48 Results

Victor, RIB, MARS, KD, Software, Training, Testing, Tools & Training, Tools, Refrigeration

Oxy-Acetylene Brazing Kit H85-401
Oxy-Acetylene Brazing Kit
Brazing Nozzles: 0-W-J & 2-W-J; Braze/Weld Range: 1/4"–1-1/2"; Cutting Attachment: Y; Cutting Tip: 0-3-101; Tanks: MC & R; Tank Key: Y; Tote Case: Y;
Brand: Victor Mfg #: G150-J-CPT

Oxygen Regulator H26-092
Oxygen Regulator
Description: Regulator; Gas Type: Oxygen; High Pressure Gauge: 4,000 PSIG; Low Pressure Gauge: 100 PSIG;
Brand: Victor Mfg #: G150-60-540

Acetylene Regulator H26-091
Acetylene Regulator
Description: Regulator; Gas Type: Acetylene; High Pressure Gauge: 400 PSIG; Low Pressure Gauge: 30 PSIG;
Brand: Victor Mfg #: G150-15-200

Oxy-Acetylene Brazing Kit H85-400
Oxy-Acetylene Brazing Kit
Brazing Nozzles: 0-W-J & 2-W-J; Braze/Weld Range: 1/4"–1-1/2"; Cutting Attachment: Y; Cutting Tip: 0-3-101; Tote Case: Y;
Brand: Victor Mfg #: G150-J-CP

Oxy-Acetylene Brazing Kit H85-282
Oxy-Acetylene Brazing Kit
Brazing Nozzles: 2-W-J & 4-W-J; Braze/Weld Range: 1/2"–1-1/2"; Tanks: MC & R; Tank Key: Y;
Brand: Victor Mfg #: G150-J-APT

Oxy-Acetylene Brazing Kit H85-494
Oxy-Acetylene Brazing Kit
Brazing Nozzles: 2-W-J & 4-W-J; Braze/Weld Range: 1/2"–1-1/2";
Brand: Victor Mfg #: G150-J-AP

Oxy-Acetylene Brazing Kit H85-495
Oxy-Acetylene Brazing Kit
Brazing Nozzles: 00-W-J, 1-W-J & 3-W-J; Braze/Weld Range: 1/8"–3/4"; Cutting Attachment: Y; Cutting Tip: 0-3-101;
Brand: Victor Mfg #: G150-J-ACP

Direct Replacement Relay for Copeland B13-471
Direct Replacement Relay for Copeland
Volts: 375; Continuous Volt: 375; Pick-Up Volt Min.: 180; Pick-Up Volt Max.: 195; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 105; Replaces: (0)940-0001-55;
Brand: MARS Mfg #: 16023

Direct Replacement Relay for Copeland B13-472
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 180; Pick-Up Volt Max.: 195; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 105; Replaces: (0)940-0001-60;
Brand: MARS Mfg #: 16091

Potential Relay Universal Replacement B13-308
Potential Relay Universal Replacement
Volts: 395; Continuous Volt: 395; Pick-Up Volt Min.: 260; Pick-Up Volt Max.: 275; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 120; Replaces Mars #: 19003;
Brand: MARS Mfg #: 19003

Turbo Easy-Start Hard Start B21-012
Turbo Easy-Start Hard Start
Volts: 330VAC; Application: Single phase compressors; HP: No Limitations; Compressor: Residential & Light Commercial; Starting Torque: 500%; Mfd: Up to 1 Ton (108-130MFD) 1-2 Ton (189-227MFD) 2.5-3 Ton (233-280MFD) 3.5-5 Ton (270-324MFD);
Brand: MARS Mfg #: 12600

Potential Relay Universal Replacement B13-309
Potential Relay Universal Replacement
Volts: 332; Continuous Volt: 332; Pick-Up Volt Min.: 168; Pick-Up Volt Max.: 182; Drop-Out Volt Min.: 40; Drop-Out Volt Max.: 90; Replaces Mars #: 19004;
Brand: MARS Mfg #: 19004

Direct Replacement Relay for Copeland B13-474
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 223; Pick-Up Volt Max.: 259; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces: (0)940-0001-68;
Brand: MARS Mfg #: 16099

Replacement Acetylene Gauge H26-543
Replacement Acetylene Gauge
Description: Replacement Gauge; Gas Type: Acetylene — Contents; High Pressure Gauge: 0–400 PSIG;
Brand: Victor Mfg #: 1435-0094RP

Potential Relay Universal Replacement B13-310
Potential Relay Universal Replacement
Volts: 395; Continuous Volt: 395; Pick-Up Volt Min.: 215; Pick-Up Volt Max.: 225; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 120; Replaces Mars #: 19005;
Brand: MARS Mfg #: 19005

Potential Relay Universal Replacement B13-307
Potential Relay Universal Replacement
Volts: 170; Continuous Volt: 170; Pick-Up Volt Min.: 139; Pick-Up Volt Max.: 153; Drop-Out Volt Min.: 20; Drop-Out Volt Max.: 55; Replaces Mars #: 19002;
Brand: MARS Mfg #: 19002

Potential Relay Universal Replacement B13-312
Potential Relay Universal Replacement
Volts: 502; Continuous Volt: 502; Pick-Up Volt Min.: 325; Pick-Up Volt Max.: 345; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 135; Replaces Mars #: 19007;
Brand: MARS Mfg #: 19007

Potential Relay Universal Replacement B13-314
Potential Relay Universal Replacement
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 212; Pick-Up Volt Max.: 232; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces Mars #: 19010;
Brand: MARS Mfg #: 19010

Potential Relay Universal Replacement B13-311
Potential Relay Universal Replacement
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 295; Pick-Up Volt Max.: 315; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 125; Replaces Mars #: 19006;
Brand: MARS Mfg #: 19006

Replacement Acetylene Gauge H26-545
Replacement Acetylene Gauge
Description: Replacement Gauge; Gas Type: Acetylene — Delivery; Low Pressure Gauge: 0–30 PSIG;
Brand: Victor Mfg #: 1435-0090RP

Direct Replacement Relay for Copeland B13-550
Direct Replacement Relay for Copeland
Volts: 420; Continuous Volt: 420; Pick-Up Volt Min.: 195; Pick-Up Volt Max.: 224; Drop-Out Volt Min.: 60; Drop-Out Volt Max.: 121; Replaces: (0)940-0001-35;
Brand: MARS Mfg #: 16090


Direct Replacement Relay for Copeland B13-470
Direct Replacement Relay for Copeland
Volts: 375; Continuous Volt: 375; Pick-Up Volt Min.: 224; Pick-Up Volt Max.: 252; Drop-Out Volt Min.: 50; Drop-Out Volt Max.: 110; Replaces: (0)940-0001-54;
Brand: MARS Mfg #: 16089

Turbo Easy-Start Hard Start B66-697
Turbo Easy-Start Hard Start
Volts: 330VAC; Application: Single phase compressors; HP: No Limitations; Compressor: Residential & Light Commercial; Starting Torque: 500%; Mfd: Up to 1 Ton (108-130MFD) 1-2 Ton (189-227MFD) 2.5-3 Ton (233-280MFD) 3.5-5 Ton (270-324MFD);
Brand: MARS Mfg #: 12700
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare