2

18 SEER Heat Pump 2 Ton B60-965
18 SEER Heat Pump 2 Ton
SEER: 18; EER: 14; Nom. Tons: 2; BtuH Cooling: 23,800; BtuH Heating Input: 23,00; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 10; COP: 4.26; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/2"; Height: 10"; Depth:…
Brand: Amana Mfg #: ASZC180241

96% AFUE Downflow/Horizontal Gas Furnace ACES96 Series, Single-Stage, Multi-Speed, ECM L95-558
96% AFUE Downflow/Horizontal Gas Furnace ACES96 Series, Single-Stage, Multi-Speed, ECM
AFUE: 96.0%; Configuration: Downflow/Horizontal; BtuH Input: 40,000; BtuH Output: 38,440; Nom. Tons: 2; Nom. CFM: 1,200; CFM @ 0.5" ESP: 968; Min. Circuit Amps: 10.3; Vent Size: 2" - 3"; Motor Type: ECM; Width: 17-1/2"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 113; Stages: Single-Stage; LoNox: Yes;
Brand: Amana Mfg #: ACES960403BN

96% AFUE Downflow/Horizontal Gas Furnace GC9S96 Series, Single-Stage, Multi-Speed, ECM L60-511
96% AFUE Downflow/Horizontal Gas Furnace GC9S96 Series, Single-Stage, Multi-Speed, ECM
AFUE: 96.0%; Configuration: Downflow/Horizontal; BtuH Input: 40,000; BtuH Output: 38,440; Nom. Tons: 2; Nom. CFM: 1,200; CFM @ 0.5" ESP: 785; Min. Circuit Amps: 10.3; Vent Size: 2" - 3"; Motor Type: ECM; Width: 17-1/2"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 113; Stages: Single-Stage; LoNox: No;
Brand: Goodman Mfg #: GC9S960403BN

96% AFUE Downflow/Horizontal Gas Furnace GCES96 Series, Single-Stage, Multi-Speed, ECM L95-280
96% AFUE Downflow/Horizontal Gas Furnace GCES96 Series, Single-Stage, Multi-Speed, ECM
AFUE: 96.0%; Configuration: Downflow/Horizontal; BtuH Input: 40,000; BtuH Output: 38,440; Nom. Tons: 2; Nom. CFM: 1,200; CFM @ 0.5" ESP: 968; Min. Circuit Amps: 10.3; Vent Size: 2" - 3"; Motor Type: ECM; Width: 17-1/2"; Height: 34-1/2"; Depth: 28-3/4"; Wt. Lbs.: 113; Stages: Single-Stage; LoNox: No;
Brand: Goodman Mfg #: GCES960403BN

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B61-811
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 10.3; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 23"; Height: 27-1/2"; Depth: 23"; Wt. Lbs.: 103; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B99-212
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208-230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX130241

Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A B74-874
Air Conditioning Condensing Unit 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.8; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 145; OEM TXV: B18-099;
Brand: Amana Mfg #: ANX130241

Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A B66-581
Air Conditioning Condensing Unit 13.4 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 13.4; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 125; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN3N2410

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B75-907
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140241

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-579
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 14.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 27-1/2"; Depth: 26"; Wt. Lbs.: 131; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSX140251

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-746
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140241

Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A B76-747
Air Conditioning Condensing Unit 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 17.6; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 153; OEM TXV: B18-099;
Brand: Amana Mfg #: ASX140251

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-961
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.2; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 26"; Height: 32-1/2"; Depth: 26"; Wt. Lbs.: 138; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXN402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-533
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 2; BtuH Cooling: 23,200; Volts: 208/230; Phase: Single; Min. Circuit Amps: 15.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-657; OEM TXV for C Series…
Brand: Coleman Mfg #: TCE2B24S21S

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-552
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; EER2: 11.75; Nom. Tons: 2; BtuH Cooling: 23,200; Volts: 208/230; Phase: Single; Min. Circuit Amps: 15.1; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 150; OEM TXV: B19-657; OEM TXV for C Series…
Brand: Evcon Mfg #: RAC14324B21S

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-950
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 169; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXB402410

Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A B65-957
Air Conditioning Condensing Unit 14.3 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 14.3; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.4; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXM402410

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A B65-680
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 15.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 151; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXH502410

Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A B66-282
Air Conditioning Condensing Unit 15.2 SEER2, Single-Phase, 2 Ton, R410A
SEER2: 15.2; EER2: 12.5; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 16.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 140; OEM TXV: B19-657;…
Brand: Evcon Mfg #: RAC15024B21S

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B73-974
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/4"; Depth: 29"; Wt. Lbs.: 142; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX160241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B60-820
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 10.6; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32"; Depth: 29"; Wt. Lbs.: 132; OEM TXV: B18-724;
Brand: Goodman Mfg #: GSX16S241

Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A B73-981
Air Conditioning Condensing Unit 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 18.0; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29"; Height: 32-1/2"; Depth: 29"; Wt. Lbs.: 163; OEM TXV: B18-724;
Brand: Amana Mfg #: ASX160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Ton, R410A B91-179
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 12.2; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 15.7; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 32-1/2"; Depth: 29-1/4"; Wt. Lbs.: 180; OEM TXV: B18-099;
Brand: Amana Mfg #: ASXC160241

Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A B61-603
Air Conditioning Condensing Unit 16 SEER, Two-Stage, Single-Phase, 2 Tons, R410A
SEER: 16; EER: 13.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 32-1/2"; Depth: 29-1/4"; Wt. Lbs.: 180; OEM TXV: B18-099;
Brand: Goodman Mfg #: GSXC160241