140 Results

4, 3-1/2, 2-1/2, 12 to 12.8

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-228
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,550; Min. Circuit Amps: 28.4; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 528;
Brand: Coleman Mfg #: PCG6B481002X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-227
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 65,000; BtuH Heating Output: 52,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,550; Min. Circuit Amps: 28.4; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 520;
Brand: Coleman Mfg #: PCG6B480652X4

Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE B64-229
Single Packaged Gas/Heat Air Conditioner LX Series, 16 SEER, Single-Phase, 4 Ton, R410A, 81% AFUE
SEER: 16; EER: 12.0; Nom. Tons: 4; BtuH Cooling: 46,000; BtuH Heating Input: 125,000; BtuH Heating Output: 101,000; Volts: 208/230; Phase: Single; Nom. CFM: 1,550; Min. Circuit Amps: 28.4; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 533;
Brand: Coleman Mfg #: PCG6B481252X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE B64-192
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,200; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 970; Min. Circuit Amps: 20.0; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 372;
Brand: Coleman Mfg #: PCG4A300752X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE B64-191
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,200; BtuH Heating Input: 50,000; BtuH Heating Output: 40,000; Volts: 208/230V; Phase: Single; Nom. CFM: 970; Min. Circuit Amps: 18.8; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 352;
Brand: Coleman Mfg #: PCG4A300502X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A B64-143
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,200; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 970; Min. Circuit Amps: 20.0; Max. Fuse Size: 30; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 343;
Brand: Coleman Mfg #: PCE4A3024

Heat Pump 20 SEER, Single-Phase, Modulating, 4 Ton, R410A B79-691
Heat Pump 20 SEER, Single-Phase, Modulating, 4 Ton, R410A
SEER: 20; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10.5; COP: 3.26; Min. Circuit Amps: 28.6; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 34-1/2"; Height: 46-1/2";…
Brand: Coleman Mfg #: HC20B4821S

Heat Pump LX Series, 14 SEER, Three-Phase, 4 Ton, R410A B79-364
Heat Pump LX Series, 14 SEER, Three-Phase, 4 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 4; HSPF: 9.00; COP: 3.58; Min. Circuit Amps: 18.42; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 235;
Brand: Coleman Mfg #: THE48B31S

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B61-262
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.3; COP: 3.86; Min. Circuit Amps: 25.5; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height:…
Brand: Coleman Mfg #: TH4B4223S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A B62-223
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 13; EER: 12; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 21.9; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 185; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC13L42B24S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3-1/2 Ton, R410A B78-421
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 17; EER: 12.75; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 23.6; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 220; OEM TXV: B19-658; OEM…
Brand: Coleman Mfg #: CC7B4221S

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-661
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.25; Nom. Tons: 4; BtuH Cooling: 46,500; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.66; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Coleman Mfg #: TH4B4822S

Heat Pump LX Series, 14 SEER, Three-Phase, 2-1/2 Ton, R410A B79-359
Heat Pump LX Series, 14 SEER, Three-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 2-1/2; HSPF: 9.00; COP: 3.36; Min. Circuit Amps: 5.93; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2"; Depth: 31-3/4"; Wt. Lbs.: 176;
Brand: Coleman Mfg #: THE30B41S

Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 4 Ton, R410A B78-422
Air Conditioning Condensing Unit LX Series, 17 SEER, Single-Phase, 4 Ton, R410A
SEER: 17; EER: 12.75; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 25.9; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth: 34-1/4"; Wt. Lbs.: 220; OEM TXV: B19-659; OEM TXV…
Brand: Coleman Mfg #: CC7B4821S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B73-975
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 149; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160301

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3-1/2 Ton, R410A B75-910
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 22.0; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 36-1/4"; Depth: 29"; Wt. Lbs.: 189; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140421

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A B75-681
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29"; Height: 38-1/4"; Depth: 29"; Wt. Lbs.: 155; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160311

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B61-297
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.00; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.3; Max. Fuse Size: 40; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4"; Depth: 29-1/4"; Wt. Lbs.: 190; OEM TXV: B19-659;…
Brand: Evcon Mfg #: RAC14L42B23S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A B61-260
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 3-1/2 Ton, R410A
EER: 12.25; Nom. Tons: 3-1/2; Volts: 208/230; Phase: Three; Min. Circuit Amps: 15.29; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD42B32S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Southwest Region Only B62-067
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 2-1/2; BtuH Cooling: 30,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 140; OEM TXV: B19-657; OEM…
Brand: Coleman Mfg #: TW4B3022S

Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A B62-864
Heat Pump LX Series, 14 SEER, Single-Phase, 2-1/2 Ton, R410A
SEER: 14; EER: 12.3; Nom. Tons: 2-1/2; BtuH Cooling: 29,000; BtuH Heating Input: 28,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.54; Min. Circuit Amps: 16.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TE4B3021S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southwest Region Only B77-436
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A, Southwest Region Only
SEER: 14; EER: 12.2; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 22.1; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659;…
Brand: Coleman Mfg #: TW4B4221S

Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A B60-663
Heat Pump LX Series, 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 9.0; COP: 3.62; Min. Circuit Amps: 30.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2"; Depth:…
Brand: Evcon Mfg #: RHP14L48B23S

Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A B62-866
Heat Pump LX Series, 14 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 14; EER: 12.0; Nom. Tons: 3-1/2; BtuH Cooling: 41,000; BtuH Heating Input: 39,000; Volts: 208/230; Phase: Single; Motor Type: PSC; HSPF: 8.2; COP: 3.52; Min. Circuit Amps: 23.5; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4";…
Brand: Coleman Mfg #: TE4B4221S