496 Results

14, HVAC Equipment

Heat Pump LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A B78-390
Heat Pump LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 1-1/2; BtuH Cooling: 17,800; BtuH Heating Input: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.84; Min. Circuit Amps: 12.0; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height:…
Brand: Coleman Mfg #: TH4B1821S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A, Southeast & Northern Region Only B61-254
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 145; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TC4B3622S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V B64-207
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3-1/2 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,350; Min. Circuit Amps: 20.4; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 398;
Brand: Coleman Mfg #: PCG4A420753X4

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3 Ton, R410A B75-909
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 3; BtuH Cooling: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 162; OEM TXV: B14-850;
Brand: Goodman Mfg #: GSX140361

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B78-393
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 3; BtuH Cooling: 35,200; BtuH Heating Input: 35,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.76; Min. Circuit Amps: 20.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: TH4B3521S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A, Southeast & Northern Region Only B61-251
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 1-1/2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 12.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 30"; Depth: 24"; Wt. Lbs.: 125; OEM TXV: B20-469; OEM TXV for…
Brand: Coleman Mfg #: TC4B1822S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Southeast & Northern Region Only B61-253
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 140; OEM TXV: B19-657;…
Brand: Coleman Mfg #: TC4B3022S

Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A B60-662
Heat Pump LX Series, 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 12; Nom. Tons: 5; BtuH Cooling: 55,500; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.88; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-3/4"; Depth:…
Brand: Coleman Mfg #: TH4B6022S

Heat Pump LX Series, 14 SEER, Three-Phase, 5 Ton, R410A B79-367
Heat Pump LX Series, 14 SEER, Three-Phase, 5 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 5; HSPF: 9.00; COP: 3.88; Min. Circuit Amps: 10.33; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 42-1/2"; Depth: 34-1/4"; Wt. Lbs.: 256;
Brand: Coleman Mfg #: THE60B41S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 1-1/2 Ton, R410A B61-450
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 1-1/2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 1-1/2; BtuH Cooling: 18,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 8.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 25-3/4"; Depth: 23"; Wt. Lbs.: 126; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140181

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only B77-431
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 5 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 31.7; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 36-1/4"; Depth: 34-1/4"; Wt. Lbs.: 205; OEM TXV: B19-660; OEM…
Brand: Coleman Mfg #: TC4B6021S

Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1 Ton, R410A B63-652
Air Conditioning Condensing Unit Thru-The-Wall-14 SEER, Single-Phase, 1 Ton, R410A
Nom. Tons: 1; SEER: 14; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 29-1/2"; Height: 23"; Depth: 22"; Wt. Lbs.: 125;
Brand: First Co Mfg #: 12WCX14-CB

Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A B78-400
Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 13.0; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; BtuH Heating Input: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.5; COP: 4.06; Min. Circuit Amps: 18.1; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Evcon Mfg #: RHP14L30B23S

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B62-865
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 35,000; BtuH Heating Input: 34,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.55; COP: 3.40; Min. Circuit Amps: 19.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TE4B3621S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A B75-911
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 26.4; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/4"; Depth: 35-1/2"; Wt. Lbs.: 220; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140481

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V B64-215
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 3 Ton, R410A, 81% AFUE, 460V
SEER: 14; EER: 11.8; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,165; Min. Circuit Amps: 7.6; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 359;
Brand: Coleman Mfg #: PCG4A360504X4

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-910
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 189; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140421

Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A B61-150
Heat Pump LX Series, 14 SEER, Single-Phase, 3 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 3; BtuH Cooling: 36,000; BtuH Heating Input: 36,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.76; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: RHP14L36B23S

Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A B78-399
Heat Pump LX Series, 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.5; COP: 3.98; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Evcon Mfg #: RHP14L24B23S

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B61-298
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 11.8; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.5; COP: 3.34; Min. Circuit Amps: 26.8; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Evcon Mfg #: RHP14L42B24S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 460V B64-221
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 5 Ton, R410, 81% AFUE, 460V
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 460; Phase: Three; Motor Type: ECM; Nom. CFM: 1,810; Min. Circuit Amps: 12.0; Refrigerant: R410A; Width: 45-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 469;
Brand: Coleman Mfg #: PCG4B600654X4

Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position B76-801
Single Packaged Heat Pump 14 SEER, Single-Phase, 2 Tons, R410A, Multi-Position
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 850; Min. Circuit Amps: 21.8; Refrigerant: R410A; Width: 47"; Height: 34-3/4"; Depth: 51"; Wt. Lbs.: 380;
Brand: Goodman Mfg #: GPH1424M41

Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V B64-210
Single Packaged Gas/Heat Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A, 81% AFUE, 208/230V
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 20.2; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 456;
Brand: Coleman Mfg #: PCG4B481003X4