126 Results

1801-3600, Oil Heat Controls, Controls, HVACR Parts, OEM Parts, Ventilation & IAQ, Refrigeration

Draft Inducer Assembly S89-811
Draft Inducer Assembly
HP: 1/50; Volts: 115; F/L Amps: 2.10; Phase: Single; RPM: 3000; Description: Draft InducerAssembly 80% - W/ Gasket 3,000 RPM 115V (Broad Ocean #Y3L248B01);
Brand: Goodman Mfg #: 0131M00002PSP

Draft Inducer Assembly S82-249
Draft Inducer Assembly
Volts: 120; F/L Amps: 2.80; Phase: Single; RPM: 3000; Description: Draft Inducer Assembly;
Brand: Goodman Mfg #: 0171M00001S

Draft Inducer Assembly S88-871
Draft Inducer Assembly
HP: 1/40; Volts: 115; F/L Amps: 1.40; Phase: Single; RPM: 3000; Rot.: CW; Description: Draft Inducer Assembly - 3000RPM 115V (Jakel #J2380-112-11258);
Brand: Goodman Mfg #: B1859005S

Draft Inducer Assembly S89-590
Draft Inducer Assembly
Volts: 115; F/L Amps: 1.80; Phase: Single; RPM: 3200; Description: Draft Inducer Assembly - 3200RPM 115V (Revcor #77-161-000);
Brand: Goodman Mfg #: B4833000S

Draft Inducer Assembly X71-333
Draft Inducer Assembly
Volts: 208-230; F/L Amps: 1.40; Phase: Single; RPM: 3000; Description: Draft Inducer Assembly - 3000 RPM 230V;
Brand: Goodman Mfg #: 0131G00000PS

Belt Drive Upblast Roof Ventilator X90-836
Belt Drive Upblast Roof Ventilator
HP: 1/4; RPM: 1819; Wheel Diam.: 10-1/2"; Max. BHP: 0.25; Sones @ 0.250" SP: 14.3; CFM @ 0.250" SP: 1,089; CFM @ 0.500" SP: 981; CFM @ 0.750" SP: 855; OEM Replacement Motor: 481477; Shipping Wt. Lbs.: 67;
Brand: Fantech Mfg #: 5BDU10BB

Belt rive Downblast Roof Ventilator X90-789
Belt rive Downblast Roof Ventilator
HP: 1/4; RPM: 1819; Wheel Diam.: 10-1/2"; Max. BHP: 0.25; Sones @ 0.250" SP: 14.2; CFM @ 0.000" SP: 1,197; CFM @ 0.250" SP: 1,104; CFM @ 0.500" SP: 1,004; CFM @ 0.750" SP: 884; CFM @ 1.250" SP: 575; OEM Replacement Motor: 481477; Shipping Wt. Lbs.: 71;
Brand: Fantech Mfg #: 5BDD10BB

Draft Inducer Assembly S89-589
Draft Inducer Assembly
Volts: 115; F/L Amps: 1.40; Phase: Single; RPM: 3000; Speeds: 1; Description: Draft Inducer Assembly - W/ Gasket 3000RPM 115V (Jakel #J238-112-11258);
Brand: Goodman Mfg #: B4059000S

1/40 VENTOR MOTOR 3200/1 S89-270
1/40 VENTOR MOTOR 3200/1
Volts: 208/230; Phase: Single; RPM: 3,200; Speeds: 1; Rot.: Clockwise End Opposite Shaft; Bearing Type: Ball; Wt. Lbs.: 3.8; NEMA Frame: 3.3; Enclosure: Open Drip Proof; OEM/OEM Mfg. #: Fasco #7121-10621; Description: 1/40 HP Motor, 3200 RPM, 1-Speed, 208/230V, Single-Phase, CW, 3.3 Frame;
Brand: Source 1 Mfg #: S1-02424115018

Duct Fan - 6" Round X83-085
Duct Fan - 6" Round
Duct Size: 6"; Max. CFM: 240; RPM: 2800; Amps: 0.64;
Brand: Diversitech Mfg #: 625-AF6

MOTOR INDUCER S81-074
MOTOR INDUCER
Volts: 208/230; Phase: Single; RPM: 3,200; Speeds: 1; Rot.: Clockwise End Opposite Shaft; Bearing Type: Ball; Wt. Lbs.: 4.0; NEMA Frame: 3.3; Enclosure: Open Drip Proof; OEM/OEM Mfg. #: York; Description: Venter Motor;
Brand: Source 1 Mfg #: S1-02435322000

