Remote Bulb Temperature Control L38-684
Remote Bulb Temperature Control
Sensing Element: 6' Remote (3/8" x 4"); Temp. Range: -30°F to +100°F; Switch Action: SPST; Diff.: 3° to 12°;
Brand: Johnson Controls Mfg #: A19ABA-40C

Refrigeration and Beverage Cooler Cold Control B13-240
Refrigeration and Beverage Cooler Cold Control
Sensing Element: 48"; Normal On Temp.: 40.0°F; Normal Off Temp.: 32.0°F; Cold Off Temp.: 30.0°F; Warm On Temp.: 42.0°F; Switch Action: SPST; Diff.: 8.0°F;
Brand: Ranco Mfg #: A30-2210

Pressure Control B18-812
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 20; Cutout PSI: 5; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AC-1C

Pressure Control B18-818
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 50; Cutout PSI: 25; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-12C

Pressure Control B18-824
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 90; Cutout PSI: 50; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-361C

Pressure Control B18-816
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 30; Cutout PSI: 15; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AC-2C

Adaptable Refrigerator Control B10-360
Adaptable Refrigerator Control
Sensing Element: 84"; Cold On Temp.: 38.0°F; Cold Off Temp.: 32.0°F; Warm On Temp.: 61.0°F; Switch Action: SPST; Diff.: 6.0°F;
Brand: Ranco Mfg #: A30-261

Pressure Control B18-821
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 60; Cutout PSI: 35; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-2C

Pressure Control B18-814
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 25; Cutout PSI: 10; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-15C

Pressure Control B18-813
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 30; Cutout PSI: 5; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-355C

Pressure Control B18-817
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 45; Cutout PSI: 20; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-356C

Pressure Control B18-815
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 32; Cutout PSI: 10; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-201C

Pressure Control B18-820
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 60; Cutout PSI: 30; Conn.: 78" Leads;
Brand: Johnson Controls Mfg #: P100AP-105C

Adaptable Constant Differential Control B13-239
Adaptable Constant Differential Control
Sensing Element: 84"; Normal On Temp.: 5.5°F; Normal Off Temp.: -3.0°F; Cold Off Temp.: -24.0°F; Warm On Temp.: 20.5°F; Switch Action: SPST; Diff.: 8.5°F;
Brand: Ranco Mfg #: A30-301

Pressure Control B18-823
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 80; Cutout PSI: 40; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-357C

Adaptable Refrigerator Control B10-361
Adaptable Refrigerator Control
Sensing Element: 84"; Normal On Temp.: 32.0°F; Normal Off Temp.: 20.0°F; Cold On Temp.: 15.0°F; Cold Off Temp.: 3.0°F; Warm On Temp.: 43.0°F; Switch Action: SPST; Diff.: 12.0°F;
Brand: Ranco Mfg #: A30-262

Pressure Control B18-819
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 80; Cutout PSI: 25; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-9C

Pressure Control B18-822
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 60; Cutout PSI: 40; Conn.: 36" Leads;
Brand: Johnson Controls Mfg #: P100AP-10C

Low Temperature Cut-Out (Freeze-Stat) B13-348
Low Temperature Cut-Out (Freeze-Stat)
Switch Action: SPST; Diff.: Manual Reset;
Brand: Johnson Controls Mfg #: A11A-1C

Refrigeration/Freezer Control B10-387
Refrigeration/Freezer Control
Sensing Element: 72"; Cold On Temp.: 30.0°F; Cold Off Temp.: 25.0°F; Warm On Temp.: 44.0°F; Switch Action: SPST; Diff.: 5.0°F;
Brand: Ranco Mfg #: A22-1112

Ice Machine Control B13-242
Ice Machine Control
Temp. Range: 27°F to 49°F; Diff.: 5.5°F; Capillary Length: 60" Cap.; Switch Action: SPST;
Brand: Ranco Mfg #: A30-3815

Adaptable Refrigerator Control B10-359
Adaptable Refrigerator Control
Sensing Element: 72"; Normal On Temp.: 22.0°F; Normal Off Temp.: 16.0°F; Cold On Temp.: 5.5°F; Cold Off Temp.: 0.5°F; Warm On Temp.: 30.0°F; Switch Action: SPST; Diff.: 6.0°F;
Brand: Ranco Mfg #: A30-260

Low Temperature Cut-Out (Freeze-Stat) B13-650
Low Temperature Cut-Out (Freeze-Stat)
Switch Action: SPST; Diff.: 8°F;
Brand: Johnson Controls Mfg #: A11B-1C

Commercial Refrigeration and Freezer Control B13-289
Commercial Refrigeration and Freezer Control
Sensing Element: 72"; Normal On Temp.: 33.5°F; Normal Off Temp.: 11.0°F; Cold On Temp.: 5.5°F; Cold Off Temp.: 0.5°F; Warm On Temp.: 47.0°F; Switch Action: SPST; Diff.: 22.5°F;
Brand: Ranco Mfg #: A30-263