324 Results

5, 3-1/2, 2, Coleman

Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV L60-689
Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV
Nom. Tons: 3-1/2; Volts: 208/230; Nom. CFM: 1,400; CFM @ 0.5" ESP: 1,750; CFM High @ 0.3 ESP: 1,750; Min. Circuit Amps: 6.8; Amps @ 240V: 5.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 21"; Height: 56-3/4"; Depth: 21-1/2"; Wt. Lbs.: 137; Motor Type: ECM; Air Handler…
Brand: Coleman Mfg #: JHVTC42FBAC2N1

Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV B65-936
Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV
Nom. Tons: 3-1/2; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 21"; Height: 28-3/4"; Depth: 21-1/2"; Wt. Lbs.: 62; Description: Cased; Configuration: Horizontal; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Coleman Mfg #: XAHC42EBCN1

Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV B65-928
Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV
Nom. Tons: 2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 14-1/2"; Height: 23"; Depth: 21-1/2"; Wt. Lbs.: 40; Description: Cased; Configuration: Horizontal; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Coleman Mfg #: XAHA24BBAN1

Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV L60-690
Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV
Nom. Tons: 3-1/2; Volts: 208/230; Nom. CFM: 1,400; CFM @ 0.5" ESP: 1,750; CFM High @ 0.3 ESP: 1,750; Min. Circuit Amps: 6.8; Amps @ 240V: 5.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 21"; Height: 56-3/4"; Depth: 21-1/2"; Wt. Lbs.: 137; Motor Type: ECM; Air Handler…
Brand: Coleman Mfg #: JHVTC42FBCC2N1

Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV B65-943
Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 21-1/2"; Height: 37-1/4"; Depth: 21-1/2"; Wt. Lbs.: 68; Description: Cased; Configuration: Horizontal; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Coleman Mfg #: XAHC60GBCN1

Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, Flex Coil B65-586
Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, Flex Coil
Nom. Tons: 3-1/2; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 32-3/4"; Height: 24-1/2"; Depth: 21-1/2"; Wt. Lbs.: 67; Description: Cased; Configuration: Horizontal; Coil Type: Cased; TXV Included: No;
Brand: Coleman Mfg #: XAHD42EXXN1

Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV B65-948
Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 24-1/2"; Height: 37-1/4"; Depth: 21-1/2"; Wt. Lbs.: 83; Description: Cased; Configuration: Horizontal; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Coleman Mfg #: XAHD60JBCN1

Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV B65-929
Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, TXV
Nom. Tons: 2; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Width: 17-1/2"; Height: 23"; Depth: 21-1/2"; Wt. Lbs.: 38; Description: Cased; Configuration: Horizontal; Metering Device: TXV; Coil Type: Cased; TXV Included: Yes;
Brand: Coleman Mfg #: XAHB24BBAN1

Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A B61-216
Heat Pump 16 SEER, Single-Phase, 2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 2; BtuH Cooling: 24,000; BtuH Heating Input: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.22; Min. Circuit Amps: 15.5; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 35-1/4"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B2421S

Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV L60-695
Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV
Nom. Tons: 5; Volts: 208/230; Nom. CFM: 1,600; CFM @ 0.5" ESP: 2,075; CFM High @ 0.3 ESP: 2,050; Min. Circuit Amps: 6.8; Amps @ 240V: 5.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 21"; Height: 61-1/4"; Depth: 21-1/2"; Wt. Lbs.: 154; Motor Type: ECM; Air Handler Type:…
Brand: Coleman Mfg #: JHVTC60HBCC2N1

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 2 Ton, R410A B60-665
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 2 Ton, R410A
SEER: 19; EER: 15.5; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 15.3; Max. Fuse Size: 25; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 38-1/4"; Height: 40-1/4"; Depth: 34-1/2"; Wt. Lbs.: 195; OEM TXV: B20-469; OEM…
Brand: Coleman Mfg #: AC19B2421S

Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A B61-219
Heat Pump 16 SEER, Single-Phase, 3-1/2 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 42,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 28.7; Max. Fuse Size: 45; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Refrigerant: R410A; Width: 38"; Height: 39-1/2";…
Brand: Coleman Mfg #: CH6B4221S

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE B64-190
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 2 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 23,600; BtuH Heating Input: 75,000; BtuH Heating Output: 60,000; Volts: 208/230V; Phase: Single; Nom. CFM: 775; Min. Circuit Amps: 18.1; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 336;
Brand: Coleman Mfg #: PCG4A240752X4

Blower Assembly For Manufactured Housing Furnaces B82-443
Blower Assembly For Manufactured Housing Furnaces
Speeds: 1; Nom. Tons: 5; Type: Electric; Wt. Lbs.: 48;
Brand: Coleman Mfg #: 3500-7901/A

Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A B64-163
Single Packaged Heat Pump 14 SEER, 5 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 5; BtuH Cooling: 59,500; BtuH Heating Input: 56,500; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,850; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 45-3/4"; Height: 55"; Depth: 51-1/4"; Wt. Lbs.: 485;
Brand: Coleman Mfg #: PHE4B6024

