41 Results

Secop, MARS, Software, Training, Testing, Tools & Training, Temperature & Humidity Measurement, Test Instruments, Refrigeration

Direct Replacement Relay for Copeland B13-471
Direct Replacement Relay for Copeland
Volts: 375; Continuous Volt: 375; Pick-Up Volt Min.: 180; Pick-Up Volt Max.: 195; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 105; Replaces: (0)940-0001-55;
Brand: MARS Mfg #: 16023

Direct Replacement Relay for Copeland B13-472
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 180; Pick-Up Volt Max.: 195; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 105; Replaces: (0)940-0001-60;
Brand: MARS Mfg #: 16091

Battery Driven Compressor B82-352
Battery Driven Compressor
HP: 1/12; BtuH Capacity @ -10°F Evap.: 142; BtuH Capacity @ 10°F Evap.: 273; BtuH Capacity @ 25°F Evap.: 410; Suction Conn.: 1/4"; Discharge Conn.: 1/4"; Compressor: Reciprocating; Application: Medium Temperature;
Brand: Secop Mfg #: BD50F510

Battery Driven Compressor B82-351
Battery Driven Compressor
HP: 1/20; BtuH Capacity @ -10°F Evap.: 113; BtuH Capacity @ 10°F Evap.: 214; BtuH Capacity @ 25°F Evap.: 320; Suction Conn.: 1/4"; Discharge Conn.: 1/4"; Compressor: Reciprocating; Application: Medium Temperature;
Brand: Secop Mfg #: BD35F510

Potential Relay Universal Replacement B13-308
Potential Relay Universal Replacement
Volts: 395; Continuous Volt: 395; Pick-Up Volt Min.: 260; Pick-Up Volt Max.: 275; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 120; Replaces Mars #: 19003;
Brand: MARS Mfg #: 19003

Turbo Easy-Start Hard Start B21-012
Turbo Easy-Start Hard Start
Volts: 330VAC; Application: Single phase compressors; HP: No Limitations; Compressor: Residential & Light Commercial; Starting Torque: 500%; Mfd: Up to 1 Ton (108-130MFD) 1-2 Ton (189-227MFD) 2.5-3 Ton (233-280MFD) 3.5-5 Ton (270-324MFD);
Brand: MARS Mfg #: 12600

Potential Relay Universal Replacement B13-309
Potential Relay Universal Replacement
Volts: 332; Continuous Volt: 332; Pick-Up Volt Min.: 168; Pick-Up Volt Max.: 182; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 90; Replaces Mars #: 19004;
Brand: MARS Mfg #: 19004

Direct Replacement Relay for Copeland B13-474
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 223; Pick-Up Volt Max.: 259; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces: (0)940-0001-68;
Brand: MARS Mfg #: 16099

Potential Relay Universal Replacement B13-310
Potential Relay Universal Replacement
Volts: 395; Continuous Volt: 395; Pick-Up Volt Min.: 215; Pick-Up Volt Max.: 225; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 120; Replaces Mars #: 19005;
Brand: MARS Mfg #: 19005

Potential Relay Universal Replacement B13-307
Potential Relay Universal Replacement
Volts: 170; Continuous Volt: 170; Pick-Up Volt Min.: 139; Pick-Up Volt Max.: 153; Drop-Out Volt Min.: 20; Drop-Out Volt Max.: 55; Replaces Mars #: 19002;
Brand: MARS Mfg #: 19002

Potential Relay Universal Replacement B13-312
Potential Relay Universal Replacement
Volts: 502; Continuous Volt: 502; Pick-Up Volt Min.: 325; Pick-Up Volt Max.: 345; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 135; Replaces Mars #: 19007;
Brand: MARS Mfg #: 19007

Potential Relay Universal Replacement B13-314
Potential Relay Universal Replacement
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 212; Pick-Up Volt Max.: 232; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces Mars #: 19010;
Brand: MARS Mfg #: 19010

Potential Relay Universal Replacement B13-311
Potential Relay Universal Replacement
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 295; Pick-Up Volt Max.: 315; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 125; Replaces Mars #: 19006;
Brand: MARS Mfg #: 19006

Direct Replacement Relay for Copeland B13-550
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 195; Pick-Up Volt Max.: 224; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces: (0)940-0001-35;
Brand: MARS Mfg #: 16090

