61 Results

Zebra Instruments, MARS, KD, Software, Training, Testing, Tools & Training, Tools, Test Instruments, Refrigeration

Medium Zebra-Gators G36-437
Medium Zebra-Gators
Description: Medium Zebra-Gators (8-Pk.);
Brand: Zebra Instruments Mfg #: ZG003

Zebra Adapter G36-430
Zebra Adapter
Description: Safety Power Adapter;
Brand: Zebra Instruments Mfg #: ZD002

Universal Zebra ECM Motor Tester S59-418
Universal Zebra ECM Motor Tester
Description: Universal ECM Motor Tester;
Brand: Zebra Instruments Mfg #: UZ-1

Small Zebra-Gators G36-436
Small Zebra-Gators
Description: Small Zebra-Gators (10-Pk.);
Brand: Zebra Instruments Mfg #: ZG002

Direct Replacement Relay for Copeland B13-471
Direct Replacement Relay for Copeland
Volts: 375; Continuous Volt: 375; Pick-Up Volt Min.: 180; Pick-Up Volt Max.: 195; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 105; Replaces: (0)940-0001-55;
Brand: MARS Mfg #: 16023

Direct Replacement Relay for Copeland B13-472
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 180; Pick-Up Volt Max.: 195; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 105; Replaces: (0)940-0001-60;
Brand: MARS Mfg #: 16091

Potential Relay Universal Replacement B13-308
Potential Relay Universal Replacement
Volts: 395; Continuous Volt: 395; Pick-Up Volt Min.: 260; Pick-Up Volt Max.: 275; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 120; Replaces Mars #: 19003;
Brand: MARS Mfg #: 19003

Universal Zebra Adapter G36-449
Universal Zebra Adapter
Description: Adapter for GE, Regal-Beloit, and GENTEQ Series 3.0 ECM Motors;
Brand: Zebra Instruments Mfg #: UZHMB

Universal Zebra Adapter G36-450
Universal Zebra Adapter
Description: Adapter for GE, Regal-Beloit, and GENTEQ X-13 and Evergreen 'AH' (but not 'IM') Series ECM Motors; Other Manufacturer's "X-Motors";
Brand: Zebra Instruments Mfg #: UZHMC

Turbo Easy-Start Hard Start B21-012
Turbo Easy-Start Hard Start
Volts: 330VAC; Application: Single phase compressors; HP: No Limitations; Compressor: Residential & Light Commercial; Starting Torque: 500%; Mfd: Up to 1 Ton (108-130MFD) 1-2 Ton (189-227MFD) 2.5-3 Ton (233-280MFD) 3.5-5 Ton (270-324MFD);
Brand: MARS Mfg #: 12600

Potential Relay Universal Replacement B13-309
Potential Relay Universal Replacement
Volts: 332; Continuous Volt: 332; Pick-Up Volt Min.: 168; Pick-Up Volt Max.: 182; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 90; Replaces Mars #: 19004;
Brand: MARS Mfg #: 19004

Direct Replacement Relay for Copeland B13-474
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 223; Pick-Up Volt Max.: 259; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces: (0)940-0001-68;
Brand: MARS Mfg #: 16099

Potential Relay Universal Replacement B13-310
Potential Relay Universal Replacement
Volts: 395; Continuous Volt: 395; Pick-Up Volt Min.: 215; Pick-Up Volt Max.: 225; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 120; Replaces Mars #: 19005;
Brand: MARS Mfg #: 19005

Universal Zebra Adapter G36-451
Universal Zebra Adapter
Description: Adapter for GE, Regal-Beloit, and GENTEQ ECM 142 Series Motors (Signal-Controlled ECM Condenser Fan Motors);
Brand: Zebra Instruments Mfg #: UZHME

Potential Relay Universal Replacement B13-307
Potential Relay Universal Replacement
Volts: 170; Continuous Volt: 170; Pick-Up Volt Min.: 139; Pick-Up Volt Max.: 153; Drop-Out Volt Min.: 20; Drop-Out Volt Max.: 55; Replaces Mars #: 19002;
Brand: MARS Mfg #: 19002

Potential Relay Universal Replacement B13-312
Potential Relay Universal Replacement
Volts: 502; Continuous Volt: 502; Pick-Up Volt Min.: 325; Pick-Up Volt Max.: 345; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 135; Replaces Mars #: 19007;
Brand: MARS Mfg #: 19007

Potential Relay Universal Replacement B13-314
Potential Relay Universal Replacement
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 212; Pick-Up Volt Max.: 232; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces Mars #: 19010;
Brand: MARS Mfg #: 19010

Potential Relay Universal Replacement B13-311
Potential Relay Universal Replacement
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 295; Pick-Up Volt Max.: 315; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 125; Replaces Mars #: 19006;
Brand: MARS Mfg #: 19006

Direct Replacement Relay for Copeland B13-550
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 195; Pick-Up Volt Max.: 224; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces: (0)940-0001-35;
Brand: MARS Mfg #: 16090

Direct Replacement Relay for Copeland B13-470
Direct Replacement Relay for Copeland
Volts: 375; Continuous Volt: 375; Pick-Up Volt Min.: 224; Pick-Up Volt Max.: 252; Drop-Out Volt Min.: 50; Drop-Out Volt Max.: 110; Replaces: (0)940-0001-54;
Brand: MARS Mfg #: 16089


X-13 Evergreen Motor Adapter Set S59-421
X-13 Evergreen Motor Adapter Set
Description: X-13 Motor Adapter Set;
Brand: Zebra Instruments Mfg #: VZH03

Large Zebra-Gators G36-444
Large Zebra-Gators
Description: Large Zebra-Gators (4-Pk.);
Brand: Zebra Instruments Mfg #: ZG004

Universal Zebra Adapter G36-448
Universal Zebra Adapter
Description: Adapter for GE, Regal-Beloit, and GENTEQ Series 1.6, 2.0, and 2.3 ECM Motors;
Brand: Zebra Instruments Mfg #: UZHMA