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE B64-203
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 5; BtuH Cooling: 56,500; BtuH Heating Input: 125,000; BtuH Heating Output: 100,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,810; Min. Circuit Amps: 36.5; Refrigerant: R410A; Width: 35-3/4"; Height: 50"; Depth: 51-1/4"; Wt. Lbs.: 479;
Brand: Coleman Mfg #: PCG4B601252X4

Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE B64-197
Single Packaged Gas/Heat Air Conditioner 14 SEER, Single-Phase, 3.5 Ton, R410A, 81% AFUE
SEER: 14; EER: 11.2; Nom. Tons: 3-1/2; BtuH Cooling: 41,500; BtuH Heating Input: 100,000; BtuH Heating Output: 80,000; Volts: 208/230V; Phase: Single; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 35-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 402;
Brand: Coleman Mfg #: PCG4A421002X4

Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A B60-668
Air Conditioning Condensing Unit Echelon™ 19 SEER, Single-Phase, 5 Ton, R410A
SEER: 19; EER: 13.0; Nom. Tons: 5; BtuH Cooling: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; Min. Circuit Amps: 31.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38-1/4"; Height: 46-1/2"; Depth: 34-1/2"; Wt. Lbs.: 295; OEM TXV: B19-659;…
Brand: Coleman Mfg #: AC19B6021S

Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, Flex Coil B65-593
Evaporator Coil Full Cased, Dedicated Horizontal, "A" Type, Flex Coil
Nom. Tons: 5; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 37-1/4"; Height: 24-1/2"; Depth: 21-1/2"; Wt. Lbs.: 83; Description: Cased; Configuration: Horizontal; Coil Type: Cased; TXV Included: No;
Brand: Coleman Mfg #: XAHD60JXXN1

Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A B61-221
Heat Pump 16 SEER, Single-Phase, 5 Ton, R410A
SEER: 16; EER: 13; Nom. Tons: 5; BtuH Cooling: 60,000; BtuH Heating Input: 60,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 9.0; COP: 3.36; Min. Circuit Amps: 32.4; Max. Fuse Size: 50; Liquid Conn.: 3/8"; Suction Fitting: 1-1/8"*; Refrigerant: R410A; Width: 38"; Height: 46"; Depth:…
Brand: Coleman Mfg #: CH6B6021S

Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A B64-161
Single Packaged Heat Pump 14 SEER, 3-1/2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 3-1/2; BtuH Cooling: 42,000; BtuH Heating Input: 39,000; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.6; Nom. CFM: 1,350; Min. Circuit Amps: 27.0; Refrigerant: R410A; Width: 45-3/4"; Height: 47"; Depth: 51-1/4"; Wt. Lbs.: 436;
Brand: Coleman Mfg #: PHE4B4224

Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV L60-692
Single-Piece Air Handler JHVT Series, Varibale-Speed, ECM, Factory Installed TXV
Nom. Tons: 3-1/2; Volts: 208/230; Nom. CFM: 2,000; CFM @ 0.5" ESP: 1,775; CFM High @ 0.3 ESP: 1,775; Min. Circuit Amps: 8.8; Amps @ 240V: 7.0; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 7/8"; Width: 24-1/2"; Height: 63"; Depth: 21-1/2"; Wt. Lbs.: 157; Motor Type: ECM; Air Handler…
Brand: Coleman Mfg #: JHVTD42FBCC2N1

Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A B62-069
Air Conditioning Condensing Unit LX Series, 13 SEER, Single-Phase, 2 Ton, R410A
SEER: 13; EER: 11.0; Nom. Tons: 2; BtuH Cooling: 24,000; Volts: 208/230; Phase: Single; Motor Type: PSC; Min. Circuit Amps: 11.4; Max. Fuse Size: 15; Liquid Conn.: 3/8"; Suction Fitting: 3/4"; Refrigerant: R410A; Width: 24"; Height: 26-3/4"; Depth: 24"; Wt. Lbs.: 130; OEM TXV: B20-469; OEM TXV for…
Brand: Coleman Mfg #: TC3B2423S

Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A B64-158
Single Packaged Heat Pump 14 SEER, 2 Ton, Single-Phase, R410A
SEER: 14; EER: 11.6; Nom. Tons: 2; BtuH Cooling: 25,000; BtuH Heating Input: 23,600; Volts: 208/230; Phase: Single; Motor Type: ECM; HSPF: 8.0; COP: 3.7; Nom. CFM: 780; Min. Circuit Amps: 18.6; Refrigerant: R410A; Width: 35-3/4"; Height: 44"; Depth: 51-1/4"; Wt. Lbs.: 330;
Brand: Coleman Mfg #: PHE4A2424
FTL Finance
Powered by Site Search powered by SLI Systems
Select products to compare.
Compare