2 B66-173
Dual Fuel Packaged Unit 13.4 SEER2, Single-Phase, 4 Ton, R410A, 81% AFUE, 6.7 HSPF2
SEER2: 13.4; EER2: 10.6; Nom. Tons: 4; BtuH Cooling: 44,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF2: 6.7; Nom. CFM: 1,300; Min. Circuit Amps: 31.7; Refrigerant: R410A; Width: 47"; Height: 40"; Depth: 51"; Wt. Lbs.: 525;
Brand: Goodman Mfg #: GPDM34810041

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-663
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.62; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: RHP14L48B23S

Single Packaged Heat Pump 14 SEER, Single-Phase, 4 Tons, R410A, Multi-Position B76-805
Single Packaged Heat Pump 14 SEER, Single-Phase, 4 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 45,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,600; Min. Circuit Amps: 34.5; Refrigerant: R410A; Width: 47"; Height: 42-3/4"; Depth: 51"; Wt. Lbs.: 485;
Brand: Goodman Mfg #: GPH1448M41

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B77-535
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.75; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 35-1/4"; Wt. Lbs.: 215; OEM TXV: B19-659; OEM…
Brand: Evcon Mfg #: RAC14L48B23S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A B73-978
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 4 Ton, R410A
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 45,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 219; OEM TXV: B18-726;
Brand: Goodman Mfg #: GSX160481