1118 Results

1, HVAC Equipment

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A B60-174
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHE24S41S1

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A B60-175
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 215; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE36S41S1

Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A B60-176
Air Conditioning Condensing Unit Horizontal Discharge, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 24.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240; OEM TXV: B20-259; OEM TXV for…
Brand: Coleman Mfg #: TCHE48S41S1

Air Conditioning Condensing Unit 18 SEER, Single-Phase, 2 Ton, R410A B60-194
Air Conditioning Condensing Unit 18 SEER, Single-Phase, 2 Ton, R410A
SEER: 18; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,400; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 214; OEM TXV: B18-099;
Brand: Amana Mfg #: ASXC180241

Air Conditioning Condensing Unit 18 SEER, Single-Phase, 3 Ton, R410A B60-195
Air Conditioning Condensing Unit 18 SEER, Single-Phase, 3 Ton, R410A
SEER: 18; EER: 13.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 19.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-3/4"; Height: 40"; Depth: 35-3/4"; Wt. Lbs.: 216; OEM TXV: B14-850;
Brand: Amana Mfg #: ASXC180361

Air Conditioning Condensing Unit 18 SEER, Single-Phase, 4 Ton, R410A B60-196
Air Conditioning Condensing Unit 18 SEER, Single-Phase, 4 Ton, R410A
SEER: 18; EER: 13.25; Nom. Tons: 4; BtuH Cooling: 47,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 276; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC180481

Air Conditioning Condensing Unit 18 SEER, Single-Phase, 5 Ton, R410A B60-197
Air Conditioning Condensing Unit 18 SEER, Single-Phase, 5 Ton, R410A
SEER: 18; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.0; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-3/4"; Height: 42-1/4"; Depth: 35-3/4"; Wt. Lbs.: 304; OEM TXV: B14-851;
Brand: Amana Mfg #: ASXC180601

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-661
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.25; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.66; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Coleman Mfg #: TH4B4822S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-662
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 55,500; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.88; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4"; Depth:…
Brand: Coleman Mfg #: TH4B6022S

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-663
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.62; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: RHP14L48B23S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-664
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.92; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-1/2";…
Brand: Evcon Mfg #: RHP14L60B23S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 2 Ton, R410A B60-665
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 2 Ton, R410A
SEER: 19; EER: 15.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 40-1/4"; Depth: 34-1/2"; Wt. Lbs.: 195; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: AC19B2421S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 3 Ton, R410A B60-666
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 3 Ton, R410A
SEER: 19; EER: 14.75; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 21.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 265; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: AC19B3621S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A B60-667
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 4 Ton, R410A
SEER: 19; EER: 13.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: AC19B4821S

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A B60-668
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659;…
Brand: Coleman Mfg #: AC19B6021S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 2 Ton, R410A B60-669
Heat Pump 19 SEER, Single-Phase, Two-Stage, 2 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.5; COP: 4.08; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 31-3/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: HC19B2421S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 3 Ton, R410A B60-670
Heat Pump 19 SEER, Single-Phase, Two-Stage, 3 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 4.2; Min. Circuit Amps: 21.4; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B3621S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 4 Ton, R410A B60-671
Heat Pump 19 SEER, Single-Phase, Two-Stage, 4 Ton, R410A
SEER: 19; EER: 14.0; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 4.1; Min. Circuit Amps: 28.2; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B4821S

Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A B60-672
Heat Pump 19 SEER, Single-Phase, Two-Stage, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.6; COP: 3.86; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC19B6021S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 1-1/2 Ton, R410A B60-819
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 8.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 135; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S181

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B60-820
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 132; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B60-821
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.0; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 35-3/4"; Depth: 29"; Wt. Lbs.: 149; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S301

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A B60-822
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3; BtuH Cooling: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 39-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX16S361

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A B60-823
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.3; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 35-3/4"; Depth: 35-1/2"; Wt. Lbs.: 206; OEM TXV: B18-725;
Brand: Goodman Mfg #: GSX16S421
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare