184 Results

230, 220, R134A, Refrigerant, Refrigeration Equipment, Refrigeration

Ice Machine Pump B84-506
Ice Machine Pump
Replaces: Ice-O-Matic; Volts: 230; Discharge Conn.: 5/8" O.D.; Wt. Lbs.: 6;
Brand: Hartell Mfg #: GPP-3MH-2P

Reach-In Unit Cooler B92-404
Reach-In Unit Cooler
Defrost: Electric; Volts: 230; Phase: 1; BtuH @ 10° TD: 2,800; BtuH @ 12° TD: 3,360; BtuH @ 15° TD: 4,200; CFM: 335; No. of Fans: 3; Fan Diam.: 5-1/2"; Width: 31-5/8"; Depth: 14-1/2"; Height: 6-3/4"; Inlet Conn.: 3/8" O.D.; Suction Conn.: 1/2" I.D.; Drain Conn.: 1/2" O.D.; Wt. Lbs.: 28;
Brand: Heatcraft Mfg #: TL28BG

Ice Machine Pump B84-507
Ice Machine Pump
Replaces: Ice-O-Matic; Volts: 230; Discharge Conn.: 5/8" O.D.; Wt. Lbs.: 6;
Brand: Hartell Mfg #: GPP-4MH-2P

Reach-In Unit Cooler B93-492
Reach-In Unit Cooler
Defrost: Electric; Volts: 230; Phase: 1; BtuH @ 10° TD: 5,300; BtuH @ 12° TD: 6,360; BtuH @ 15° TD: 7,950; CFM: 595; No. of Fans: 3; Fan Diam.: 8"; Width: 49-1/8"; Depth: 16-1/2"; Height: 6-3/4"; Inlet Conn.: 1/2" O.D.; Suction Conn.: 7/8" I.D.; Drain Conn.: 1/2" O.D.; Wt. Lbs.: 47;
Brand: Heatcraft Mfg #: TL53BG

Reach-In Unit Cooler B93-491
Reach-In Unit Cooler
Defrost: Electric; Volts: 230; Phase: 1; BtuH @ 10° TD: 3,500; BtuH @ 12° TD: 4,200; BtuH @ 15° TD: 5,250; CFM: 420; No. of Fans: 2; Fan Diam.: 8"; Width: 38-3/8"; Depth: 16-1/2"; Height: 6-3/4"; Inlet Conn.: 1/2" O.D.; Suction Conn.: 5/8" I.D.; Drain Conn.: 1/2" O.D.; Wt. Lbs.: 31;
Brand: Heatcraft Mfg #: TL35BG

Water Chiller Refrigeration Unit B96-732
Water Chiller Refrigeration Unit
Tons: 7.5; Volts: 230; Phase: 3; Min. Circuit Amps: 41.9; Max. Fuse Size: 60; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 63"; Width: 36.5"; Height: 49.25"; Shipping Wt. Lbs.: 735;
Brand: KR Products, Inc. Mfg #: WCDCR7.523

Water Chiller Refrigeration Unit B96-734
Water Chiller Refrigeration Unit
Tons: 10; Volts: 230; Phase: 3; Min. Circuit Amps: 53.6; Max. Fuse Size: 90; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 63"; Width: 36.5"; Height: 49.25"; Shipping Wt. Lbs.: 792;
Brand: KR Products, Inc. Mfg #: WCDCR1023

Water Chiller Refrigeration Unit B96-730
Water Chiller Refrigeration Unit
Tons: 5; Volts: 230; Phase: 3; Min. Circuit Amps: 27; Max. Fuse Size: 45; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 509;
Brand: KR Products, Inc. Mfg #: WCDCR523

Water Chiller Refrigeration Unit B96-726
Water Chiller Refrigeration Unit
Tons: 4; Volts: 230; Phase: 1; Min. Circuit Amps: 37.75; Max. Fuse Size: 60; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 399;
Brand: KR Products, Inc. Mfg #: WCDCR421

Water Chiller Refrigeration Unit B96-727
Water Chiller Refrigeration Unit
Tons: 4; Volts: 230; Phase: 3; Min. Circuit Amps: 24.12; Max. Fuse Size: 40; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 489;
Brand: KR Products, Inc. Mfg #: WCDCR423

Water Chiller Refrigeration Unit B96-721
Water Chiller Refrigeration Unit
Tons: 2; Volts: 230; Phase: 3; Min. Circuit Amps: 14.37; Max. Fuse Size: 20; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 358;
Brand: KR Products, Inc. Mfg #: WCDCR223

Water Chiller Refrigeration Unit B96-724
Water Chiller Refrigeration Unit
Tons: 3; Volts: 230; Phase: 3; Min. Circuit Amps: 20.12; Max. Fuse Size: 30; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 396;
Brand: KR Products, Inc. Mfg #: WCDCR323

Water Chiller Refrigeration Unit B96-723
Water Chiller Refrigeration Unit
Tons: 3; Volts: 230; Phase: 1; Min. Circuit Amps: 30; Max. Fuse Size: 50; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 409;
Brand: KR Products, Inc. Mfg #: WCDCR321

