559 Results

208-230, 5, 2

5 Ton Heat Pump 14 SEER 3 Phase 208/230V B79-505
5 Ton Heat Pump 14 SEER 3 Phase 208/230V
SEER: 14; EER: 12.0; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 59,000; Volts: 208/230; Phase: Three; HSPF: 9.0; COP: 4.52; Min. Circuit Amps: 21.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 35-1/2"; Height: 34-1/4"; Depth: 35-1/2";…
Brand: Daikin Mfg #: DZ14SA0603

18 SEER Heat Pump 2 Ton B60-965
18 SEER Heat Pump 2 Ton
SEER: 18; EER: 14; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,00; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 4.26; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 10"; Depth:…
Brand: Amana Mfg #: ASZC180241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B99-212
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B74-874
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ANX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B98-350
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 184; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130601

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B73-806
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 34.3; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 211; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX130611

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B73-809
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 32.8; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 171; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX130611

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B74-879
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 57,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 29"; Height: 40"; Depth: 29"; Wt. Lbs.: 209; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX130601

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A B74-880
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 5 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 5; BtuH Cooling: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 34.5; Max. Fuse Size: 60; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 231; OEM TXV: B14-851;
Brand: Amana Mfg #: ANX130611

Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A B74-111
Air Conditioning Condensing Unit 13 SEER, Three-Phase, 5 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Three; Min. Circuit Amps: 21.3; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 301;
Brand: Daikin Mfg #: DX13SA0603

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A B66-581
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 13.4; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 125; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN3N2410

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A B66-586
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.4; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 39-1/2"; Depth: 35-1/2"; Wt. Lbs.: 227; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN3N6010

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-966
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; Nom. Tons: 5; BtuH Cooling: 55,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 33.3; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 36-1/2"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSXN406010

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-538
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 30.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-3/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for C…
Brand: Coleman Mfg #: TCE2B60S21S

Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A B65-557
Air Conditioning Condensing Unit 13.8 SEER2, Single-Phase, 5 Ton, R410A
SEER2: 13.8; EER2: 11.25; Nom. Tons: 5; BtuH Cooling: 56,000; Volts: 208/230; Phase: Single; Min. Circuit Amps: 30.9; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 34-1/4"; Height: 36-1/4"; Depth: 38"; Wt. Lbs.: 230; OEM TXV: B19-659; OEM TXV for C…
Brand: Evcon Mfg #: RAC14360B21S

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-579
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140251

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-746
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140241

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-747
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140251

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A B75-912
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.8; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8" *; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Goodman Mfg #: GSX140601

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A B76-754
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 5 Ton, R410A
SEER: 14; EER: 11.7; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 32.6; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 38-1/4"; Depth: 35-1/2"; Wt. Lbs.: 260; OEM TXV: B14-851;
Brand: Amana Mfg #: ASX140601

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-961
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 138; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-533
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 2; BtuH Cooling: 23,200; Volts: 208/230; Phase: Single; Min. Circuit Amps: 15.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-657; OEM TXV for C Series…
Brand: Coleman Mfg #: TCE2B24S21S
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.