Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 2 Ton, R410A B75-666
Air Conditioning Condensing Unit Horizontal Discharge, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 18.3; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 45"; Height: 37-1/4"; Depth: 20"; Wt. Lbs.: 195; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TCHD24S41S4

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-069
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Coleman Mfg #: TC3B2423S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A, Fin Tube B79-328
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A, Fin Tube
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.5; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 33-1/4"; Depth: 24"; Wt. Lbs.: 118; OEM TXV: B19-657; OEM TXV for…
Brand: Coleman Mfg #: TF3B2421S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A B77-418
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 28.5; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 165; OEM TXV: B19-659; OEM TXV…
Brand: Coleman Mfg #: TC3B4821S

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A, Fin Tube B79-332
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 4 Ton, R410A, Fin Tube
SEER: 13; EER: 11.0; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 36-1/4"; Depth: 31-3/4"; Wt. Lbs.: 210; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TF3B4821S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A B79-354
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 4; Volts: 208/230; Phase: Three; Min. Circuit Amps: 18.4; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD48B31S

Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A B79-355
Air Conditioning Condensing Unit LX Series, 13 SEER, Three-Phase, 4 Ton, R410A
SEER: 13; EER: 11.75; Nom. Tons: 4; Volts: 460; Phase: Three; Min. Circuit Amps: 8.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 31-3/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200;
Brand: Coleman Mfg #: TCD48B41S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only B77-440
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Fin Tube, Southeast Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 13.6; Max. Fuse Size: 20; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 30"; Depth: 29-1/4"; Wt. Lbs.: 131; OEM TXV: B19-657; OEM TXV…
Brand: Coleman Mfg #: TF4B2421S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only B61-252
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 2 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 14.8; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 26-3/4"; Depth: 29-1/4"; Wt. Lbs.: 135; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: TC4B2422S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only B77-430
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southeast & Northern Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TC4B4821S

Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only B77-437
Air Conditioning Condensing Unit LX Series, 14 SEER, Single-Phase, 4 Ton, R410A, Southwest Region Only
SEER: 14; EER: 11.7; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 25.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 35-1/4"; Height: 33-1/4"; Depth: 31-3/4"; Wt. Lbs.: 200; OEM TXV: B19-659; OEM…
Brand: Coleman Mfg #: TW4B4821S

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B77-284
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 2; BtuH Cooling: 23,100; BtuH Heating Input: 50,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 1.8; Nom. CFM: 800; Min. Circuit Amps: 15.8; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 394;
Brand: Coleman Mfg #: PHG4A240502X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-294
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 564;
Brand: Coleman Mfg #: PHG4B481252X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-292
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 551;
Brand: Coleman Mfg #: PHG4B480652X1

Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B77-293
Dual Fuel Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 559;
Brand: Coleman Mfg #: PHG4B481002X1

Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 2 Ton, R410A B78-406
Heat Pump LX Series, 16 SEER, Single-Phase, Modulating, 2 Ton, R410A
SEER: 16; EER: 11.75; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.8; Min. Circuit Amps: 17.2; Max. Fuse Size: 30; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 29-1/4"; Height: 33-1/4";…
Brand: Coleman Mfg #: CH16B2421S

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 208/230V B91-947
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 208/230V
SEER: 13; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: 3; Min. Circuit Amps: 21.5; Max. Fuse Size: 35; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240;
Brand: Coleman Mfg #: TCHD48S43S3

Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 460V B91-951
Horizontal Discharge Air Conditioning Condenisng Unit 13 SEER, Three-Phase, 4 Ton, R410A, 460V
SEER: 13; EER: 11.5; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 460; Phase: 3; Min. Circuit Amps: 10.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 45"; Height: 43-1/4"; Depth: 20"; Wt. Lbs.: 240;
Brand: Coleman Mfg #: TCHD48S44S3

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B64-400
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 75,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.5; Nom. CFM: 780; Min. Circuit Amps: 17.4; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 357;
Brand: Coleman Mfg #: PHG4A240752X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B64-405
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.02; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 542;
Brand: Coleman Mfg #: PHG4B481002X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B64-406
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.02; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 544;
Brand: Coleman Mfg #: PHG4B481252X4

Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A B64-142
Single Packaged Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 775; Min. Circuit Amps: 18.1; Max. Fuse Size: 25; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 307;
Brand: Coleman Mfg #: PCE4A2424

Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A B64-146
Single Packaged Air Conditioner 14 SEER, Single-Phase, 4 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 30.0; Max. Fuse Size: 45; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 431;
Brand: Coleman Mfg #: PCE4B4824

Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A B64-153
Single Packaged Air Conditioner 14 SEER, Three-Phase, 4 Ton, R410A
SEER: 14; EER: 11.2; Nom. Tons: 4; BtuH Cooling: 48,000; Volts: 208/230; Phase: Three; Motor Type: ECM; Nom. CFM: 1,560; Min. Circuit Amps: 20.2; Max. Fuse Size: 30; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 431;