Water Chiller Refrigeration Unit B96-720
Water Chiller Refrigeration Unit
Tons: 2; Volts: 230; Phase: 1; Min. Circuit Amps: 21.5; Max. Fuse Size: 35; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 368;
Brand: KR Products, Inc. Mfg #: WCDCR221

Water Chiller Refrigeration Unit B96-729
Water Chiller Refrigeration Unit
Tons: 5; Volts: 230; Phase: 1; Min. Circuit Amps: 41.62; Max. Fuse Size: 60; Inlet Conn.: 1 NPT; Outlet Conn.: 1 NPT; Length: 54.25"; Width: 28.25"; Height: 39.5"; Shipping Wt. Lbs.: 519;
Brand: KR Products, Inc. Mfg #: WCDCR521

AWS2512ZKZXM UNIT B64-948
AWS2512ZKZXM UNIT
Volts: 220; Phase: 3;
Brand: Tecumseh Mfg #: AWS2512ZKZXM

Ice Machine Pump B84-505
Ice Machine Pump
Replaces: Ice-O-Matic; Volts: 230; Discharge Conn.: 5/8" O.D.; Wt. Lbs.: 6;
Brand: Hartell Mfg #: GPP-1MH-2P

Welded Condensing Unit E42-147
Welded Condensing Unit
Refrigerant: R134a; HP: 1/3; Volts: 220; Phase: 1; BtuH Capacity @ -10°F Evap.: 2,460; BtuH Capacity @ 0°F Evap.: 3,170; BtuH Capacity @ 10°F Evap.: 3,890; BtuH Capacity @ 15°F Evap.: 4,250; BtuH Capacity @ 20°F Evap.: 4,610; BtuH Capacity @ 25°F Evap.: 4,980; BtuH Capacity @ 30°F Evap.: 5,340;
Brand: Copeland Mfg #: M7PP-0032-IA3-179

Welded Condensing Unit E42-146
Welded Condensing Unit
Refrigerant: R134a; HP: 1/3; Volts: 220; Phase: 1; BtuH Capacity @ -10°F Evap.: 2,460; BtuH Capacity @ 0°F Evap.: 3,170; BtuH Capacity @ 10°F Evap.: 3,890; BtuH Capacity @ 15°F Evap.: 4,250; BtuH Capacity @ 20°F Evap.: 4,610; BtuH Capacity @ 25°F Evap.: 4,980; BtuH Capacity @ 30°F Evap.: 5,340;
Brand: Copeland Mfg #: M7PP-0032-IA3-177

Welded Condensing Unit E42-145
Welded Condensing Unit
Refrigerant: R134a; HP: 1/3; Volts: 220; Phase: 1; BtuH Capacity @ -10°F Evap.: 2,460; BtuH Capacity @ 0°F Evap.: 3,170; BtuH Capacity @ 10°F Evap.: 3,890; BtuH Capacity @ 15°F Evap.: 4,250; BtuH Capacity @ 20°F Evap.: 4,610; BtuH Capacity @ 25°F Evap.: 4,980; BtuH Capacity @ 30°F Evap.: 5,340;
Brand: Copeland Mfg #: M7PP-0032-IA3-078

Welded Condensing Unit E42-155
Welded Condensing Unit
Refrigerant: R134a; Volts: 220; Phase: 1; BtuH Capacity @ -10°F Evap.: 2,460; BtuH Capacity @ 0°F Evap.: 3,170; BtuH Capacity @ 10°F Evap.: 3,890; BtuH Capacity @ 15°F Evap.: 4,250; BtuH Capacity @ 20°F Evap.: 4,610; BtuH Capacity @ 25°F Evap.: 4,980; BtuH Capacity @ 30°F Evap.: 5,340;
Brand: Copeland Mfg #: M7PP-H035-IA3-078

Welded Condensing Unit E42-153
Welded Condensing Unit
Refrigerant: R134a; Volts: 220; Phase: 1; BtuH Capacity @ -10°F Evap.: 2,460; BtuH Capacity @ 0°F Evap.: 3,170; BtuH Capacity @ 10°F Evap.: 3,890; BtuH Capacity @ 15°F Evap.: 4,250; BtuH Capacity @ 20°F Evap.: 4,610; BtuH Capacity @ 25°F Evap.: 4,980; BtuH Capacity @ 30°F Evap.: 5,340;
Brand: Copeland Mfg #: M7PP-H033-IA3-078

Ice Machine Pump B81-382
Ice Machine Pump
Replaces: Crystal Tips; Volts: 230; Discharge Conn.: 1" O.D.; Wt. Lbs.: 6;
Brand: Hartell Mfg #: 803323

Welded Condensing Unit E42-185
Welded Condensing Unit
Refrigerant: R134a; HP: 1/3; Volts: 220; Phase: 1; BtuH Capacity @ -10°F Evap.: 2,460; BtuH Capacity @ 0°F Evap.: 3,170; BtuH Capacity @ 10°F Evap.: 3,890; BtuH Capacity @ 15°F Evap.: 4,250; BtuH Capacity @ 20°F Evap.: 4,610; BtuH Capacity @ 25°F Evap.: 4,980; BtuH Capacity @ 30°F Evap.: 5,340;
Brand: Copeland Mfg #: M7TP-0032-IA3-118