Duct Fan - 8" Round X83-086
Duct Fan - 8" Round
Duct Size: 8"; Max. CFM: 420; RPM: 2800; Amps: 0.64;
Brand: Diversitech Mfg #: 625-AF8

Radon Mitigation Kits up to 1500 Sq. ft. S83-569
Radon Mitigation Kits up to 1500 Sq. ft.
Description: Mitigation Kit - 1500 Sq. ft.; Duct Size: 4"; Drive Type: Direct; RPM: 3000; Max. Amps: 1; Volts: 120; Phase: Single; Max. CFM: 166; Wt. Lbs.: 5.5; Max. Pressure: 1.7;
Brand: AprilAire Mfg #: ARN15K

Draft Inducer Assembly X80-054
Draft Inducer Assembly
HP: 1/30; Volts: 115; F/L Amps: 2.10; Phase: Single; RPM: 3000; Description: Draft Inducer Assembly 3000 RPM 115V (Jakel #J238-150-15253);
Brand: Goodman Mfg #: 20044403

SWG Power Venter - Outdoor Mounted Power Venter for Oil & Gas X89-554
SWG Power Venter - Outdoor Mounted Power Venter for Oil & Gas
Description: SWG-4HD Power Venter; Amps: 1.7; RPM: 3000; Volts: 24/115; Max. Gas BtuH Input: 170,000; Max. Oil GPH Input: 1.10;
Brand: Field Controls Mfg #: 46275400

Draft Inducer Assembly S89-604
Draft Inducer Assembly
Volts: 115; Phase: Single; RPM: 3200; Description: Draft Inducer Assembly - 3,200 RPM 115V;
Brand: Goodman Mfg #: B1859001S

SWG Power Venter - Outdoor Mounted Power Venter for Oil & Gas X89-555
SWG Power Venter - Outdoor Mounted Power Venter for Oil & Gas
Description: SWG-5 Power Venter; Amps: 1.3; RPM: 3100; Volts: 24/115; Max. Gas BtuH Input: 290,000; Max. Oil GPH Input: 1.85;
Brand: Field Controls Mfg #: 46230000

HS2 Side Wall Power Venter X81-964
HS2 Side Wall Power Venter
Description: Sidewall Vent; Amps: 1.51; RPM: 3300; Volts: 115; Duct Size: 6" to 8"; Application: Heaters; Max. Gas BtuH Input: 600,000; Wt. Lbs.: 16;
Brand: Tjernlund Products Mfg #: HS2

12" Inline Centrifugal Fan - 880 CFM @ .2" SP X82-008
12" Inline Centrifugal Fan - 880 CFM @ .2" SP
Duct Size: 12"; RPM: 2900; Max. Amps: 3.01; Max. CFM: 940;
Brand: Fantech Mfg #: FG 12XL

Draft Inducer Blower X89-891
Draft Inducer Blower
HP: 1/12; Volts: 208/230; RPM: 3200; Speeds: 1; Rot.: CCWLE; Bearing Type: Ball Bearing;
Brand: Allied Mfg #: 23G81

Draft Inducer Assembly S80-414
Draft Inducer Assembly
HP: 1/2; Volts: 115; F/L Amps: 1.40; Phase: Single; RPM: 3000; Description: Draft Inducer Assembly 3,000 RPM, 115-1-60 1.4FLA (J238-112-11258);
Brand: Goodman Mfg #: 0131F00006S

Axial Flow Fan X71-096
Axial Flow Fan
CFM: 108; Volts: 115; RPM: 3100; Amps: 0.24; Wt. Oz.: 21; Height: 4-11/16"; Width: 4-11/16"; Depth: 1-1/2"; Mounting Centers: 4-1/10";
Brand: Mechatronics Mfg #: 028420

10" Inline Mixed Flow Fan - 1187 CFM @ .25" SP X82-011
10" Inline Mixed Flow Fan - 1187 CFM @ .25" SP
Duct Size: 10"; RPM: 2850; Max. Amps: 4.84; Volts: 115; Max. CFM: 1,266;
Brand: Fantech Mfg #: FKD 10XL

VP-2F Millivolt Water Heater Venting System X89-446
VP-2F Millivolt Water Heater Venting System
Description: Sidewall Vent; Amps: 0.80; RPM: 3000; Volts: 115; Duct Size: 3" to 4"; Application: Water Heaters; Max. Gas BtuH Input: 50,000; Wt. Lbs.: 14;
Brand: Tjernlund Products Mfg #: VP-2F
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare