69 Results

User Defined, SPST, Open on Fall, SPST Open Low, SPST/N.O., Open on Fall, SPST/Manual Reset, SPST, Breaks on Temp. Rise, Open-on-Fall, None, DPST/SPST, Analog Out

Low Pressure Control B10-528
Low Pressure Control
Switch Action: SPST Open Low; Pressure Range PSIG: 10" to 100; Diff. PSIG: 10 to 40; Conn. Size: 36" Cap. w/ Flare Nut;
Brand: Ranco Mfg #: O10-1483

Low Pressure Control B10-514
Low Pressure Control
Switch Action: SPST Open Low; Pressure Range PSIG: 12" to 50; Diff. PSIG: 5 to 35; Conn. Size: 36" Cap. w/ Flare Nut;
Brand: Ranco Mfg #: O10-1402

Pressure Control B18-812
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 20; Cutout PSI: 5; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AC-1C

Pressure Control B18-818
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 50; Cutout PSI: 25; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-12C

Aquastat® Controller L39-939
Aquastat® Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 100°F to 240°F; Diff.: Manual Reset; Insulation Depth: 3"; HC Tube: Yes;
Brand: Resideo Mfg #: L4006H1004

Pressure Control B18-824
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 90; Cutout PSI: 50; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-361C

Remote Bulb Controller L39-941
Remote Bulb Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 130°F to 270°F; Diff.: Manual Reset; HC Tube: Yes;
Brand: Resideo Mfg #: L4008E1156

Pressure Control B18-816
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 30; Cutout PSI: 15; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AC-2C

Remote Bulb Controller L39-940
Remote Bulb Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 100°F to 240°F; Diff.: 5°F to 30°F Adj.; HC Tube: No;
Brand: Resideo Mfg #: L4008A1015

Pressure Control B18-821
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 60; Cutout PSI: 35; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-2C

Pressure Control B18-814
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 25; Cutout PSI: 10; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-15C

Pressure Control B18-813
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 30; Cutout PSI: 5; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-355C

Pressure Control B18-817
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 45; Cutout PSI: 20; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-356C

Pressure Control B18-815
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 32; Cutout PSI: 10; Conn.: 48" Leads;
Brand: Johnson Controls Mfg #: P100AP-201C

Pressure Control B18-820
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 60; Cutout PSI: 30; Conn.: 78" Leads;
Brand: Johnson Controls Mfg #: P100AP-105C

Pressure Control B18-823
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 80; Cutout PSI: 40; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-357C

Special Application Temperature Control L39-491
Special Application Temperature Control
Switch Action: SPST Open Low; Range: 15°F to 55°F; Diff.: Manual Reset;
Brand: Johnson Controls Mfg #: A70HA-1C

Aquastat® Controller L39-928
Aquastat® Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 100°F to 240°F; Diff.: 5°F to 30°F Adj.; Insulation Depth: 3"; HC Tube: Yes;
Brand: Resideo Mfg #: L4006A1678

Aquastat® Controller L39-029
Aquastat® Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 130°F to 270°F; Diff.: Manual Reset; Insulation Depth: 3"; HC Tube: Yes;
Brand: Resideo Mfg #: L4006E1067

Aquastat® Controller L36-915
Aquastat® Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 100°F to 240°F; Diff.: 5°F to 30°F Adj.; Insulation Depth: 1-1/2"; HC Tube: No;
Brand: Resideo Mfg #: L4006A1017

Aquastat® Controller L36-916
Aquastat® Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 40°F to 180°F; Diff.: 2 Fixed; Insulation Depth: 1-1/2"; HC Tube: Yes;
Brand: Resideo Mfg #: L4006A1959

Aquastat® Controller L39-927
Aquastat® Controller
Switch Action: SPST, Breaks on Temp. Rise; Temp. Range: 100°F to 240°F; Diff.: 5°F Fixed; Insulation Depth: 1-1/2"; HC Tube: No;
Brand: Resideo Mfg #: L4006A1009

Pressure Control Condenser Fan Cycling Control B14-742
Pressure Control Condenser Fan Cycling Control
Application: High Pressure; Reset Type: Auto; Switch Action: SPST Open Low; Conn.: 1/4" Female Flare; Pressure Range PSIG: 100 to 465; Diff. PSIG: 25 to 85; Conn. Size: 36" Cap. w/ Flare Nut; Low Range PSIG: 100 to 465; Low Pressure Diff. PSIG: 25 to 85; High Range PSIG: 100 to 465; High Pressure…
Brand: Danfoss, Inc. Mfg #: 060-5242

Pressure Control B18-819
Pressure Control
Application: Low Pressure; Reset Type: Auto; Switch Action: SPST, Open on Fall; Cut-In PSI: 80; Cutout PSI: 25; Conn.: 18" Leads;
Brand: Johnson Controls Mfg #: P100AP-9C