Direct Replacement Relay for Copeland B13-470
Direct Replacement Relay for Copeland
Volts: 375; Continuous Volt: 375; Pick-Up Volt Min.: 224; Pick-Up Volt Max.: 252; Drop-Out Volt Min.: 50; Drop-Out Volt Max.: 110; Replaces: (0)940-0001-54;
Brand: MARS Mfg #: 16089

R404A Compressor B86-564
R404A Compressor
HP: 3/4; Volts: 115; Phase: 1; Starting Torque: High; BtuH Capacity @ -10°F Evap.: 3,656; BtuH Capacity @ 0°F Evap.: 4,598; BtuH Capacity @ 10°F Evap.: 5,663; Mounting Centers: 6.5" x 4"; Suction Conn.: 3/8" ODF; Discharge Conn.: 1/4"; Start Capacitor: 117U5043; Relay: 117-7441; Wt. Lbs.: 30.9;…
Brand: Secop Mfg #: SC18CLX.2-1

R404A Compressor B86-562
R404A Compressor
HP: 1/2+; Volts: 115; Phase: 1; Starting Torque: High; BtuH Capacity @ -10°F Evap.: 2,466; BtuH Capacity @ 0°F Evap.: 3,299; BtuH Capacity @ 10°F Evap.: 4,260; Mounting Centers: 6.5" x 4"; Suction Conn.: 5/16" ODF; Discharge Conn.: 1/4"; Start Capacitor: 117U5023; Relay: 117U6020; Wt. Lbs.: 27.7;…
Brand: Secop Mfg #: SC12CLX.2-1

R404A Compressors B86-559
R404A Compressors
HP: 1/3+; Volts: 115; Phase: 1; Starting Torque: High; BtuH Capacity @ -10°F Evap.: 1,716; BtuH Capacity @ 0°F Evap.: 2,205; BtuH Capacity @ 10°F Evap.: 2,780; BtuH Capacity @ 20°F Evap.: 3,451; BtuH Capacity @ 25°F Evap.: 3,451; Mounting Centers: 6.5" x 4"; Suction Conn.: 5/16" ODF; Discharge…
Brand: Secop Mfg #: NF7CLX-1

R404A Compressor B86-563
R404A Compressor
HP: 3/4; Volts: 115; Phase: 1; Starting Torque: High; BtuH Capacity @ -10°F Evap.: 3,000; BtuH Capacity @ 0°F Evap.: 3,992; BtuH Capacity @ 10°F Evap.: 5,166; Mounting Centers: 6.5" x 4"; Suction Conn.: 3/8" ODF; Discharge Conn.: 1/4"; Start Capacitor: 117U5043; Relay: 117-7441; Wt. Lbs.: 30.9;…
Brand: Secop Mfg #: SC15CLX.2-1

Turbo Easy-Start Hard Start B66-697
Turbo Easy-Start Hard Start
Volts: 330VAC; Application: Single phase compressors; HP: No Limitations; Compressor: Residential & Light Commercial; Starting Torque: 500%; Mfd: Up to 1 Ton (108-130MFD) 1-2 Ton (189-227MFD) 2.5-3 Ton (233-280MFD) 3.5-5 Ton (270-324MFD);
Brand: MARS Mfg #: 12700

Potential Relay Universal Replacement B13-313
Potential Relay Universal Replacement
Volts: 253; Continuous Volt: 253; Pick-Up Volt Min.: 285; Pick-Up Volt Max.: 305; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 77; Replaces Mars #: 19009;
Brand: MARS Mfg #: 19009

Direct Replacement Relay for Copeland B13-473
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 242; Pick-Up Volt Max.: 272; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces: (0)940-0001-64;
Brand: MARS Mfg #: 16098

Direct Replacement Relay for Copeland B14-246
Direct Replacement Relay for Copeland
Volts: 332; Continuous Volt: 332; Pick-Up Volt Min.: 162; Pick-Up Volt Max.: 175; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 90; Replaces: (0)940-0001-79;
Brand: MARS Mfg #: 16152

R134A Compressors B86-551
R134A Compressors
HP: 1/3; Volts: 115; Phase: 1; Starting Torque: High; BtuH Capacity @ -10°F Evap.: 1,101; BtuH Capacity @ 0°F Evap.: 1,498; BtuH Capacity @ 10°F Evap.: 1,980; BtuH Capacity @ 20°F Evap.: 2,564; BtuH Capacity @ 25°F Evap.: 2,915; Mounting Centers: 6.5" x 4"; Suction Conn.: 5/16" ODF; Discharge…
Brand: Secop Mfg #: NF11FX-1