52 Results

Coleman, Packaged Heat Pumps, Single Packaged Units, Residential Unitary, HVAC Equipment

Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A B64-160
Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 34,800; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,150; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 420;
Brand: Coleman Mfg #: PHE4B3624

Single Packaged Heat Pump 14 SEER, 2-1/2 Ton, Single-Phase, R410A B64-159
Single Packaged Heat Pump 14 SEER, 2-1/2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2-1/2; BtuH Cooling: 29,600; BtuH Heating Input: 28,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 950; Min. Circuit Amps: 20.5; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 355;
Brand: Coleman Mfg #: PHE4A3024

Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A B64-163
Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 485;
Brand: Coleman Mfg #: PHE4B6024

Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A B64-162
Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 46,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PHE4B4824

Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A B64-161
Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 39,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 436;
Brand: Coleman Mfg #: PHE4B4224

Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A B64-158
Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 780; Min. Circuit Amps: 18.6; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 330;
Brand: Coleman Mfg #: PHE4A2424

PHE6B3624 16S 1PH B65-659
PHE6B3624 16S 1PH
Brand: Coleman Mfg #: PHE6B3624

PHE6B6024 16S 1PH B65-661
PHE6B6024 16S 1PH
Brand: Coleman Mfg #: PHE6B6024

PHE6B4824 16S 1PH B65-660
PHE6B4824 16S 1PH
Brand: Coleman Mfg #: PHE6B4824

Single Packaged Heat Pump 16 SEER, 4 Ton, Single-Phase, R410A B79-387
Single Packaged Heat Pump 16 SEER, 4 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 4; BtuH Cooling: 47,500; BtuH Heating Input: 47,400; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,600; Min. Circuit Amps: 33.6; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 496;
Brand: Coleman Mfg #: PHE6B4821

Single Packaged Heat Pump 16 SEER, 2 Ton, Single-Phase, R410A B79-383
Single Packaged Heat Pump 16 SEER, 2 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 2; BtuH Cooling: 23,500; BtuH Heating Input: 22,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.7; Nom. CFM: 800; Min. Circuit Amps: 19.1; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 377;
Brand: Coleman Mfg #: PHE6A2421

Single Packaged Heat Pump 16 SEER, 5 Ton, Single-Phase, R410A B79-388
Single Packaged Heat Pump 16 SEER, 5 Ton, Single-Phase, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 57,200; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 42.3; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 523;
Brand: Coleman Mfg #: PHE6B6021

PHE6A2424 16S 1PH B65-658
PHE6A2424 16S 1PH
Brand: Coleman Mfg #: PHE6A2424

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3-1/2 Ton, R410A B64-404
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3-1/2 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.08; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 499;
Brand: Coleman Mfg #: PHG4B421002X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2-1/2 Ton, R410A B64-401
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2-1/2 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2-1/2; BtuH Cooling: 29,600; BtuH Heating Input: 75,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.04; Nom. CFM: 950; Min. Circuit Amps: 19.3; Refrigerant: R410A; Width: 35-3/4"; Height: 45"; Depth: 51-1/4"; Wt. Lbs.: 416;
Brand: Coleman Mfg #: PHG4A300752X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A B64-400
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 2 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 75,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.5; Nom. CFM: 780; Min. Circuit Amps: 17.4; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 357;
Brand: Coleman Mfg #: PHG4A240752X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3 Ton, R410A B64-402
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3; BtuH Cooling: 35,800; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.95; Nom. CFM: 1,150; Min. Circuit Amps: 23.9; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 477;
Brand: Coleman Mfg #: PHG4B361002X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B64-407
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 4.96; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 550;
Brand: Coleman Mfg #: PHG4B601252X4

Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A B60-887
Packaged Heat Pump 16 SEER, Single-Phase, Single-Stage, 5 Ton, R410A
SEER: 16; EER: 12.5; Nom. Tons: 5; BtuH Cooling: 57,500; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.2; COP: 3.6; Nom. CFM: 1,800; Min. Circuit Amps: 44.7; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 577;
Brand: Coleman Mfg #: PHG6B600652X1

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3-1/2 Ton, R410A B64-403
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 3-1/2 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 65,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.08; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 497;
Brand: Coleman Mfg #: PHG4B420652X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B64-405
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 100,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.02; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 542;
Brand: Coleman Mfg #: PHG4B481002X4

Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A B64-406
Packaged Heat Pump 14 SEER, Single-Phase, Single-Stage, 4 Ton, R410A
SEER: 14; EER: 11.6; Nom. Tons: 4; BtuH Cooling: 48,000; BtuH Heating Input: 125,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 5.02; Nom. CFM: 1,500; Min. Circuit Amps: 30.0; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 544;
Brand: Coleman Mfg #: PHG4B481252X4

Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A B77-231
Single Packaged Heat Pump 14 SEER, 3 Ton, Single-Phase, R410A
SEER: 14; EER: 11; Nom. Tons: 3; BtuH Cooling: 35,500; BtuH Heating Input: 33,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8; COP: 2.6; Nom. CFM: 1,200; Min. Circuit Amps: 26.4; Refrigerant: R410A; Width: 45-3/4"; Height: 49"; Depth: 51-1/4"; Wt. Lbs.: 448;
Brand: Coleman Mfg #: PHE4A3621

Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A B77-233
Single Packaged Heat Pump 14 SEER, 4 Ton, Single-Phase, R410A
SEER: 14; EER: 11; Nom. Tons: 4; BtuH Cooling: 45,500; BtuH Heating Input: 44,100; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8; COP: 3.5; Nom. CFM: 1,600; Min. Circuit Amps: 34.4; Refrigerant: R410A; Width: 45-3/4"; Height: 53"; Depth: 51-1/4"; Wt. Lbs.: 496;
Brand: Coleman Mfg #: PHE4A4821
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare